Eaton Tripp Lite Series 2kW 100-127V Single-Phase Basic PDU - 36 NEMA 5-15/20R Outlets, L5-20P Input (5-20P Adapter), 15 ft. Cord, 72 in. 0U Rack

Tripp Lite by EatonSKU: 6047309

Price:
Sale price$275.02

Description

Eaton Tripp Lite Series 2kW Basic PDU – 36 Outlets, 100-127V, 15 ft Cord

The Eaton Tripp Lite Series 2kW 100-127V Single-Phase Basic PDU is engineered to meet the power distribution needs of data centers, computer rooms, and network closets. With a robust build and straightforward performance, this PDU provides reliable, high-capacity power distribution for essential IT infrastructure. It is designed for dependable operation in demanding environments, offering a compact, rack-friendly solution that helps you manage devices efficiently without the complexity of smart features. This is a practical choice for organizations seeking a cost-effective, durable, and easy-to-install power distribution unit that keeps servers, switches, and storage equipment running smoothly.

  • High-capacity, reliable power distribution: Supports up to 2 kW of continuous power at 100-127V single-phase, making it suitable for a wide range of servers, network gear, and storage devices. This capacity is ample for mid-sized rack deployments, letting you consolidate multiple devices onto a single common power feed while maintaining headroom for peak loads and startup surges. The basic PDU design emphasizes dependable performance with minimal complexity, helping your IT staff focus on uptime rather than managing advanced features.
  • 36 outlets for flexible device deployment: Equipped with 36 NEMA 5-15R and NEMA 5-20R outlets to accommodate mixed equipment in a compact footprint. The diverse outlet configuration supports a variety of devices from servers and blades to distribution switches and KVMs, reducing the need for additional adapters or distribution strips. With ample outlets, you can organize cables more cleanly and improve airflow in the rack, contributing to better thermal management and service life for critical components.
  • Flexible input options with a long reach: The PDU is designed for easy integration with your existing power setup, featuring an L5-20P input and an adapter option to accommodate 5-20P feeds. A generous 15-foot cord provides versatile placement, allowing you to position the PDU in a convenient location within the rack or nearby cabinet while maintaining safe routing and clearance for airflow. This flexibility makes it easier to adapt the PDU to different data center layouts without rearranging equipment.
  • Space-saving, rack-ready design: Built for 0U rack mounting, the PDU fits neatly into standard IT racks without occupying valuable rack space. The rugged construction supports steady performance in dense environments, while the compact form factor helps maximize usable rack capacity. The design emphasizes ease of installation, with mounting hardware and clear routing paths that simplify cable management and serviceability during maintenance windows or equipment swaps.
  • Simple, durable power distribution for reliable operation: As a basic, non-smart PDU, this unit focuses on delivering straightforward, robust power distribution without the potential failure points of advanced monitoring features. Its straightforward operation is ideal for data centers, computer rooms, and network closets that require predictable power delivery with minimal setup and low maintenance costs. This PDU prioritizes reliability and longevity, supporting continuous operation in mission-critical environments.

Technical Details of Eaton Tripp Lite Series 2kW 100-127V Single-Phase Basic PDU

  • Power rating: 2 kW (100-127V, single-phase) — designed to handle typical IT rack loads with headroom for startup surges and multiple devices operating simultaneously.
  • Outlets: 36 x NEMA 5-15R and 5-20R receptacles to accommodate a mix of standard IT devices and power adapters, enabling flexible device placement within the rack.
  • Input: L5-20P input with adapter option to 5-20P — supports common power feeds found in data centers and server rooms; the adapter broadens compatibility with different feed styles.
  • Cord length: 15 ft (4.57 m) — provides generous reach for convenient placement within a rack or adjacent cabinet while maintaining clean cable management.
  • Rack mounting: 0U rack-mount design designed for standard IT racks; compact footprint helps maximize usable rack space and simplifies mounting in crowded environments.
  • Rack compatibility: 72 in. 0U rack design specification referenced in product naming — suitable for integration in taller rack configurations and long-reach installations where space-saving is essential.

How to install Eaton Tripp Lite Series 2kW 100-127V Single-Phase Basic PDU

  • Plan your deployment: Confirm that your circuit can safely supply up to 2 kW and that the surrounding environment provides adequate ventilation for heat dissipation. This planning helps ensure reliable operation over time and avoids tripped breakers during peak loads.
  • Prepare the rack: Identify a suitable 0U space within your standard IT rack and gather the mounting hardware included with the PDU. Align the device with the rack rails to facilitate easy installation and future maintenance. A clean, uncluttered mounting area helps promote airflow and reduces the risk of cable strain.
  • Mount the PDU: Attach the PDU to the rack using the provided hardware. Ensure a secure fit to prevent movement during cable management and equipment changes. The 0U footprint is designed for straightforward installation without interfering with other rack components, allowing you to maximize density without compromising safety.
  • Connect input power: Plug the PDU’s 15 ft cord into a properly rated power source using the L5-20P input. If your facility uses 5-20R outlets, apply the included adapter to ensure a secure and compliant connection. Check that the connection is firm and that the cord route avoids sharp edges or high-traffic areas to reduce wear.
  • Distribute power to devices: Connect your servers, switches, storage devices, and other peripherals to the 36 NEMA outlets (5-15R/5-20R). Maintain a logical device grouping to simplify future maintenance and avoid overloading any single outlet bank. Use cable ties or Velcro straps to organize cables neatly and maintain good airflow around equipment.
  • Verify operation: After powering on, verify that all devices connected to the outlets are receiving power. Check for any unusual heat buildup and listen for abnormal fan or equipment sounds. If a circuit trips, reassess the load and distribution pattern, and adjust connections as needed to maintain safe operation.

Frequently asked questions

  • What outlets are included on this PDU? The unit provides 36 NEMA 5-15R and 5-20R outlets, enabling broad compatibility with a variety of IT equipment and adapters commonly used in data centers and server rooms.
  • What voltage and phase does it support? It operates at 100-127V in a single-phase configuration, which is common for many office-grade and data-center power feeds for mid-sized deployments.
  • Is this a managed or smart PDU? No. This is a basic PDU intended for straightforward power distribution without onboard monitoring, remote management, or environmental sensing features. It provides reliable power without additional complexity.
  • What is the input plug and cord length? The PDU uses an L5-20P input and a 15-foot cord, offering flexible placement options within your rack or adjacent cabinet while keeping the feed accessible to your power sources.
  • Does it fit standard racks? Yes. The PDU features a 0U rack-mount design suitable for standard IT racks. The product naming references a 72 in. rack compatibility in its specifications, which may correspond to a particular installation scenario or supplementary mounting context for certain configurations.