Eaton Tripp Lite Series 3.8kW 200-240V Single-Phase ATS/Monitored PDU - 8 C13 and 2 C19 Outlets, Dual C20 Inlets, 12 ft. Cords, Network Card, 1U, TAA

Tripp Lite by EatonSKU: 6353203

Price:
Sale price$881.66

Description

Eaton Tripp Lite Series 3.8kW 200-240V Single-Phase ATS/Monitored PDU

Power-protect your IT infrastructure with real-time visibility and robust reliability. The Eaton Tripp Lite Series 3.8kW 200-240V Single-Phase ATS/Monitored PDU combines high-density power delivery with an intelligent network interface, delivering automatic transfer switching, precise metering and secure remote management. Designed for 19-inch racks in small data centers, network closets and server rooms, this 1U PDU optimizes energy usage, reduces downtime and simplifies compliance for both commercial and government environments. With dual C20 inlets, a generous outlet mix, and 12-foot cords, it offers flexible installation and scalable monitoring to support growing IT needs while maintaining mission-critical uptime.

  • Real-time remote monitoring: The built-in network interface continuously reports voltage, frequency and load levels, giving operators up-to-the-second insight into power health and consumption from anywhere.
  • Automatic Transfer Switch (ATS): Seamless switchover between two independent feeds maximizes uptime and protects critical devices during power disturbances or utility outages.
  • Versatile outlet configuration: Distributes power through 8 IEC C13 outlets and 2 IEC C19 outlets, delivering flexible support for a mix of servers, storage devices, switches and other rack-mounted gear.
  • Dual C20 inlets with 12 ft cords: Enables deployment across two separate power sources with long, ready-to-route input cords for easy integration into existing power infrastructure.
  • Compact 1U, rack-mount design with network card inclusion: Fits a standard 19-inch rack, ships with a built-in network card for remote management and is TAA-compliant for government procurement programs.

Technical Details of Eaton Tripp Lite Series 3.8kW 200-240V Single-Phase ATS/Monitored PDU

  • Power rating: 3.8 kW (approx. 20 A at 200-240 V) to support high-density IT equipment within a single phase.
  • Input configuration: Dual IEC C20 inlets to accommodate two separate feeds and enable ATS functionality for redundant power paths.
  • Cord length: 12 ft input cords for flexible routing to power sources and distribution panels in a busy rack room.
  • Outlet count and types: 8 x IEC C13 outlets and 2 x IEC C19 outlets to support a broad range of devices from servers to network gear and storage appliances.
  • Rack compatibility and form factor: 1U high, 19-inch rack-mountable design that fits standard server racks for efficient data-center footprint management.
  • Network management: Built-in network interface card enables remote monitoring, management and alerting via standard management protocols (e.g., SNMP) and web interfaces.
  • Monitoring capabilities: Real-time readings of voltage, frequency and load, with data logging and alert thresholds to help optimize capacity planning and prevent overloads.
  • Power protection features: Automatic Transfer Switch (ATS) ensures seamless transition between feeds in the event of a failure, helping maintain uptime for critical devices.
  • Compliance and procurement: TAA-compliant, making it suitable for government procurement and compliant purchases in managed IT environments.
  • Build and reliability: rugged construction designed for continuous operation in professional data-center environments, with robust cabling management and clear labeling for easy installation and service.

How to install Eaton Tripp Lite Series 3.8kW 200-240V Single-Phase ATS/Monitored PDU

Install in a standard 19-inch equipment rack to maximize accessibility and airflow. Use the included mounting hardware to secure the 1U unit at the desired height, ensuring there is ample clearance for the front panel indicators and rear cable routing. Verify that your facility power feeds meet local electrical codes and are wired to two independent sources connected to the dual C20 inlets. Route the 12-foot input cords from each inlet to its respective power source, taking care to avoid kinks or tension that could stress connectors.

Connect the IEC C13 and C19 outlets to the devices in your rack, balancing loads to stay within the 20 A rating per feed and avoiding overloading any single branch. Plan cable management so that power cords do not obstruct airflow or obstruct access to equipment ports. Attach the built-in network card to your management network using a standard Ethernet connection, and power up the PDU. Access the web interface or SNMP management tool to configure alert thresholds, set up emails or paging for faults, and enable remote monitoring for voltage, frequency and current draw. Finally, test the Automatic Transfer Switch by simulating a feed loss to confirm that the PDU smoothly transitions to the alternate supply without interrupting connected devices, and verify that real-time data is accurately reported in your monitoring dashboard.

Pro tip: Label cables and use color-coded tags to simplify future maintenance. Regularly review energy usage reports to identify opportunities for consolidation, load balancing and temperature control, ensuring that the PDU continues to deliver efficient, reliable power to all connected equipment.

Frequently asked questions

  • Q: What does ATS mean and why is it important? A: ATS stands for Automatic Transfer Switch. It automatically shifts the load from one power source to a secondary, verified power source with minimal disruption, providing continuity for critical devices during power interruptions.
  • Q: How many outlets does this PDU provide and what types are they? A: It provides 8 IEC C13 outlets and 2 IEC C19 outlets, allowing you to connect a mix of servers, network gear and storage devices from a single distribution unit.
  • Q: What are the input power requirements? A: The PDU operates at 200-240V AC with dual IEC C20 inlets, designed for 20A circuits and capable of handling the load in a single-phase configuration.
  • Q: Does this model come with a network card for monitoring? A: Yes, it includes a built-in network interface card that enables remote monitoring, management and alerting via the web interface or SNMP.
  • Q: Is this PDU suitable for government procurement? A: Yes, the unit is TAA-compliant, meeting requirements for many government and public-sector purchasing programs.
  • Q: What gauge of wires are used for the inlets and cords? A: The PDU uses standard IEC power connectors and 12-foot input cords designed for reliable high-load operation in data-center environments.
  • Q: Can I monitor real-time voltage, frequency and load? A: Absolutely. The built-in network interface provides real-time monitoring of voltage, frequency and current load, helping you track capacity and avoid overloads.
  • Q: How high is the unit and can it fit in a standard 19-inch rack? A: The unit is 1U high and designed for standard 19-inch rack installations, enabling compact yet scalable deployment in most IT closets and small data rooms.