Eaton Managed rack PDU, 0U, L15-30P input, 8.64 kW max, 200-240V, 24A, 10 ft cord, Three-phase, Outlets: (18) C13 Outlet grip, (6) C19 Outlet grip

EatonSKU: 4030550

Price:
Sale price$1,894.97

Description

Eaton Managed Rack PDU 0U – L15-30P Input, 8.64 kW, 200–240V, 24A, 10 ft Cord, Three-Phase, 18x C13 + 6x C19 Outlets

Elevate data center power management with Eaton’s ePDU G3 Managed technology. This 0U rack-mounted PDU is purpose-built for high-density environments where precise power control, accurate cost allocation, and proactive capacity planning are essential. With outlet-level metering that delivers billing-grade accuracy, you can measure current, voltage, power, and energy for every connected device. The results can be viewed on a bright local LCD pixel display or accessed remotely via a network connection, giving you real-time visibility and granular control. In compact 0U form, this PDU preserves valuable rack space while delivering robust three-phase power distribution to support servers, storage, switches, and other critical equipment. The combination of L15-30P input, a generous 8.64 kW maximum, and 10 ft cord makes it ideal for dense data center rows, edge deployments, and room-wide power management strategies.

  • Outlet-level metering with billing-grade accuracy — Each outlet is monitored with high-precision meters, enabling precise chargeback, accurate energy accounting, and informed capacity planning. View real-time measurements such as current, voltage, power, and energy on the local LCD pixel display or push data to your preferred management system over the network for centralized visibility and analytics.
  • Three-phase power distribution in a 0U footprint — Optimize rack density with a compact design that fits seamlessly into standard 19-inch racks. The PDU is configured for a 200–240 V supply and delivers up to 24 A, supporting a total load of up to 8.64 kW while maintaining clean, organized power distribution for multi-tenant or single-tenant data centers alike.
  • Flexible outlets for diverse equipment — With 18 C13 outlets and 6 C19 outlets, this PDU accommodates a wide range of IT devices, from high-performance servers and storage arrays to network gear and consolidates cabling to simplify organization and airflow. The mix of outlet types helps you tailor power provisioning to device requirements and manage cable clutter more effectively.
  • Network-enabled monitoring and local visibility — Besides the local LCD pixel display that provides immediate, at-a-glance status, the PDU supports network access for remote monitoring, alerting, and control. This dual-access approach enables IT staff to monitor power usage, configure thresholds, and receive notifications even when they’re not physically near the rack.
  • Reliability, scalability, and energy governance — Engineered for reliability, this managed PDU supports load balancing and capacity planning across your IT fleet. It integrates with power management software to streamline capacity forecasting, cost allocation, and energy governance, helping you optimize uptime, reduce wasted energy, and make smarter procurement decisions.

Technical Details of Eaton Managed Rack PDU

  • Max load: 8.64 kW
  • Input: L15-30P, 200–240 V, 24 A
  • Phase: Three-phase
  • Cord length: 10 ft
  • Outlets: 18 x C13, 6 x C19
  • Rack placement: 0U
  • Metering: Outlet-level with high-accuracy billing-grade measurement
  • Display: Local LCD pixel display
  • Monitoring: Network-enabled monitoring and management

How to install Eaton Managed Rack PDU

  • Power off the affected rack and verify that the circuit can supply up to 24 A at 200–240 V and three-phase power for L15-30P input.
  • Mount the PDU into the 0U space of the rack; align mounting brackets and secure firmly following standard rack installation practices.
  • Connect the 10 ft power cord from the PDU to the appropriate L15-30P power source or distribution point that matches the 200–240 V, three-phase specification.
  • Route IT equipment power cables to the 18 C13 outlets and 6 C19 outlets, grouping devices by power requirements to support balanced load distribution across outlets.
  • Power up the rack, configure the local LCD display, and enable network connectivity to begin outlet-level metering. Set alert thresholds and integrate with your power management software for proactive monitoring and capacity planning.

Frequently asked questions

  • Q: What is the maximum power this Eaton PDU can deliver?
    A: Up to 8.64 kW across all outlets, with a 24 A current rating at 200–240 V.
  • Q: Which outlets are included?
    A: The PDU provides 18 x C13 outlets and 6 x C19 outlets for flexible device support.
  • Q: Does this PDU support outlet-level metering?
    A: Yes, it features billing-grade accuracy at the outlet level with both a local LCD display and network monitoring.
  • Q: Is the PDU compatible with three-phase data center power?
    A: Yes, it is designed for three-phase environments and is configured for L15-30P input.
  • Q: How can I monitor and manage the PDU?
    A: Monitoring is available via the local LCD pixel display and through network connectivity for remote management and alerting.