Eaton Tripp Lite Series 3.7kW 208/230V Single-Phase Local Metered PDU - 8 C13 & 2 C19 Outlets, L6-20P Input, 6 ft. Cord, 1U

Tripp Lite by EatonSKU: 6058331

Price:
Sale price$237.45

Description

Eaton Tripp Lite Series 3.7kW 208/230V Single-Phase Local Metered PDU - 8 C13 & 2 C19 Outlets, L6-20P Input, 6 ft. Cord, 1U

The Eaton Tripp Lite Series 3.7kW Local Metered PDU is a compact, rack-mount power distribution unit designed for precise, real-time visibility into your IT power consumption. Engineered for reliability in network rooms, server closets, and data centers, this single-phase PDU delivers clean, distributed power across your critical equipment while offering immediate, built-in metering to help you optimize容量 usage, reduce energy waste, and plan capacity with confidence. Built for 208/230V environments, this 1U unit straddles dense rack deployments with ease, keeping cables tidy and power management simple in busy IT ecosystems. If you need a reliable, cost-effective solution to monitor and distribute power at the rack level, this PDU is a strong fit for edge, core, and small to mid-size data environments.

  • Real-time local metering: The PDU provides built-in digital current metering that delivers live load data at the rack level, empowering quick decision-making about device placement, cooling requirements, and power budgeting. With continuous visibility into total load, administrators can detect abnormalities before they impact uptime.
  • Versatile outlet configuration: Eight C13 outlets and two C19 outlets offer robust compatibility for a wide range of devices—from servers and storage to networking gear and appliances. The balanced mix supports a variety of power needs without sacrificing space or cable management.
  • Single-phase 208/230V efficiency: Designed for common data-center and IT room power rails, this PDU operates on 208/230V single-phase power, delivering dependable performance for equipment with modest to moderate power demands while maintaining energy efficiency and reduced heat output in dense racks.
  • Front-access, space-saving 1U design: The 1U form factor fits neatly into standard server racks, leaving room for cable management and other devices. Its slim profile helps maximize rack density while keeping outlets accessible for quick maintenance and swaps.
  • Reliable input and cord length: With a L6-20P input connector and a 6 ft cord, the PDU offers flexible installation options in most rack rooms. The sturdy input arrangement supports straightforward integration with existing power distribution layouts, minimizing setup time and complexity.

Technical Details of Eaton Tripp Lite Series 3.7kW 208/230V Single-Phase Local Metered PDU

  • Power capacity: 3.7 kW total distribution capacity, suitable for small to mid-range IT deployments needing reliable, scalable power management.
  • Voltage and phase: 208/230V, single-phase operation designed for common data-center and IT room power rails.
  • Outlets: 8 x C13 outlets and 2 x C19 outlets to support a broad mix of servers, storage devices, switches, and other rack-mount equipment.
  • Input connector: L6-20P for secure, compatible connection to the facility power source.
  • Cord length: 6 ft. (approximately 1.8 meters) for flexible installation in standard rack environments.
  • Form factor: 1U rack-mountable design to maximize space efficiency in dense racks.
  • Metering: Local digital current metering provides real-time load information to help track power usage directly at the point of distribution.
  • Monitoring scope: Focused on local, immediate visibility for quick on-site power decisions in IT rooms and edge environments.
  • Application fit: Ideal for network IT applications, small computer rooms, and other equipment rack deployments where real-time load data improves reliability and efficiency.

How to install Eaton Tripp Lite Series 3.7kW Local Metered PDU

  • Prepare the rack area and confirm that your rack has 1U clearance and compatible mounting rails for a PDUs of this size and weight. Ensure the front of the rack is accessible for quick meter readouts and outlet access.
  • Power down equipment in the rack if you are upgrading an existing distribution solution. Disconnect devices safely and organize cables to prevent interference with the PDU outlets.
  • Mount the PDU securely into the rack chassis using the included mounting hardware. Align the PDU so that the outlets are accessible from the front and the built-in meter is clearly visible to operators at a glance.
  • Connect the PDU input to your power source using the L6-20P connector and a suitable power cord. Ensure the connection is tight and that the power source matches the 208/230V single-phase specification described by your data-center or room requirements.
  • Route the outlets to your devices, grouping them by device type if possible for easier management. After all devices are connected, power on the rack and monitor the built-in digital current metering readout to confirm proper distribution and load balance.
  • Verify that all equipment powers on correctly and that the PDU’s meter accurately reflects the current draw. If any discrepancies appear, review cable connections and device power states, then re-check the meter reading to ensure accuracy.

Frequently asked questions

  • Q: What power configuration does this PDU support? A: It supports 208/230V single-phase power, ideal for standard IT room and data-center rails.
  • Q: How many outlets are available and what types? A: The unit provides 8 C13 outlets and 2 C19 outlets, offering compatibility with a broad range of rack-mounted devices.
  • Q: Does this PDU offer remote management? A: This is a Local Metered PDU with built-in metering for on-site visibility. It does not include remote management or outlet-level switching features in the provided specification.
  • Q: What is the form factor and installation footprint? A: The PDU is a 1U, rack-mountable unit designed to fit standard 19-inch racks with front access for outlets and metering readouts.
  • Q: How can I use the metering data? A: The built-in digital current metering provides live load information, enabling capacity planning, thermal management decisions, and proactive maintenance to protect against overloading and downtime.