Eaton Tripp Lite Series 5.7kW 3-Phase Local Metered PDU, 120V Outlets (42 5-15/20R), 208V L21-20P input, 6 ft. (1.83 m) Cord, 0U Vertical, TAA

Tripp Lite by EatonSKU: 3344804

Price:
Sale price$627.11

Description

Upgrade your data center with a dependable 3-phase local metered PDU that delivers real-time current reporting. The Eaton Tripp Lite Series 5.7kW PDU provides precise, per-phase amp readings to help you balance loads, prevent overloads, and scale your equipment with confidence. Designed for dense server rooms, telecom closets, and high-density racks, this 0U vertical PDU fits seamlessly into tight spaces while keeping rack power organized and monitored.

  • Real-time current monitoring — built-in digital meters deliver live amperage per phase, enabling proactive load balancing and preventing circuit overloads as equipment is added.
  • 3-phase power with ample outlets — 5.7 kW capacity distributed across 42 x 5-15/20R 120V outlets, ideal for servers, switches, storage, and other critical devices.
  • 208V input, flexible installation — accepts 208V L21-20P input with a 6 ft (1.83 m) cord, providing versatile connectivity for three-phase data center power sources.
  • Space-saving 0U vertical design — mount in any standard rack without consuming rack space, keeping your cabling tidy and accessible.
  • TAA-compliant for government procurement — built to meet federal procurement requirements, making it a trusted choice for public sector deployments.

Technical Details of Eaton Tripp Lite Series 5.7kW 3-Phase Local Metered PDU

  • Power rating: 5.7 kW, 3-phase
  • Outlets: 42 x 5-15/20R, 120V per outlet
  • Input: 208V, L21-20P
  • Cord length: 6 ft (1.83 m)
  • Mounting: 0U vertical rack-mount
  • Metering: Local digital meters displaying current by phase
  • Construction: Tripp Lite/ Eaton heavy-duty PDU module
  • Compliance: TAA-compliant

how to install Eaton Tripp Lite Series 5.7kW 3-Phase Local Metered PDU

  • Select a compatible rack with sufficient height and spacing for a 0U vertical PDU installation.
  • Ensure your data center power source provides a 208V three-phase supply and that you have a 208V L21-20P receptacle ready for connection.
  • Mount the PDU in the chosen rack space using appropriate mounting hardware, keeping the digital meters accessible for easy readings.
  • Connect the 6 ft (1.83 m) cord from the PDU to the 208V input receptacle (L21-20P). Confirm secure, clean connections.
  • Distribute equipment to the 42 x 120V outlets (5-15/20R) as needed, then power on and verify that the three built-in meters display steady, balanced amperage across phases.

Frequently asked questions

  • Q: What is the power capacity of this PDU?
  • A: It supports up to 5.7 kW in a 3-phase configuration.
  • Q: How many outlets are available and what type are they?
  • A: There are 42 outlets rated 5-15/20R, providing 120V output for connected equipment.
  • Q: What input voltage and plug does it use?
  • A: It uses 208V input with an L21-20P receptacle.
  • Q: What is the mounting style?
  • A: The PDU is a 0U vertical rack-mount unit designed for space-saving deployment.
  • Q: What does “local metered” mean?
  • A: The unit includes three built-in digital meters that show current (amps) per phase in real time to help you balance loads and prevent overloads.