Description
Eaton Tripp Lite Series 1.4kW Single-Phase Switched Automatic Transfer Switch PDU
The Eaton Tripp Lite Series 1.4kW Single-Phase Switched Automatic Transfer Switch PDU is engineered for reliability and efficiency in critical IT environments. Designed to provide uninterrupted power to sensitive network devices, this compact 1U PDU combines dual input sources with an automatic transfer switch, ensuring seamless power transfer and distribution to essential equipment such as servers, switches, routers, and storage devices. Built for data centers, edge deployments, and busy network rooms, it delivers dependable performance in a streamlined, space-saving package.
- Dual input power with automatic transfer: This PDU accepts two 120V sources via 5-15P connectors and employs an automatic transfer switch (ATS) to switch between power sources as needed. The result is uninterrupted uptime for critical equipment even during a local outage or source instability, allowing IT teams to focus on operations rather than power management concerns.
- Eight versatile output outlets: Equipped with 8 x 5-15R outlets, this PDU provides ample, organized power distribution for a cluster of devices in a compact 1U footprint. The outlets are arranged to simplify cabling and monitoring while keeping all connected equipment within easy reach for maintenance and reconfiguration.
- Compact 1U rack-mount design for space efficiency: Encased in a 1U form factor, the PDU fits neatly into standard 19" racks, maximizing rack density in data centers and network closets. Its slim profile helps optimize precious rack space while still delivering robust power management for multiple devices.
- 1.4 kW total power capacity for reliable performance: With a 1.4 kW rating, this switched ATS PDU provides a dependable power backbone for small to medium rack deployments. It supports steady operation for essential equipment during power events and reduces the risk of overload on individual devices by consolidating power distribution in a single, well-managed unit.
- TAA-compliant for government and contractor use: Built to meet Trade Agreements Act requirements, making it suitable for procurement in educational institutions, government facilities, and other organizations that rely on compliant IT infrastructure hardware. This ensures compatibility with a wide range of purchasing programs and contracts while delivering enterprise-grade reliability.
Technical Details of Eaton Tripp Lite Series 1.4kW Single-Phase Switched Automatic Transfer Switch PDU
- Power capacity: 1.4 kW total for dependable distribution to multiple devices in a compact form factor.
- Inputs: 2 × 120 V, 5-15P connectors, 15 A each, enabling dual-source redundancy and enhanced uptime.
- Outputs: 8 × 5-15R outlets for flexible device connection and organization.
- Form factor: 1U rack-mountable design that fits standard 19" racks, preserving valuable rack space.
- Compliance: TAA-compliant, suitable for government and contractor environments.
How to install Eaton Tripp Lite Series 1.4kW Single-Phase Switched Automatic Transfer Switch PDU
- Prepare the rack and mounting: Clear the installation area and verify that the rack can accommodate a 1U PDU. Align the PDU with the mounting rails and secure it firmly to prevent movement during operations or maintenance.
- Connect power sources: Route two 120V power sources to the 2 × 5-15P inputs using properly rated power cords. Ensure both sources are de-energized during installation and that cords are routed to minimize tension and interference with airflow.
- Attach loads to outlets: Plug network equipment such as servers, switches, and storage devices into the 8 × 5-15R outlets. Group devices by power requirements and label cords for easy identification during maintenance or during transfer testing.
- Configure and test ATS operation: After wiring, power up the circuit and verify that the switched ATS automatically transfers between sources when one source becomes unavailable. Conduct a controlled power-down test to confirm a seamless handoff and return to normal operation once power is restored.
- Document and monitor: Record outlet assignments, source connections, and any load distribution details. Establish routine load checks to ensure the total power consumption remains within the 1.4 kW rating and that transfer functionality continues to operate correctly over time.
Frequently asked questions
- What is the Eaton Tripp Lite Series 1.4kW Switched ATS PDU? It is a compact, 1U rack-mountable power distribution unit that combines eight outlets with a dual-input automatic transfer switch, designed to deliver reliable power continuity for critical IT equipment in data centers and network rooms.
- What power sources does it support? It supports two 120V sources through 5-15P connectors, enabling automatic transfer between sources to maintain uptime during a power event, while distributing power to connected devices through eight 5-15R outlets.
- What devices is this PDU intended for? It is ideal for servers, switches, routers, storage devices, and other sensitive networking equipment that require dependable, uninterrupted power in small to mid-sized rack deployments.
- Is this PDU compliant with government procurement? Yes. The unit is TAA-compliant, making it suitable for government and contract-based purchases under applicable procurement rules.
- How should I monitor and maintain the PDU? Regularly check load distribution to stay within the 1.4 kW capacity, label all outlets for easy maintenance, and perform periodic ATS tests to confirm automatic transfer functionality remains ready for use during power disturbances.