Eaton Tripp Lite Series 1.5kW Single-Phase Local Metered PDU, 100-127V Outlets (13 5-15R), 5-15P Input with 6 ft. (1.83 m) Cord, 1U Rack-Mount

Tripp Lite by EatonSKU: 4140896

Price:
Sale price$159.32

Description

Eaton Tripp Lite Series 1.5kW Single-Phase Local Metered PDU

The Eaton Tripp Lite Series 1.5kW Single-Phase Local Metered PDU is a premium power distribution solution designed to optimize power management in data centers, server rooms, and rack-mounted environments. Engineered for reliability and efficiency, this 1U PDU delivers precise, in-network power distribution to critical equipment while giving you clear, actionable insight into energy usage. With 13 NEMA 5-15R outlets on a front-facing strip, a 6 ft cord, and a 5-15P input, it’s built to simplify power provisioning for a wide range of devices—from blades and racks to network switches and storage arrays. The local metering capability helps facilities managers monitor load profiles in real time, enabling smarter capacity planning, reduced energy costs, and improved uptime for high-density deployments.

  • Powerful yet compact performance: 1.5 kW (approximately 12 A at 100-127 V) delivered through 13 front-facing NEMA 5-15R outlets, designed for dense rack environments without sacrificing reliability or cable management.
  • Local metering for real-time visibility: integrated local metering monitors critical electrical parameters so data center operators can track load, anticipate circuit limits, and optimize energy usage without relying on external monitoring hardware.
  • 1U rack-mount form factor with easy accessibility: occupies a single 1U (one rack unit) height in standard 19-inch racks, providing front access to outlets while keeping rear cabling organized for streamlined maintenance and airflow.
  • Durable, ready-for-data-center build: rugged enclosure and standard 6 ft power cord (5-15P input) are designed to withstand daily rack life in busy server rooms and data centers while maintaining consistent power delivery.
  • Ideal for a broad range of applications: perfect for server rooms, network closets, telecommunications cabinets, and edge data centers where reliable power distribution and clear load visibility are essential for uptime and energy management.

Technical Details of Eaton Tripp Lite Series 1.5kW Local Metered PDU

  • Power rating: 1.5 kW (1,500 watts) maximum continuous load
  • Phase and voltage: Single-phase operation at 100–127 V
  • Outlets: 13 x NEMA 5-15R (front-access) for standard 5-15 receptacles
  • Input: 5-15P power plug with 6 ft (1.83 m) cord
  • Cable length: 6 ft (1.83 m) cord to power source
  • Form factor: 1U rack-mount unit for standard 19-inch racks
  • Metering: Local metering provides real-time electrical load information for capacity planning and energy management
  • Construction: Rugged enclosure designed for durable data center use and reliable performance

How to install Eaton Tripp Lite Series 1.5kW Local Metered PDU

  • Prepare the rack: Ensure the server rack is clean, level, and capable of supporting a 1U PDU. Verify that there is adequate clearance for front cabling and rear airflow to maintain cooling efficiency.
  • Mount the PDU: Use standard 19-inch rack screws to secure the PDU in the selected rack position. Position it for convenient front access to outlets and a clear path for cables to connect to devices.
  • Connect to the power source: Route the 6 ft cord from the PDU input (5-15P) to a suitable 120/127 V power outlet or circuit that matches the PDU’s input rating. Ensure the circuit can safely sustain the anticipated load (up to ~12 A).
  • Route and organize cables: Connect servers, switches, storage devices, and other equipment to the 13 x NEMA 5-15R outlets. Use cable management practices to minimize clutter, improve airflow, and simplify future maintenance.
  • Verify metering and power distribution: After connections are complete, verify the PDU’s local metering readings. Confirm that the expected total load is within the 1.5 kW rating and that outlets provide power to connected devices without tripping breakers.
  • Document and monitor: Record important details such as circuit availability, typical load ranges, and peak usage. If you use DCIM or facility monitoring, integrate the PDU’s local metering data into your energy management workflow for ongoing optimization.

Frequently asked questions

  • What outlets does this PDU provide? It features 13 x NEMA 5-15R outlets on the front of the unit, suitable for standard 5-15 appliances often used in servers, storage gear, and networking equipment.
  • What voltage does it operate at? The PDU is designed for single-phase operation at 100–127 volts, accommodating common data center power environments in North America.
  • Does this model have remote monitoring? This is a local metered PDU, meaning it provides built-in metering for on-site load monitoring. Remote monitoring may require additional infrastructure or compatible management solutions depending on your data center setup.
  • What is the form factor and rack compatibility? It is a 1U, 19-inch rack-mount unit, designed to fit standard server racks and provide front-access outlets for easy connection and serviceability.
  • How much load can it support? The PDU is rated for up to 1.5 kW (approximately 12 A at 100–127 V). It’s important to distribute the total load across all outlets and ensure circuit protection matches the anticipated demand.