This single‑phase metered power distribution unit delivers network‑grade power while providing real‑time visibility into the total load at the rack. Built for IT environments, small data centers, and equipment rooms, it combines dependable power distribution with precise local metering to help you optimize capacity, improve uptime, and manage energy usage. With 16 C13 outlets and 4 C19 outlets, a capable input connection, and a compact 0U, 40-inch depth rack footprint, this PDU is designed to support a wide range of servers, storage devices, switches, and other critical gear in a streamlined, space‑saving package. The PDUMV20H model offers built‑in digital current metering so you can monitor power consumption in real time and take proactive steps to prevent overloads and plan for future growth.
- Real‑time local metering: The built‑in digital current meter provides instantaneous visibility into the total rack load, enabling proactive capacity planning, improved energy management, and faster troubleshooting when equipment draws more power than expected.
- Versatile outlet configuration: 16 IEC C13 outlets paired with 4 IEC C19 outlets accommodate a broad range of IT equipment, including servers, switches, storage arrays, and network devices, while helping you organize power distribution efficiently within the rack.
- Flexible input and durability: C20/L6‑20P input options with a 10‑foot (3.05 m) cord offer flexible routing and easy connection to your facility power; designed for reliable operation in demanding data center environments.
- Rack compatibility and footprint: The unit is designed for 40‑inch deep, 0U rack installations, allowing it to sit flush in standard 19‑inch racks without occupying valuable vertical space, freeing room for other components and cable management.
- Energy management for uptime and efficiency: By combining robust power distribution with precise metering, this PDU supports energy‑aware IT practices, helps reduce wasted energy, and promotes reliable uptime for critical infrastructure.
Technical Details of Eaton Tripp Lite Series 3.7kW 208/230V Single-Phase Local Metered PDU
- Power rating: 3.7 kW
- Voltage: 208/230V, single‑phase
- Outlet configuration: 16 x IEC C13, 4 x IEC C19
- Input: C20/L6‑20P
- Cord length: 10 ft (3.05 m)
- Rack format: 0U footprint, designed for a 40 in. deep rack enclosure
- Metering: Local digital current metering for real‑time load reporting
- Mounting: 19‑inch rack mount compatibility with standard hardware
- Applications: Ideal for network IT applications, small computer rooms, and other equipment rack environments requiring monitored power distribution
how to install Eaton Tripp Lite Series 3.7kW 208/230V Single-Phase Local Metered PDU
- Plan placement: Determine an optimal location within a standard 19‑inch rack that accommodates a 40‑inch depth and provides clear access to the PDU’s outlets and the metering display. Ensure there is adequate clearance for cable routing and cooling around the unit.
- Prepare mounting: Gather the required rack mounting hardware compatible with your enclosure. Align the PDU’s mounting points with the rack rails, ensuring the unit sits securely and level to prevent strain on the power cord and outlet connections.
- Mount the PDU: Secure the PDU to the rack using the appropriate screws or clamps. Tighten hardware firmly to eliminate movement while avoiding overtightening that could damage the chassis.
- Connect power: Route the 10 ft cord from the C20/L6‑20P input to a suitable mains outlet that matches the PDU’s input configuration. Ensure power is off during connection, then power on after securing all connections.
- Route and organize cables: Connect servers, switches, and other devices to the C13 and C19 outlets as needed, paying attention to outlet load distribution to prevent overloading any single circuit. Use cable management practices to maintain good airflow and accessibility to the metering display for quick status checks.
- Verify metering and operation: Power up the rack equipment and confirm that the PDU’s local metering displays a current reading consistent with the connected devices. Perform a light load test to ensure stability and observe that all devices receive proper power.
Frequently asked questions
- Q: What does “local metered” mean for this PDU? A: It means the PDU provides real‑time, on‑unit metering data at the rack level, enabling you to monitor total load and make informed decisions about power usage and capacity without relying on external meters or remote monitoring.
- Q: How many outlets are included and what types are they? A: The unit offers 16 IEC C13 outlets and 4 IEC C19 outlets, offering compatibility with a broad range of IT equipment from general servers to high‑power network devices.
- Q: What voltages and phases does it support? A: It supports 208/230V, single‑phase operation, which is common for many data center and IT environments.
- Q: What is the input configuration and cord length? A: It uses a C20/L6‑20P input with a 10‑foot (3.05 m) power cord, giving flexibility in how you route power within a rack or room.
- Q: Is this PDU rack‑mountable for standard 19‑inch racks? A: Yes, it is designed for 0U mounting in a standard 19‑inch rack with a depth of about 40 inches, maximizing rack space for equipment while still accommodating robust cabling and power management needs.