Eaton Tripp Lite Series 2.88kW Single-Phase Local Metered PDU with ISOBAR Surge Protection
Power reliability and energy visibility converge in the Eaton Tripp Lite Series 2.88kW Single-Phase Local Metered PDU with ISOBAR Surge Protection. This compact, high-performance power distribution unit is built to manage and protect critical devices across telecom, security, and A/V installations, while delivering precise local energy metering to help you optimize usage and reduce downtime. With a 120V output, 24 NEMA 5-15/20R outlets, a robust 3840 joules surge protection rating, and a 0U vertical form factor, this PDU is designed to fit seamlessly into tight rack spaces and busy equipment rooms. The 10-foot input cord with a L5-30P plug provides flexible installation options, enabling you to place the PDU where power quality and monitoring matter most. Whether you’re outfitting a data center cabinet, a network closet, or a security suite, this Eaton Tripp Lite PDU combines smart metering, reliable surge protection, and space-saving design to help you safeguard equipment, improve energy efficiency, and simplify maintenance.
- Local metered power management: Real-time energy measurement at the PDU level provides visibility into load distribution, helping you identify power-hungry devices, optimize circuit utilization, and generate actionable energy reports for capacity planning and cost control.
- ISOBAR surge protection with high joule rating: Built-in ISOBAR surge protection delivers robust defense against dangerous transients, spikes, and power events, shielding sensitive equipment from damage and extending component life with 3840 joules of protection.
- 24 outlets for flexible load distribution: The PDU offers 24 NEMA 5-15/20R outlets at 120V, providing ample slots for servers, network gear, telecom equipment, and peripherals while maintaining orderly cable management in a rack or cabinet.
- Input and cord flexibility: A 10-foot input cord with an L5-30P plug allows easy routing from a wall outlet or pad-mounted power source, accommodating a variety of installation layouts and reducing the need for intermediate power strips.
- Space-saving 0U vertical form factor: Designed to mount in 0U vertical space, this PDU preserves valuable rack real estate, enabling denser equipment configurations and simplified cabling in data centers and network rooms.
Technical Details of Eaton Tripp Lite Series 2.88kW Single-Phase Local Metered PDU with ISOBAR Surge Protection
- PDU type: Local Metered, single-phase power distribution with energy monitoring.
- Maximum load: 2.88 kW (approximately 24 A at 120V).
- Input: 1× L5-30P, 120V input for reliable, high-performance connection.
- Output outlets: 24× NEMA 5-15R / 5-20R outlets for versatile device compatibility.
- Surge protection rating: ISOBAR surge protection with a 3840 joule rating for strong transient defense.
- Cord length: 10 ft. (3.05 m) cord to facilitate flexible installation paths.
- Form factor: 0U vertical mounting design to maximize rack space.
- Energy monitoring: Local metering to track power usage in real time and support energy-management initiatives.
how to install Eaton Tripp Lite Series 2.88kW Single-Phase Local Metered PDU with ISOBAR Surge Protection
- Prepare the installation space by confirming rack or cabinet compatibility with 0U vertical PDUs and ensuring adequate clearance for cord routing and venting.
- Mount the PDU vertically in the rack or cabinet, securing it per manufacturer guidelines to maintain stability and proper grounding.
- Connect the 10-foot input cord to the L5-30P inlet and plug the other end into a suitable 120V power source that meets local electrical codes and enclosure specifications.
- Plan load placement across the 24 outlets to balance power across circuits, avoiding overloads on any single leg and ensuring critical devices receive prioritized power.
- Power up the system and verify metering readouts on the PDU’s local display, confirm surge protection indicators are active, and perform a basic load check with representative equipment connected to the NEMA outlets.
- Document configuration details for facility maintenance, including outlet distribution, metered readings, and any alarms or indicators, and implement routine testing and monitoring as part of your data-center or network-room procedures.
Frequently asked questions
- What is the maximum load this PDU can support, and at what voltage? The Eaton Tripp Lite Series PDU is rated for up to 2.88 kW, operating at 120V, which corresponds to about 24 A of sustained current. This combination supports a broad range of devices while maintaining protection and monitoring features.
- Does this PDU provide local energy metering? Yes. It includes local metering to monitor power usage directly at the PDU, enabling quick visibility into load distribution and facilitating energy-management decisions without relying solely on external monitoring tools.
- How many outlets are available and what plug types are supported? The unit provides 24 outlets of NEMA 5-15R/5-20R configuration, suitable for typical IT and AV equipment plugs, with 120V operation for widespread compatibility.
- What level of surge protection is provided? The PDU features ISOBAR surge protection with a rating of 3840 joules, offering robust defense against transients and spikes to protect sensitive electronics connected to the outlets.
- What is the footprint and mounting style? This model uses a 0U vertical form factor, designed to maximize rack space in dense environments while allowing easy access to outlets and metering displays for service and monitoring.
- What installation considerations should I keep in mind? Ensure the power source and circuit can support the 2.88 kW load, distribute devices evenly across outlets to avoid overheating, verify grounding, and follow all local electrical codes during installation and use of the PDU.