Description
Eaton Tripp Lite Series 2kW Single-Phase Local Metered PDU with ISOBAR Surge Suppression
The Eaton Tripp Lite Series 2kW Single-Phase Local Metered PDU with ISOBAR Surge Suppression is a high-performance power distribution solution engineered to protect, monitor, and optimize power delivery to critical equipment in server racks, data centers, and home lab environments. Designed for reliability and ease of use, this 1U PDU combines robust surge protection with precise, real-time load monitoring to help IT professionals and enthusiasts manage energy more efficiently. With 100-127V operation, a powerful 3840 joules surge suppression rating, and a versatile outlet configuration, it ensures that you can power both high-demand devices and sensitive electronics from a single, well-protected power source. Whether you’re provisioning a dense rack of servers, a network switch stack, or an A/V rig, this unit provides the right balance of protective capability, space efficiency, and actionable power data to keep systems running smoothly.
- Real-time local metering at a glance: The PDU features an integrated energy meter that displays live load metrics directly on the unit. You’ll see current draw, voltage, and wattage in real time, enabling quick capacity assessments during deployment, maintenance windows, or when scheduling power-intensive tasks. This immediate visibility helps prevent overloading circuits and promotes proactive power management for uptime-critical gear such as servers, switches, storage arrays, and network appliances.
- ISOBAR surge suppression with 3840 joules of protection: Engineered to guard valuable equipment from power surges, spikes, and transient disturbances, the ISOBAR protection delivers substantial joule absorption to reduce the risk of damage to power supplies and electronics. This level of surge protection is particularly valuable in environments with noisy electrical mains, long cable runs, or proximity to disruptive devices, providing peace of mind for IT operations and home labs alike.
- Versatile outlet configuration for mixed loads: The PDU provides 12 x NEMA 5-20R outlets plus 2 x NEMA 5-15R outlets, enabling you to accommodate high-current devices as well as standard 15A equipment. The combination is ideal for distributing power to a variety of rack-mounted gear, from high-draw servers and network gear to smaller peripherals. The mix of outlets helps you optimize circuits and maintain balanced loading across devices within the same rack or cabinet.
- Compact 1U rack-mount form factor with long cord: This unit comes in a slim 1U enclosure that fits neatly into a standard 19-inch rack, preserving valuable rack space while keeping outlets readily accessible. A 15-foot (4.57 m) cord provides flexible routing within your data center or equipment room, allowing you to position the PDU for optimal cable management and airflow. Front-facing outlets simplify access during maintenance without needing to rearrange components behind the cabinet.
- Flexible input options for convenient installation: The PDU supports L5-20P and 5-20P input configurations, offering compatibility with various 120V power sources and helping you tailor the setup to your facility’s existing electrical infrastructure. The combination of a locking or standard plug option, along with a long cord, makes this PDU adaptable for diverse rack deployments and reduces the need for additional extensions or adapters.
Technical Details of Eaton Tripp Lite Series 2kW Single-Phase Local Metered PDU + ISOBAR Surge Suppression
- Power rating: 2 kW total, designed for 100-127V operation (approximately 16 A maximum load)
- Outlet configuration: 12 x NEMA 5-20R outlets and 2 x NEMA 5-15R outlets to accommodate high-current and standard devices
- Input and cord: Cord length 15 feet (4.57 m); input options include L5-20P and 5-20P compatibility
- Surge protection: ISOBAR surge suppression rated at 3840 joules for robust transient protection
- Metering and display: Local energy meter provides real-time readouts of load, voltage, and watts for immediate power insight
- Rack form factor: 1U rack-mountable design suitable for standard 19-inch racks; front-access outlets for easy connection and cable management
- Operating voltage: 100-127V to support common North American IT and AV equipment
- Protection level: Comprehensive surge protection to safeguard connected devices from voltage spikes and transients
How to Install Eaton Tripp Lite Series 2kW Local Metered PDU
- Prepare the rack and workspace: Ensure the rack area is clean, ventilated, and free of obstructions. Verify that you have an appropriate 100-127V circuit with adequate amperage for the anticipated load.
- Mount the PDU in the rack: Align the unit with the rack rails and secure it in a 19-inch rack in a 1U space using the included mounting hardware. Position the PDU so front-facing outlets are easily accessible for quick connection and maintenance.
- Route the power cord: Extend the 15-foot cord to a suitable power source. Ensure the selected outlet or circuit can handle the planned load without tripping breakers. If a locking plug (L5-20P) is used, secure the connector to prevent accidental disconnection during operation.
- Connect devices to outlets: Distribte power across the 12 x 5-20R and 2 x 5-15R outlets, grouping similar devices as needed to promote balanced loading. Avoid daisy-chaining devices through multiple PDUs or overloading a single outlet bank.
- Power up and verify: Power on the PDU and observe the local meter readouts. Confirm that the surge protection indicators are active and that all connected equipment powers up correctly. Conduct a basic load check to ensure you are within the PDU’s rated capacity.
Frequently asked questions
- Q: What outlets does this PDU provide?
- A: It features 12 x NEMA 5-20R outlets and 2 x NEMA 5-15R outlets to accommodate a mix of high-current and standard devices in a single rack footprint.
- Q: What surge protection rating does it offer?
- A: The ISOBAR surge suppression provides up to 3840 joules of protection against voltage transients, helping protect connected equipment from spikes and power disturbances.
- Q: What is the cord length and input configuration?
- A: The PDU includes a 15-foot (4.57 m) cord with input options of L5-20P or 5-20P to match common North American outlets and circuits.
- Q: How many rack units does it occupy?
- A: It is a 1U, 19-inch rack-mountable unit designed to maximize space efficiency in dense equipment cabinets.
- Q: Does it provide local power metering?
- A: Yes. The built-in local meter displays real-time load, voltage, and wattage, enabling immediate visibility into power usage at the rack level.
- Q: Is it suitable for 100-127V environments?
- A: Absolutely. The PDU is designed for 100-127V operation, which is common in many data centers, network closets, and home lab setups.
- Q: Can I use it with both locking and standard plugs?
- A: The unit supports input options including L5-20P and 5-20P, providing flexibility to fit your facility’s electrical configuration and preferred plug type.
- Q: What equipment is best suited for this PDU?
- A: It is ideal for servers, network gear, switches, storage devices, A/V equipment, and other rack-mounted electronics that benefit from surge protection and at-a-glance power monitoring.