Description
Eaton Tripp Lite Series 1.92kW Single-Phase Local Metered PDU with ISOBAR Surge Protection
The Eaton Tripp Lite Series 1.92kW Single-Phase Local Metered PDU with ISOBAR Surge Protection is engineered for reliability, efficiency, and versatility in demanding environments. This high-performance power distribution unit is an ideal choice for telecom racks, security systems, professional AV setups, and edge data-center deployments where real-time energy visibility and robust surge protection matter most. With a 120V supply and a capacity of 1.92 kW, it supports a broad range of devices—from network switches and servers to cameras, recorders, and audio processors—while giving facilities teams precise insight into power usage to optimize capacity and reduce downtime. The compact 0U vertical form factor saves valuable rack space, allowing you to consolidate power distribution without compromising airflow or accessibility. Equipped with ISOBAR surge protection and a 15-foot cord, this PDU is ready to handle the transient events that accompany storm activity, electrical noise, and equipment startup surges. The L5-20P input provides a secure, compliant connection to a dedicated 20A, 120V circuit, delivering stable power delivery across all connected devices. With 28 NEMA 5-15/20R outlets, you can neatly arrange a wide assortment of equipment, keeping cords organized and power distribution simple. This PDU is crafted to deliver consistent performance in demanding environments, helping you reduce maintenance costs and extend the life of critical gear.
- Local metering for real-time energy visibility — monitor voltage, current, and cumulative energy on the unit itself, enabling precise capacity planning, load balancing, and energy budgeting for future deployments.
- ISOBAR surge protection up to 3840 joules — guards connected equipment against spikes, transient events, and common power anomalies, preserving uptime and reducing the risk of damage during storms or electrical interference.
- High outlet count for flexible equipment provisioning — 28 NEMA 5-15/20R outlets provide ample ports to power multiple devices from a single, space-saving PDU, simplifying cable management in dense racks.
- Robust 120V, 1.92kW capacity with L5-20P input — designed for reliable operation on standard 120V circuits while supporting diverse loads, including servers, switches, IP cameras, and AV gear.
- 0U vertical mounting for space-saving installations — a slim footprint in standard 19" racks, enabling efficient power distribution without sacrificing rack space or airflow, ideal for telecom, security, and AV deployments.
Technical Details of Eaton Tripp Lite Series 1.92kW Single-Phase Local Metered PDU with ISOBAR Surge Protection
- Power rating: 1.92 kW at 120V (suitable for up to approximately 16A continuous load on a 120V circuit)
- Surge protection: ISOBAR-protected circuitry with a total surge energy rating of 3840 joules to guard devices against voltage transients
- Outlets: 28 NEMA 5-15/20R receptacles for flexible device connection and expandability
- Input connector: L5-20P locking input plug, designed for secure, compliant connection to a 20A, 120V power source
- Cord length: 15 ft (approximately 4.6 meters) for adaptable placement within racks and across equipment
- Mounting: 0U vertical rack-mount form factor to maximize space efficiency in standard 19" racks
- Metering: Local metering provides on-unit energy data for quick readings and capacity planning without needing external instrumentation
- Applications: Suited for telecom, security systems, AV installations, data-center edge deployments, and other environments needing reliable power distribution with monitoring and protection
How to Install Eaton Tripp Lite Series 1.92kW Local Metered PDU
- Plan placement in a compatible 19" rack, ensuring adequate clearance for cooling and accessibility. The 0U vertical design is ideal for mounting in the vertical space of the rack without consuming precious horizontal rack depth.
- Mount the PDU securely using the provided rack screws or mounting hardware appropriate for 19" racks. Align the unit so the L5-20P input is accessible from the back of the rack to minimize cable clutter.
- Connect the PDU input to a dedicated 20A, 120V circuit using the L5-20P locking plug. Verify that the circuit breaker and wiring meet local electrical codes and that the circuit can handle the anticipated load.
- Distribute loads across the 28 NEMA 5-15/20R outlets, avoiding overloading any single outlet bank. Use proper cable management to prevent pinched cords and ensure airflow around the unit.
- Power up the PDU and verify local metering readouts. Confirm that voltage, current, and energy data on the PDU reflect expected values for your connected devices.
- Check ISOBAR surge protection status and inspect for any indicator lights or fault alerts that may indicate tripped protection or wiring issues. Address any faults before placing critical equipment into production.
- Test connected equipment to ensure proper operation and verify that all devices receive stable, clean power. Periodically update or review energy usage data to optimize loads and plan future expansions.
Frequently Asked Questions
- What does Local Metered mean on this PDU? Local metering means the unit provides direct, on-device measurements of voltage, current, and energy usage. This enables quick visibility into power consumption without external meters, helping you track loads and plan capacity more accurately.
- How many outputs does the PDU provide? The unit offers 28 receptacles of NEMA 5-15/20R, giving you substantial flexibility to power multiple devices from a single distribution point.
- What surge protection is included? The PDU incorporates ISOBAR surge protection rated to approximately 3840 joules, offering robust defense against voltage spikes and transients.
- Is this compatible with typical data-center equipment? Yes. The 120V, 1.92kW rating, 0U vertical rack-mount form factor, and energy metering capabilities are well-suited for telecom gear, security cameras and recorders, AV gear, and edge servers or network devices.
- Can I install this in a standard 19" rack? Absolutely. The 0U vertical design is specifically intended for space-efficient installation in standard 19" racks, preserving horizontal space for other equipment.
- What kind of plug is used for input? The unit uses an L5-20P locking input plug, which requires a compatible 20A, 120V outlet or power distribution path.