Description
Eaton Tripp Lite Series 1.92kW 120V Single-Phase ATS/Local Metered PDU
The Eaton Tripp Lite Series 1.92kW 120V Single-Phase ATS/Local Metered PDU is a premium power distribution unit designed for demanding IT environments. Built to maximize uptime, it combines robust power management with precise energy monitoring, making it ideal for data centers, server rooms, and network closets. With automatic transfer switching, dual input capability, and a rack-ready 1U footprint, this PDU delivers reliable, space-saving power distribution for critical systems while giving you clear visibility into energy usage at the point of use.
- Power reliability with an integrated Automatic Transfer Switch (ATS) to seamlessly switch between dual feeds, helping protect connected equipment from power interruptions.
- Local metering on the front panel provides real-time insight into voltage, current, and power (kW/kWh) consumption, enabling proactive power management and capacity planning.
- 16 outlets compatible with both 5-15R and 5-20R devices, offering broad compatibility for servers, networking gear, and peripherals in a compact 1U form factor.
- Flexible installation with dual input options (L5-20P and 5-20P) and 12 ft cords, suitable for diverse data center layouts and redundant power configurations.
- Space-efficient 1U rack-mount design, TAA compliant, and UL-listed for data-center-grade reliability in a compact footprint that preserves rack density.
Technical Details of Eaton Tripp Lite Series 1.92kW 120V Single-Phase ATS/Local Metered PDU
- Power capacity: 1920 Watts (16 Amps) at 120V, optimized for standard IT equipment and dense rack environments.
- Outlet configuration: 16 x 5-15R/5-20R outlets, providing compatibility with a wide range of servers, switches, storage, and network devices.
- Inputs: Dual power inputs (L5-20P and 5-20P) to support redundant feeds and improve availability in critical deployments.
- Cord length: Each input cord extends 12 feet, enabling flexible routing and separation of power sources in crowded racks.
- Mounting: 1U rack-mount enclosure designed for standard 19-inch racks, maximizing space efficiency in data centers and server rooms.
- Metering: Local front-panel metering with real-time readout of voltage, current, and power usage to simplify monitoring and capacity planning.
- Power protection features: Built-in Automatic Transfer Switch (ATS) for automatic source switching and enhanced uptime for attached equipment.
- Compliance: TAA-compliant and UL-listed, suitable for government and enterprise deployment where compliance matters.
- Environmental and safety considerations: Engineered for reliability in typical data-center environments, with design emphasis on safe operation and serviceability in a 1U foot print.
How to Install Eaton Tripp Lite Series 1.92kW 120V Single-Phase ATS/Local Metered PDU
Follow these installation steps to deploy the PDU in a standard 19-inch rack and begin utilizing its ATS and local metering features:
- Prepare the rack: Identify a suitable 19-inch rack space with adequate airflow and clearance for the 1U PDU and its connected devices. Ensure the rack is properly grounded.
- Mount the PDU: Use the provided rack mounting hardware to secure the 1U PDU to the rack rails at the desired height. Ensure it is level and firmly fastened to prevent vibration or movement.
- Connect input sources: Attach the dual power cords to the corresponding input sources (L5-20P and/or 5-20P) on separate, protected circuits. Route cables to minimize tension and interference with airflow.
- Install equipment: Connect servers, switches, and other IT devices to the 16 outlets (5-15R/5-20R). Distribute critical devices to ensure balanced load across the PDU outlets.
- Power-up and verify: Turn on the PDU and verify the front-panel local metering display shows voltage, current, and power usage. Confirm the ATS is ready to operate and will switch sources if one input fails.
- Configure and monitor: If the PDU supports user-configurable features, follow the on-panel instructions to set alarms or thresholds. Use the front-panel readout to monitor load and optimize capacity planning over time.
- Maintenance and safety: Periodically inspect cabling for wear, dust, or obstruction. Keep airflow unrestricted around the PDU and ensure cords are cleanly managed to avoid tripping hazards or accidental disconnects.
Frequently asked questions
- Q: What is an ATS/Local Metered PDU? A: An ATS (Automatic Transfer Switch) ensures uninterrupted power by automatically switching between two input sources, while local metering provides on-site measurement of voltage, current, and power usage for real-time visibility.
- Q: How many outlets does this PDU provide, and what outlet types are supported? A: It offers 16 outlets that are compatible with 5-15R and 5-20R connectors, covering a broad range of IT equipment commonly used in data centers.
- Q: What is the input configuration? A: The PDU supports dual inputs (L5-20P and 5-20P) with 12-foot cords, enabling dual-feed redundancy for improved reliability.
- Q: What is the power rating and why is it suitable for IT gear? A: The unit is rated for 1920 Watts (16 Amps) at 120V, providing ample capacity for mid-range server racks, switches, and storage devices while maintaining headroom for future growth.
- Q: Is this PDU rack-mountable and compliant? A: Yes, it is a 1U rack-mount PDU, designed for standard 19-inch racks, and is TAA-compliant and UL-listed for enterprise and government use.
- Q: How does the local metering help with data-center management? A: Front-panel metering shows real-time power metrics, aiding in load balancing, energy accounting, and capacity planning without needing external metering hardware.