Eaton Internal Replacement Battery Cartridge (RBC) for Select 1kVA to 1.5kVA 5P and 5PX UPS Systems, TAA

EatonSKU: 4586079

Price:
Sale price$373.61

Description

Eaton Internal Replacement Battery Cartridge (RBC) for Select 1kVA to 1.5kVA 5P and 5PX UPS Systems, TAA

Keep critical power reliable and ready with the Eaton Internal Replacement Battery Cartridge (RBC) designed for select 1kVA to 1.5kVA Eaton 5P and 5PX UPS systems. This OEM replacement battery cartridge is engineered to restore full runtime after battery wear, helping you protect sensitive equipment, minimize downtime, and maintain business continuity during outages. The RBC is compatible with a broad range of Eaton models, including the 5PX1000, 5PX1500RTUS, 5PX1500RTN, 5PX1500IRT, 5PX1500RT, and 5P1500RT, ensuring you can upgrade without replacing the entire UPS. By choosing Eaton’s original RBC, you benefit from tested performance, consistent discharge characteristics, and a seamless swap that aligns with Eaton’s strict quality standards. The RBC’s design also supports government and public sector procurement through its TAA-compliant manufacturing, making it a practical choice for enterprises with diverse sourcing requirements. Whether you’re maintaining a small office UPS or powering critical network equipment in a data room, this replacement cartridge delivers dependable, long-lasting backup power when it matters most. With a typical lifespan of three to five years under normal operating conditions, this RBC helps you plan maintenance proactively, reducing the risk of unexpected outages and costly downtime.

  • Model compatibility: Specifically designed to fit Eaton 5P and 5PX UPS systems in the 1kVA–1.5kVA range, including models 5PX1000, 5PX1500RTUS, 5PX1500RTN, 5PX1500IRT, 5PX1500RT, and 5P1500RT, ensuring a precise, plug-and-play replacement that preserves the original system performance.
  • OEM reliability and performance: As the official Eaton RBC, it matches the electrical characteristics and discharge profiles of the original battery, providing reliable runtime, predictable recharge cycles, and consistent performance under load across the system’s lifecycle.
  • Long lifespan and cost optimization: With an expected service life of approximately three to five years depending on usage and environment, this RBC reduces maintenance frequency and total cost of ownership while maintaining peak UPS protection for critical workloads.
  • Easy installation and minimal downtime: The internal RBC is designed for straightforward replacement with minimal service time. Following the manufacturer’s guidance and our installation tips, you can swap batteries quickly to restore full UPS capacity and resume normal operations with little interruption.
  • Safety, compliance, and environmental care: Built to meet rigorous safety standards and is TAA-compliant for government procurement. It includes proper safety labeling and disposal guidance to help you manage end-of-life recycling in accordance with local regulations.

Technical Details of Eaton RBC

  • Form Factor: Internal Replacement Battery Cartridge (RBC) designed to slot into compatible Eaton UPS cabinets
  • Compatibility: Eaton 5P and 5PX UPS systems in the 1kVA–1.5kVA range, including models listed in the product description
  • Lifecycle: Typical lifespan of ~3–5 years under normal operating conditions
  • Certifications: TAA-compliant manufacturing with adherence to applicable safety standards
  • Warranty: Refer to the seller’s terms; warranty coverage may vary by region and distributor

How to install Eaton RBC

  • Power down the UPS and disconnect it from all mains and protected equipment. Ensure you follow your facility’s lockout/tagout procedures and verify there is no residual charge before starting the replacement.
  • Open the UPS battery compartment following the model-specific service manual. Locate the RBC and identify the securing mechanisms and any connectors or cables that need to be disconnected prior to removal.
  • Carefully remove the existing RBC by releasing latches or fasteners, taking note of orientation and any connector alignment to ensure you install the new cartridge correctly.
  • Insert the new RBC firmly, ensuring it seats fully and engages any latches. Reattach any cables or connectors exactly as they were on the old cartridge and verify there are no loose connections.
  • Close the battery compartment, reconnect the UPS to mains and load, and perform a manufacturer-recommended self-test or diagnostics to confirm full functionality and proper battery status before returning the system to normal operation.

Frequently asked questions

  • Q: What models is this RBC compatible with? A: It is designed for select Eaton 5P and 5PX UPS systems in the 1kVA–1.5kVA range, including 5PX1000, 5PX1500RTUS, 5PX1500RTN, 5PX1500IRT, 5PX1500RT, and 5P1500RT.
  • Q: How long will the RBC last in my UPS? A: Typical battery life is about three to five years, depending on factors such as load, temperature, and cycle frequency. Regular self-tests can help you monitor health and plan replacements.
  • Q: Is installation difficult for non-professionals? A: Replacement is designed to be straightforward with proper safety precautions. Follow the steps outlined in the installation section and refer to Eaton’s service manuals for model-specific guidance.
  • Q: Does this RBC come with a warranty? A: Warranty terms vary by seller and region; consult the product page or contact the supplier for precise coverage details.
  • Q: How should I dispose of an old RBC? A: Recycle or dispose of the old battery per local regulations. Many regions offer battery recycling programs; check with waste management authorities or the retailer for guidance.