Description
Eaton Pduh20dv - 1U Power Distribution Unit
Discover a compact, enterprise-grade solution designed to streamline power delivery in data centers, server rooms, and high-density rack environments. The Eaton Pduh20dv is a 1U Power Distribution Unit that consolidates power for critical IT gear, providing a robust mix of outlets tailored to modern equipment. With 14 total outlets—12 C13 and 2 C19—this unit accommodates a wide range of devices from servers and storage to networking gear, all neatly organized within a slim 1U footprint. Its universal voltage support (100–240V) makes it suitable for global deployments, while the detachable 12-foot cord and L6-20P adapter offer flexible installation options in diverse power configurations. Built for reliability and easy integration, the Pduh20dv is backed by Eaton’s 5-year limited warranty, delivering long-term peace of mind in demanding environments.
- Versatile voltage and outlet configuration: Designed to operate across a broad voltage range (100–240 V), the Eaton Pduh20dv gives data centers the flexibility to support a variety of IT gear with a single, standardized power distribution unit. It features 14 total outlets—12 C13 for mid-range equipment such as servers and storage devices, and 2 C19 outlets to accommodate higher-power devices. This mix allows you to consolidate power distribution while keeping critical devices within easy reach in a compact 1U footprint. The arrangement simplifies cabling, improves airflow, and minimizes the clutter that can hamper maintenance and performance in dense racks.
- 1U form factor with front-access practicality: The Pduh20dv is purpose-built for standard 19-inch racks, occupying just 1U of vertical space. This slim profile frees up valuable rack real estate for additional equipment while maintaining straightforward access to outlets. A clean, organized layout supports efficient cable management and serviceability, making it an ideal choice for multi-server environments, virtualization hosts, blade chassis, and high-density networking gear. Its rugged design is intended to endure the rigors of day-to-day rack activity, ensuring dependable power delivery even in busy data center rows.
- Detachable power cord and flexible installation options: A detachable 12-foot (3.66 m) power cord provides substantial reach and flexibility for arranging devices and power sources in a variety of room layouts. The included L6-20P adapter adds compatibility with common power infrastructure encountered in data centers, enabling easy integration with suitable outlets and circuits. The C20 input on the PDU allows for a clean, standardized connection to your building power, while the detachable cord makes future reconfigurations or relocations simple and cost-effective. This combination supports removal and reconfiguration without the need for specialized tools or rewiring.
- High-quality, enterprise-grade reliability and warranty: The Eaton Pduh20dv is built to meet the demanding needs of professional IT environments. Its robust construction and trusted brand heritage come with a 5-year limited warranty, signaling Eaton’s commitment to long-term performance and support. In environments where uptime is paramount, this warranty provides coverage against manufacturing defects and performance issues, helping data centers minimize risk and reduce maintenance concerns over time. The unit’s design emphasizes reliability, with attention to consistent power distribution, quiet operation, and straightforward serviceability in rack deployments.
- Ease of use, load management, and scalable deployment: With 14 outlets distributed across C13 and C19 formats, the Pduh20dv accommodates a wide range of devices without requiring multiple PDUs or daisy-chaining. This consolidation reduces cabling complexity and simplifies asset management. The voltage compatibility ensures devices in mixed-power environments can share a common distribution point, while the compact 1U footprint supports scalable rack densities as your IT needs grow. The combination of a standard form factor, easy installation, and flexible outlet types makes this PDU a practical choice for data centers, command centers, or network closets seeking reliable, centralized power distribution in a clean, organized package.
Technical Details of Eaton Pduh20dv
- Model: Pduh20dv
- Type: Power Distribution Unit (PDU)
- Unit size: 1U
- Voltage range: 100–240 V
- Outlets total: 14 (12 x C13, 2 x C19)
- Current rating: 16 A
- Input: C20
- Power cord: Detachable 12 ft (3.66 m)
- Cord adapter: L6-20P
- Warranty: 5-year limited
How to install Eaton Pduh20dv
- Prepare the rack and space: Confirm your rack is a standard 19-inch enclosure and ensure there is adequate clearance behind and around the unit for airflow and cabling. A clean, clutter-free rack environment reduces heat buildup and makes maintenance easier over time. Since the PDU occupies 1U, plan the vertical space accordingly to leave room for cables and future growth.
- Mount the PDU securely: With the correct mounting hardware, align the PDUh20dv within the rack and secure it firmly. Tighten mounting screws evenly to avoid stress on the chassis. Proper mounting helps prevent vibration and incidental damage, which is especially important in busy data centers where racks are frequently accessed for maintenance.
- Connect the power input: Attach the detachable 12-foot power cord to the C20 input on the PDU. Use the L6-20P adapter if your outlet configuration requires it. Ensure the connection is snug and the cord has a clear, strain-free path to the power source. Avoid routing cords across fans or hot spots to preserve airflow and cooling efficiency.
- Distribute devices across outlets: Plan a balanced load by assigning devices to the 12 C13 outlets and the 2 C19 outlets. Group critical equipment on separate outlets when possible to isolate potential power issues and simplify troubleshooting. Keep high-draw devices on the C19 outlets while reserving C13 outlets for servers, storage, and networking gear with moderate power needs.
- Power on and verify operation: After connecting all devices, power the rack and verify that each outlet is delivering power. Confirm that connected equipment receives stable voltage within the 100–240 V range and monitor for any tripped breakers, unusual smells, or indicators that suggest overload. Implement a load-testing check to ensure the distribution remains within safe operating limits over time.
Frequently asked questions
- What outlets are included on the Eaton Pduh20dv? It features 14 outlets in total: 12 C13 outlets for standard IT gear and 2 C19 outlets for higher-draw devices, all housed in a compact 1U form factor to maximize rack space and efficiency.
- What voltage does it support? The PDU operates across a broad range of 100–240 V, which makes it suitable for international deployments and mixed-power environments commonly found in data centers and enterprise IT facilities.
- What is the length of the power cord? The unit ships with a detachable 12-foot (3.66-meter) power cord, providing flexibility in cable routing and placement within the rack and room layout.
- What input plug does the PDU require? The PDU uses a C20 input and is compatible with the included L6-20P adapter, enabling integration with standard data center power infrastructure.
- What is the warranty? Eaton offers a 5-year limited warranty on the Pduh20dv, underscoring the product’s reliability and the manufacturer’s commitment to long-term support.
- What amperage does the PDU support? The PDU is rated for 16 A, which supports a wide range of IT equipment while helping prevent overload of typical data center circuits when properly balanced.