Description
Eaton Powerware UPS Battery Cabinet with 8 BAT-0050
Engineered for critical environments, the Eaton Powerware UPS Battery Cabinet with 8 BAT-0050 delivers dependable backup power, scalable runtime, and streamlined service in a compact footprint. Designed to integrate seamlessly with Eaton Powerware UPS systems, this cabinet houses eight BAT-0050 battery modules that deliver reliable energy storage, long life, and low self-discharge. The enclosure emphasizes easy maintenance with accessible terminals, flexible mounting options, and a rugged construction that stands up to demanding data centers, healthcare facilities, manufacturing floors, and other mission-critical environments. When power reliability is non-negotiable, Eaton’s battery cabinet helps ensure uninterrupted operation, protecting sensitive equipment, preserving data integrity, and keeping essential services up and running during outages.
- Scalable runtime with eight BAT-0050 modules: Add or remove modules to match your backup duration needs and save on total cost of ownership while preserving peak energy density.
- Maintenance-friendly design: Easy access to battery terminals simplifies routine checks, terminal testing, and replacements without disrupting adjacent equipment or workflows.
- Flexible mounting for diverse deployments: The BAT-0050 modules are engineered to be mounted in virtually any position, offering installation versatility in racks, rooms, or specialized enclosures.
- Low self-discharge and long life: Designed to retain charge for extended periods and deliver reliable performance when needed, reducing the frequency of maintenance cycles and stocking requirements.
- Cost-per-watt-hour optimization: A balance of performance, reliability, and efficiency to maximize uptime while controlling operational expenses for data centers, hospitals, and industrial settings.
Technical Details of Eaton Powerware UPS Battery Cabinet with 8 BAT-0050
- Battery configuration: 8 BAT-0050 modules housed in a single cabinet to deliver scalable reserve energy for critical loads.
- Enclosure and construction: Rugged cabinet designed to withstand the demands of data centers and enterprise environments, with easy access for maintenance and service.
- Maintenance access: Direct access to battery terminals simplifies routine inspection, testing, and replacement procedures.
- Mounting flexibility: Modules can be oriented in multiple positions to fit diverse installation spaces and UPS configurations.
- Self-discharge characteristics: Low self-discharge design to help preserve charge during periods of non-use and between maintenance cycles.
How to install Eaton Powerware UPS Battery Cabinet with 8 BAT-0050
- Plan the installation by verifying UPS compatibility, ensuring adequate ventilation, clearance, and a stable mounting surface for the cabinet.
- Power down the UPS system and follow all safety procedures before beginning battery cabinet installation to protect personnel and equipment.
- Position the cabinet in the approved location and secure it according to the installation guidelines for your environment and enclosure type.
- Connect the eight BAT-0050 battery modules to the UPS system via the designated terminals, ensuring correct polarity and secure terminations for reliable operation.
- Perform a system power-up and battery test sequence as specified by Eaton’s installation manual, confirming proper interconnections, voltage levels, and responsive protection features.
- Document the installation, label each module clearly, and schedule regular maintenance checks to monitor terminal integrity, battery health, and overall performance.
Frequently asked questions
- Q: What is included with the Eaton Powerware UPS Battery Cabinet with 8 BAT-0050?
- A: The cabinet is designed to house eight BAT-0050 battery modules and includes mounting hardware and terminal access points needed to integrate with Eaton Powerware UPS systems.
- Q: Is the BAT-0050 battery cabinet compatible with all Eaton Powerware UPS models?
- A: The cabinet is intended for use with Eaton Powerware UPS configurations that support battery cabinets of this type; exact compatibility depends on your UPS model and firmware. Refer to the Eaton compatibility guide for your specific system.
- Q: How long can the backup runtime be extended with this cabinet?
- A: Runtime depends on the critical load, UPS capacity, and the configured number of BAT-0050 modules. The eight-module configuration provides additional reserve energy to support extended outages for essential services.
- Q: Can the battery cabinet be mounted in any orientation?
- A: Yes, the BAT-0050 modules are designed for flexible mounting in virtually any position to accommodate space constraints and installation preferences.
- Q: What maintenance is required after installation?
- A: Routine maintenance includes inspecting terminal connections for tightness and corrosion, monitoring battery health indicators, and adhering to manufacturer recommendations for periodic battery replacement and testing.