Description
Eaton Internal Replacement Battery Cartridge (RBC) for Select 8kVA to 11kVA 9PX UPS Systems and EBMs
Keep your Eaton 9PX line running reliably with a genuine Internal Replacement Battery Cartridge (RBC). This RBC is engineered to drop into compatible UPS units and extended battery modules (EBMs) without compromise, restoring peak runtime and safeguarding critical workloads during outages. Designed to support select 9PX UPS models, this replacement cartridge ensures seamless performance, OEM-grade compatibility, and a straightforward swap that minimizes downtime for your business continuity needs.
When power reliability matters, the Eaton RBC for 9PX UPS systems is a trusted upgrade that preserves the integrity of your uninterruptible power supply. It is compatible with a broad range of 9PX configurations, including 9PX8K, 9PX8KHW, 9PX8KPM, 9PX8KTF5, 9PX11K, 9PX11KHW, 9PX11KPM, 9PX11KTF11, 9PX11KTF11M, and 9PX11KTF5, as well as the 9PXEBM240RT extended battery module. This compatibility ensures you don’t need to replace an entire UPS when a single RBC replacement is all that’s required to restore peak performance. The RBC maintains Eaton’s standard of quality, safety, and reliability, making it a trusted choice for data centers, IT rooms, and any environment where power availability is critical.
- OEM-grade compatibility and coverage: This RBC is built to align perfectly with Eaton 9PX UPS models and the 9PXEBM240RT, ensuring plug-and-play installation and maximizing the lifespan of your existing UPS investment.
- Restore peak runtime and protection: Replacing the worn or degraded internal battery cartridge helps restore the designed backup duration, so critical systems stay online when commercial power is disrupted.
- Hassle-free maintenance: The RBC is a maintenance-friendly replacement option that minimizes downtime and reduces the need for full UPS replacement, saving capital expense and installation effort.
- OEM-tested safety and reliability: As an official Eaton replacement part, the RBC adheres to the original safety and performance specifications, ensuring safe operation within your UPS environment.
- Compatibility with EBMs for extended protection: In addition to 9PX UPS units, this RBC works with Eaton EBMs like the 9PXEBM240RT, enabling modular expansion of runtime for larger load profiles.
Technical Details of Eaton Internal Replacement Battery Cartridge (RBC)
- Compatibility: Compatible with select Eaton 9PX UPS models (9PX8K, 9PX8KHW, 9PX8KPM, 9PX8KTF5, 9PX11K, 9PX11KHW, 9PX11KPM, 9PX11KTF11, 9PX11KTF11M, 9PX11KTF5) and the 9PXEBM240RT Extended Battery Module.
- Replacement type: Internal Replacement Battery Cartridge (RBC) designed for seamless integration without external modules or chassis modifications.
- Function: Restores battery health and runtime, helping ensure uptime for connected loads during outages and supporting safe shutdowns during power events.
- Quality and origin: OEM-grade RBC built to Eaton specifications, tested for reliability and compatibility with Eaton UPS management features.
- Usage note: Replacing the RBC should be part of regular UPS maintenance performed by qualified personnel following applicable safety procedures.
how to install Eaton Internal Replacement Battery Cartridge
- Step 1: Power down the UPS and disconnect it from utility power and any connected loads to ensure a safe replacement environment. Verify the unit has fully shut down and is displaying no active power indicators before proceeding.
- Step 2: Open the battery compartment or access panel according to the UPS model’s service manual. Locate the existing RBC within the internal bay and ensure you have a clear workspace for the installation.
- Step 3: Disconnect any internal connectors attached to the current RBC, and carefully release the RBC from its mounting or latching mechanism, keeping components and connectors clean and free of debris.
- Step 4: Align the new Eaton RBC with the connector interface and mounting points. Gently seat the cartridge into position, ensuring any latches engage and security is confirmed before reassembling the compartment.
- Step 5: Reattach any cables or connectors, replace the access panel, and reconnect the UPS to mains power. Power on the unit and perform a self-test or health check through the UPS management interface to confirm proper operation of the RBC and overall system health.
Frequently asked questions
- Q: Which models are compatible with this Eaton RBC? A: The RBC is designed for select Eaton 9PX UPS systems including 9PX8K, 9PX8KHW, 9PX8KPM, 9PX8KTF5, 9PX11K, 9PX11KHW, 9PX11KPM, 9PX11KTF11, 9PX11KTF11M, and 9PX11KTF5, along with the 9PXEBM240RT extended battery module. If your model is listed in the compatibility note, this RBC is suitable for replacement.
- Q: Why should I replace the RBC instead of the entire UPS? A: Replacing the internal battery cartridge is a cost-effective way to restore runtime and reliability without purchasing a new UPS. It minimizes downtime and preserves your existing battery management setup, while keeping the system supported by OEM components.
- Q: How long does installation typically take? A: For trained personnel, installation is typically a straightforward process that can be completed within a short maintenance window. Duration depends on UPS access, service procedure, and required safety checks, but it is designed to be quick to minimize downtime.
- Q: Can I install the RBC myself? A: The replacement should be performed by qualified personnel following Eaton safety guidelines and the UPS service manual. Improper handling of battery modules can pose safety risks, so consult or hire a trained technician if you are not experienced with UPS maintenance.
Customer reviews
Showing - Of Reviews