Eaton Tripp Lite Series 2kW 120V Single-Phase Basic PDU with ISOBAR Surge Protection - 3840 Joules, 14 Outlets, L5-20P Input (5-20P Adapter), 15 ft. Cord, 1U

Tripp Lite by EatonSKU: 6022214

Price:
Sale price$265.24

Description

Eaton Tripp Lite Series 2kW 120V Single-Phase Basic PDU with ISOBAR Surge Protection

The Eaton Tripp Lite Series 2kW 120V Single-Phase Basic PDU with ISOBAR Surge Protection is a purpose-built power distribution unit designed for network-grade environments. It delivers dependable, rack-ready power to multiple devices—servers, switches, routers, telecom gear, and security systems—while protecting expensive equipment from damaging surges and transients. Built in a compact 1U footprint with a 15-foot cord, this PDU provides 14 outlets on a robust chassis. The L5-20P input supports 20A circuits and can be connected directly or via adapter to suit your installation. ISOBAR surge protection rated at 3840 joules guards critical devices against spikes, making it an excellent choice for data centers, network closets, and telecom equipment rooms where reliability matters most. Whether you are outfitting a small data cabinet or expanding a larger rack, this PDU offers straightforward power distribution without unnecessary complexity.

  • High-capacity power distribution for critical IT and telecom gear: 2 kW total load capability (approximately 16.7 A at 120 V) to support multiple devices in a single 1U rack footprint.
  • Fourteen protected outlets for flexible cabling: 14 x NEMA 5-20R receptacles arranged to maximize space in tight rack environments while keeping cables organized and accessible.
  • Robust ISOBAR surge protection: 3840 joules of transient suppression deliver dependable protection against spikes, outages, and line transients that could damage sensitive equipment.
  • Flexible input and mounting: 20A L5-20P input with a 15-foot power cord; includes 1U rack-mountable steel chassis designed for quick installation in standard 19-inch racks.
  • Built for reliability in network environments: rugged construction, simple, maintenance-friendly design, and compatibility with adapters for broader deployment options, making it ideal for telecom, data centers, security systems, and small server rooms.

Technical Details of Eaton Tripp Lite Series 2kW 120V Single-Phase Basic PDU with ISOBAR Surge Protection

  • Power capacity: 2 kW total load (approximately 16.7 A at 120 V) to power multiple devices in a single 1U rack space.
  • Input: L5-20P connector, 120 V, 20 A rating; long 15 ft cord for versatile placement within a rack or cabinet.
  • Outlets: 14 x NEMA 5-20R receptacles for convenient, high-capacity distribution to network and telecom devices.
  • Surge protection: ISOBAR protection rated at 3840 joules to guard against surges and transient events.
  • Form factor: 1U rack-mountable chassis suitable for standard 19-inch racks; sturdy steel construction with mounting ears for secure installation.
  • Adapter compatibility: Designed to work with adapters for 5-20P outlets to accommodate various installation environments and power sources.

how to install Eaton Tripp Lite Series 2kW 120V Single-Phase Basic PDU with ISOBAR Surge Protection

  • Plan the installation by selecting a suitable 19-inch rack with enough clearance for airflow and cable management, and verify that the circuit you plan to use can safely support up to 2 kW (approximately 16.7 A at 120 V).
  • Power down equipment in the rack and ensure the rack is stable and secure before mounting the PDU.
  • Mount the PDU in a 1U space using the included mounting ears or hardware. Align with the rack rails and tighten screws to secure the unit firmly in place.
  • Connect the PDU to a compliant power source using the 15-foot cord and the L5-20P input. If your installation requires a 5-20P outlet, use an appropriate adapter to connect to the L5-20P input while maintaining rated load limits.
  • Distribute devices across the 14 outlets, ensuring the total load does not exceed the circuit rating. Group mission-critical devices on separate outlets where possible to balance the load and reduce the risk of simultaneous outages.
  • Inspect all connections for tightness, organize cables to prevent obstruction of airflow, and label each outlet circuit for easy maintenance in the future. Power on gradually and verify that devices receive power and respond normally.

Frequently asked questions

  • Q: What is the primary purpose of this PDU?

    A: It distributes power to multiple devices inside a rack while providing robust surge protection, helping protect sensitive equipment from voltage transients and spikes.

  • Q: How many outlets are available on this unit?

    A: The PDU features 14 outlets (NEMA 5-20R), designed to accommodate a range of network, server, and telecom devices in a compact 1U form factor.

  • Q: What is the surge protection rating?

    A: The unit offers 3840 joules of ISOBAR surge protection, providing a strong defense against transient events and voltage spikes.

  • Q: What type of input plug does the PDU use?

    A: It uses an L5-20P input connector for 120 V, 20 A circuits. If needed, adapters can be used to connect to compatible outlets while staying within the unit’s rated load.

  • Q: Is this a rack-mountable unit?

    A: Yes. The PDU is designed for standard 19-inch racks and occupies 1U of vertical space. It includes mounting hardware for secure installation.

  • Q: Does this PDU offer remote monitoring or management?

    A: This is a basic PDU with protection features but does not include built-in remote monitoring or outlet-level management. For remote management, consider a managed PDU option.