Description
Eaton Tripp Lite Series 1.9-3.8kW Single-Phase 120-240V Basic PDU
The Eaton Tripp Lite Series 1.9-3.8kW Single-Phase 120-240V Basic PDU is engineered to deliver reliable, scalable power distribution for critical IT environments. Ideal for data centers, server rooms, network closets, and edge deployments, this compact 1U rack-mount PDU provides flexible electrical configurations, robust outlets, and straightforward installation. Built to support high-density gear while keeping cables organized and accessible, it’s the dependable foundation your rack needs to maintain uptime and simplify daily operations. Whether you’re provisioning a new rack or upgrading an existing setup, this basic PDU delivers steady power delivery with clear visibility and ease of use.
- The PDU supports a broad voltage range and high-efficiency power delivery, handling 1.9 to 3.8 kW of load to accommodate a mix of servers, storage, switches, and other IT equipment while maintaining margin for future growth.
- Outlets are thoughtfully arranged to maximize versatility in dense racks: 14 outlets in total—12 C13 and 2 C19—providing flexible power provisioning for a wide range of devices and configurations.
- Inlet and adapters are designed for convenience: a C20 inlet ships with 5 adapters, enabling quick connection to various cabinet power feeds and streamlining cable management in crowded enclosures.
- Space-saving architecture for efficient rack use: a 1U rack-mount footprint paired with a 10 ft (3.05 m) power cord offers generous reach and excellent front access for wiring, monitoring, and maintenance.
- Built for reliability and safety in challenging IT environments: rugged construction, clear labeling, and straightforward protection features help ensure dependable operation in data centers and server rooms while simplifying serviceability.
Technical Details of Eaton Tripp Lite Series 1.9-3.8kW Single-Phase 120-240V Basic PDU
- Power rating: 1.9 to 3.8 kW (depending on configuration)
- Input voltage: 120-240V AC, single-phase
- Outlets: 14 total (12 x C13, 2 x C19)
- Inlet: C20 with 5 adapters included
- Cord length: 10 ft (3.05 m)
- Mounting: 1U rack-mount
- Product form: Basic PDU (non-metered)
- Included accessories: 5 adapters
how to install Eaton Tripp Lite Series 1.9-3.8kW Single-Phase 120-240V Basic PDU
- Prepare the rack and power source: Verify there is an available 1U slot in the rack and confirm that your facility electrical supply can support up to the PDU’s maximum load. Power down equipment in the rack before installation to ensure safety.
- Mount the PDU in the rack: Align the 1U PDU with the rack rails and secure it using the appropriate screws or fasteners recommended by your rack manufacturer. Ensure the unit sits firmly and exits are accessible for front-end cable connection and organization.
- Connect the input power: Plug the 10 ft C20 inlet cord into a suitable 120-240V power source capable of handling the anticipated load. Route the cord neatly to minimize interference with airflow and adjacent equipment, keeping it clear of fans and hot spots.
- Distribute loads across outlets: Connect IT equipment to the 14 outlets (12 x C13 and 2 x C19) with attention to balanced loads across circuits. Avoid overloading any single outlet bank and consider staggered distribution for critical devices to maximize uptime.
- Finalize labeling and verification: Label cables for easy future maintenance, re-check all connections, and power on the rack. Confirm that all outlets are delivering power and monitor for any abnormal heat or load imbalances, adjusting as needed to maintain safe operating conditions.
Frequently asked questions
- Q: What is the power capacity of this PDU? A: The PDU supports 1.9 to 3.8 kW of load, depending on configuration, providing scalable distribution for mixed IT gear.
- Q: How many outlets does it have and what types are they? A: It includes 14 outlets in total—12 C13 and 2 C19—suitable for a broad range of servers, storage, and networking equipment. The unit also features a C20 inlet with 5 adapters for flexible connections.
- Q: What voltage does this PDU operate on? A: It operates on a single-phase 120-240V AC supply, making it compatible with many data center and network closet power architectures.
- Q: Is this PDU rack-mountable? A: Yes. It is a 1U rack-mount PDU designed to fit standard IT racks and conserve front room for cable management and airflow.
- Q: Are adapters included with the PDU? A: Yes, the unit ships with 5 adapters to support connections to various cabinet power feeds and equipment requirements.