Eaton Tripp Lite Series 2kW Single-Phase Local Metered PDU
The Eaton Tripp Lite Series 2kW Single-Phase Local Metered PDU is a purpose-built power distribution solution engineered for data centers, server rooms, and professional IT environments. With a compact 1U rack-mount design, this metered PDU delivers reliable, centralized power to critical equipment while giving you clear visibility into real-time energy usage. Designed for easy deployment in standard 19-inch racks, it provides 12 outlets operating at 100–127V, making it an ideal choice for consolidating power management in dense IT deployments. Whether you’re refreshing a rack, expanding a growing data center, or optimizing a server room, this PDU combines rugged construction, practical metering, and straightforward installation to help you manage power more efficiently and protect your investments.
At the heart of the Eaton Tripp Lite Series 2kW Local Metered PDU is a focus on dependable power distribution. The device supports a single phase and delivers up to 2 kW of usable power, which covers a broad range of servers, network gear, storage appliances, and other critical IT hardware. The local metering capability provides immediate visibility into energy consumption, helping IT teams monitor load, prevent overconsumption, and plan capacity with confidence. In modern IT environments, where energy costs and thermal management are central to operational efficiency, having an accessible power meter right at the rack can lead to smarter decisions, lower operating expenses, and improved uptime.
One of the standout advantages of this PDU is its plug-and-play simplicity. With a 6-foot cord and input options of L5-20P or 5-20P, it is easy to connect to compatible power sources in a variety of facilities. The 12 receptacles are rated for 100–127V and use the common 5-15/20R configuration, making it easy to provision a mix of IT gear without specialized adapters. The 1U form factor maximizes rack density, leaving room for additional devices and ensuring that you can scale your rack power without sacrificing floor space. The rugged, purpose-built chassis is designed to withstand the rigors of demanding data centers, server rooms, and professional IT environments, providing reliable operation even in high-density deployments.
Beyond raw power delivery, this PDU supports practical workflows in IT management. Local metering enables quick checks of current draw, voltage, and power factor at a glance, helping technicians identify surges, balance loads across outlets, and optimize cooling strategies. When you combine this with thoughtful cable management and proper load distribution, you unlock greater efficiency, reduce the risk of equipment overheating, and extend the life of critical hardware. For facilities prioritizing green IT initiatives, the PDU’s measurement capabilities can feed into energy reporting programs, supporting sustainability goals and budget-conscious operations.
For IT teams seeking a dependable, easy-to-integrate power distribution unit with built-in visibility, the Eaton Tripp Lite Series 2kW Local Metered PDU represents a thoughtful blend of form, function, and value. Its compact footprint, standard rack compatibility, and straightforward metering features make it an attractive option for data centers, colocation spaces, edge computing deployments, and professional server rooms where reliable power and clear energy metrics are essential.
- High-density, single-phase 2 kW PDU delivering dependable power distribution for rack-mounted IT equipment
- Local metering provides real-time energy usage metrics on the PDU’s built-in display for quick capacity planning
- 12 outlets at 100–127V (12 x 5-15/20R) with flexible input options (L5-20P/5-20P) and a 6 ft cord
- 1U rack-mountable design that fits standard 19-inch racks, enabling scalable, space-efficient deployments
- Rugged construction with safety features and overload protection, ideal for data centers, server rooms, and IT closets
Technical Details of Eaton Tripp Lite Series 2kW Single-Phase Local Metered PDU
- Power rating: 2 kW
- Phase: Single-Phase
- Outlets: 12 x 100–127 V receptacles (NEMA 5-15/5-20R)
- Input: L5-20P / 5-20P
- Cord length: 6 ft (1.83 m)
- Form factor: 1U rack-mount
- Metering: Local metered power distribution with built-in display
- Application: Data centers, server rooms, IT closets
- Mounting: Standard 19-inch rack compatibility
How to install Eaton Tripp Lite Series 2kW Single-Phase Local Metered PDU
- Prepare the rack by ensuring the 19-inch infrastructure is clean, level, and capable of supporting a 1U device. Confirm there is adequate airflow and clearance around the rack for cooling and cable management.
- Mount the PDU in the rack using the supplied hardware. Secure it firmly to minimize vibration and movement during equipment reconfiguration and maintenance.
- Connect the PDU input to a suitable power circuit using the included input plug (L5-20P or 5-20P). Ensure the circuit provides enough capacity to support the anticipated load without tripping protective devices.
- Bridge power to connected equipment by inserting IT devices into the 12 outlets. Arrange cables to promote airflow and minimize obstruction to front-panel meters and indicator lights.
- Power on the system and verify the built-in local meter displays accurate load readings. Perform a functional check by turning on equipment sequentially to confirm stable operation and monitor current draw as devices boot up.
Frequently asked questions
-
What outlets does this PDU provide?
It provides 12 receptacles rated for 100–127 V (NEMA 5-15/5-20R), suitable for standard IT equipment in a 1U footprint.
-
What is the input configuration?
The PDU supports an input plug of L5-20P or 5-20P and includes a 6 ft (1.83 m) cord for flexible routing to power sources.
-
Is this PDU suitable for data centers?
Yes. Its compact 1U form factor and local metering are ideal for server rooms, IT closets, and other data-center environments where space efficiency and power visibility matter.
-
Does it provide energy monitoring?
Yes. The built-in local meter displays energy usage, enabling quick monitoring of load and consumption at the rack level.
-
What mounting type is supported?
The unit is designed for standard 19-inch racks and occupies 1U of rack space, making it easy to integrate into existing rack ecosystems.