Eaton Tripp Lite 1.5kW Local Metered PDU with ISOBAR Surge Suppression
Power up your rack with confidence using the Eaton Tripp Lite Series 1.5kW Local Metered PDU. This single-phase power distribution unit combines precise, real-time local load monitoring with premium ISOBAR surge suppression to shield critical IT gear from voltage transients and noise. Designed for data centers, server rooms, telecom closets, and lab environments, this compact 1U PDU fits neatly into standard 19-inch racks while delivering reliable, organized power distribution and visibility where you need it most. With a 15-foot cord, 5-15P plug, and 14 outlets rated for 100–127V, you gain flexible placement options and a clearer view of your electrical usage, enabling proactive power management and safer equipment operation. The result is enhanced uptime, improved energy efficiency, and simpler capacity planning for growing IT infrastructure.
- Real-time, local load monitoring: A digital display continuously reports the PDU output current (in amperes), so you can prevent circuit overloads and balance loads across circuits in real time. This visibility is essential for high-density racks, where even small imbalances can lead to performance issues or outages. By delivering live metering at the source, you can track usage trends, identify power-hungry equipment, and optimize your cooling and energy strategy.
- Premium ISOBAR surge suppression: Protect sensitive equipment with network-grade ISOBAR surge suppression engineered to absorb Transient Voltage Surge Suppression (TVSS) events. The rugged design helps reduce electrical noise and transient spikes, shielding servers, network switches, storage devices, and other critical gear from damage and performance degradation caused by power disturbances. With robust 3840 joules of protection, this PDU provides a strong line of defense in fluctuating environments.
- Versatile outlet and cord configuration: Outfitted with fourteen 5-15R outlets (100–127V) and a 15-amp, 5-15P plug, this PDU covers the common power needs of mid-range IT equipment. The 15-foot (4.57 m) cord offers flexible placement within a rack or nearby power strip configuration, making it easy to reach a properly rated circuit without clutter. The 1U rack-mount form factor keeps your cabinet footprint compact while delivering reliable, organized power distribution.
- Rugged, rack-ready design: Built for the demands of data centers and workaday IT rooms, this PDU is a front-access, 1U rack-mount unit designed to integrate cleanly with standard 19-inch equipment racks. The lightweight yet durable enclosure provides a secure housing for power distribution while maintaining easy access for cable management, labeling, and routine maintenance. A clean, consistent power distribution setup helps optimize airflow and simplifies equipment upgrades over time.
- Intelligent, proactive energy management: By combining metered power with surge protection, you receive actionable data and proactive protection in a single, compact package. The local metering helps operators anticipate circuit overloads, plan for growth, and verify that high-demand devices receive adequate power without compromising other equipment. This translates to higher uptime, reduced risk of unplanned outages, and more predictable energy costs for your facility.
Technial Details of Eaton Tripp Lite Series 1.5kW Local Metered PDU + ISOBAR Surge Suppression
- Power rating: 1.5 kW
- Configuration: Local Metered PDU with ISOBAR surge suppression
- Outlets: 14 x 5-15R (100–127V)
- Input plug: 5-15P
- Cord length: 15 ft. (4.57 m)
- Rack compatibility: 1U rack-mount
- Surge energy rating: 3840 joules
- Metering: Real-time local current display
- Surge protection type: Network-grade ISOBAR suppression
- Voltage range: 100–127V
- Applications: Data centers, server rooms, IT closets, telecom cabinets
- Construction: Durable enclosure suitable for rack installations and cable management
How to install Eaton Tripp Lite Series 1.5kW Local Metered PDU
- Prepare your equipment rack: ensure it is a standard 19-inch rack and has the necessary clearance for access to both the rear and front of the PDU.
- Mount the PDU in the rack: use the included mounting hardware to secure the unit in a 1U space. Align the PDU with the rack rails and tighten fasteners to prevent movement during operation.
- Connect to a suitable power circuit: plug the supplied 5-15P cord into a properly rated 15A AC circuit that matches the 100–127V input specification. Verify that the circuit can handle the anticipated load.
- Link devices to outlets: distribute your IT gear across the fourteen 5-15R outlets, grouping high-draw equipment on separate circuits if possible to maintain balance and minimize in-rack heat buildup.
- Power up and verify: restore power and check the PDU’s digital local display to confirm current readings. Label cables and outlets to reflect which devices are drawing power, and monitor the load over time to prevent overloading.
Frequently asked questions
-
Q: What is a local metered PDU and how does it differ from a monitored PDU?
A: A local metered PDU provides real-time current and basic outlet-level information directly at the power strip. It does not include a built-in remote management interface. Metering is designed for immediate visibility at the rack, helping you manage loads and plan capacity on-site. -
Q: How does the ISOBAR surge suppression protect equipment?
A: ISOBAR suppression absorbs voltage transients and suppresses electrical noise, reducing the risk of damage to connected devices. The model specifies a 3840-joule rating, which indicates its capacity to dampen energy from multiple surges and spikes over time. -
Q: Which outlets are available on this PDU and what voltage do they supply?
A: The unit provides fourteen 5-15R outlets rated for 100–127V. This configuration is suitable for most standard IT equipment and helps you organize power distribution within the rack. -
Q: Can I remotely monitor or manage this PDU?
A: This specific model emphasizes local metering and on-PDU display. If remote monitoring or management is required, consider models with integrated or optional network management cards or compatible management platforms from Eaton or third-party providers. -
Q: Is the PDU compatible with standard racks and how much height does it occupy?
A: Yes. The unit is designed for standard 19-inch racks and occupies 1U of vertical space, making it suitable for compact data center racks or mixed IT environments where space is at a premium.