Description
The Eaton ePDU G3 Managed Rack PDU is a high-efficiency power distribution solution built for demanding data centers and IT racks. It provides precise monitoring of critical electrical parameters, enabling IT teams to track energy usage, anticipate capacity needs, and prevent outages before they happen. With a compact 2U footprint and a robust 16-outlet configuration, this PDU supports dense server deployments, networking gear, and storage in professional data centers. The L5-30P input, single-phase 120V supply, and a generous 10 ft cord offer flexible integration into standard rack cabinets, while Eaton's integrated management software helps automate alerts, track energy usage, and maintain uptime. Designed for scalable growth, this managed rack PDU delivers the visibility and control needed to optimize energy governance across modern IT environments.
- Real-time electrical monitoring: Track voltage, current, and power factor in real time, with historical data available for trend analysis and capacity planning. The ePDU G3 collects precise measurements at the distribution point, helping you spot loading imbalances and optimize rack-level energy usage to support efficient cooling and reduce waste.
- Remote control and alerting: Configure outlet-level or grouped control, receive alerts, and generate usage reports through Eaton's integrated management software. Proactive control reduces the risk of overloads and helps maintain service levels without manual on-site interventions, improving uptime and operational efficiency.
- Dense 16-outlet configuration: Outlets are arranged as (16) 5-20R, delivering ample distribution points for servers, storage, and networking gear in a single 2U footprint. This layout simplifies cabling, improves airflow, and supports scalable deployments in modern data centers while keeping cabinet clutter to a minimum.
- Flexible installation and power compatibility: The PDU uses a single-phase 120V supply with a 10 ft cord and an L5-30P input connector, providing a safe, common power source for typical IT racks. Its compact form factor fits most standard rack enclosures, while the rugged build stands up to the daily rigors of busy data centers.
- Energy efficiency and governance: By delivering detailed power metrics and enabling automated power policies, this managed PDU helps reduce energy consumption and cooling costs. IT managers gain actionable insights that translate into lower total cost of ownership and more sustainable operations across the data center.
Technical Details of Eaton Managed Rack PDU
- Product type: Managed rack PDU, 2U
- Input: L5-30P, 120V, 24A, single-phase
- Power rating: 2.88 kW maximum
- Output outlets: (16) 5-20R
- Cord length: 10 ft
- Management: Integrates with Eaton management software for monitoring and control
How to install Eaton Managed Rack PDU
- Prepare the rack: ensure you have a compatible 19-inch rack with mounting rails and space for a 2U device. Verify that the cabinet can accommodate the PDU’s depth and clearance to allow cable routing and airflow.
- Power connection: mount the PDU in the rack and connect the L5-30P plug to a dedicated 120V single-phase power circuit using appropriate wiring and circuit protection. Confirm that the supply can safely provide up to 24A continuous load.
- Device distribution: connect servers, storage, and networking gear to the 16 x 5-20R outlets. Plan cable layout to maintain clear airflow and avoid congestion that can impede cooling.
- Initial configuration: power on the rack and use Eaton’s management software to discover the PDU. Configure alert thresholds, outlet groups, and any desired power-capping or monitoring policies to match your data center’s requirements.
- Ongoing maintenance: regularly review energy analytics, update firmware as recommended by Eaton, and verify that all monitored parameters are updating correctly. Schedule periodic tests of the PDU’s remote-control features to ensure uptime and responsiveness.
Frequently asked questions
- What are the key monitoring features of the Eaton ePDU G3? Real-time voltage, current, and power factor monitoring with historical reporting and integration with Eaton’s management software for alerts and reporting.
- What outlets does this PDU provide? It provides (16) 5-20R outlets for flexible server, storage, and network device connections.
- What is the input power specification? It uses a single-phase 120V supply with an L5-30P inlet and a maximum current of 24A, up to 2.88 kW of load.
- Is the PDU compatible with Eaton management software? Yes. The PDU is designed to integrate with Eaton’s management software to monitor, control, and report on power usage across racks and appliances.
- What is the cord length? The included power cord is 10 feet long, offering flexibility in rack layouts and power source placement.