Description
Eaton Tripp Lite Series 5.8kW 208/240V Single-Phase ATS/Monitored PDU
The Eaton Tripp Lite Series 5.8kW 208/240V Single-Phase ATS/Monitored PDU is engineered to deliver reliable power distribution and active monitoring for network IT applications and small computer rooms. This advanced Power Distribution Unit (PDU) provides robust, scalable power management essential for servers, storage, switches, and other critical equipment. With a capacity of 5.8 kW at 208/240V, it supports dense deployments while safeguarding uptime through intelligent monitoring and automatic transfer switching. Designed for real-world data center conditions, the PDU helps IT teams optimize energy use, reduce downtime, and simplify cable management in compact rack spaces. The combination of dual input feeds, a versatile outlet configuration, and a compact 2U form factor makes this Tripp Lite PDU a dependable backbone for modern rack environments that demand efficiency, visibility, and resilience. Built to meet the needs of network closets, server rooms, and small data centers, it delivers precise power distribution with the reliability and support you expect from Eaton and Tripp Lite. This model’s Trade Agreement Act (TAA) compliance further enhances its suitability for government and contractor environments, ensuring compliance and procurement flexibility.
- High-capacity, single-phase power for IT gear: 5.8 kW of power at 208/240V to support servers, storage arrays, and networking equipment while maintaining efficient thermal and electrical margins in your rack.
- Extensive outlet configuration for flexible deployments: 16 x C13 outlets, 2 x C19 outlets, and 1 x L6-30R receptacle provide broad coverage for diverse devices in a single, organized PDU footprint.
- Redundant, dual input feeds with ATS capability: Dual L6-30P inputs enable automatic transfer switching and improved uptime by allowing separate power feeds from different circuits or panels.
- Advanced monitoring and management ready: Monitored PDU design with built-in electrical sensing and load awareness to help you track energy usage, identify overload risks, and trigger alarms before issues arise.
- Compact 2U rack-mount form factor with long reach cords: 2U height fits standard 19-inch racks, while 10 ft cords give installation flexibility across data centers, server rooms, and equipment closets; TAA compliant for government procurement.
Technical Details of Eaton Tripp Lite Series 5.8kW 208/240V Single-Phase ATS/Monitored PDU
- Power rating: 5.8 kW
- Input voltage: 208/240V
- Phase: Single-phase
- Outlet configuration: 16 x C13, 2 x C19, 1 x L6-30R
- Input connectors: Dual L6-30P
- Cord length: 10 ft
- Rack height: 2U Compliance: TAA (Trade Agreement Act) compliant
- Monitoring: Monitored PDU with ATS capabilities for remote visibility and load management
How to Install Eaton Tripp Lite Series 5.8kW 208/240V Single-Phase ATS/Monitored PDU
Installing this PDU in a standard 19-inch rack is straightforward and designed to minimize downtime while maximizing reliability. Follow these general steps to prepare and mount the unit, connect power, and enable monitoring. Always observe your organization’s electrical safety standards and local electrical codes when performing installations.
- Prepare the rack and mounting: Ensure your rack is securely installed and rated for the 2U footprint of the PDU. Gather mounting rails or brackets compatible with the 19-inch rack system and align the PDU’s mounting holes.
- Mount the PDU in the rack: Slide the unit into position and secure it with the provided screws or hardware. Confirm the PDU is level and firmly attached to prevent vibration or shifting during operation.
- Connect dual inputs: Attach each of the Dual L6-30P input cords to separate power sources or electrical circuits as required by your redundancy strategy. Ensure the circuits can handle the load and that proper circuit protection is in place.
- Route and connect outlets: Plan outlet usage to balance load across circuits. Connect servers, switches, storage devices, and other IT gear to the 16 C13 outlets, 2 C19 outlets, and the 1 L6-30R receptacle as needed, keeping power cables tidy to maintain airflow.
- Configure monitoring and alerts: If the PDU supports remote monitoring, configure any available network interfaces or management software to capture real-time load, voltage, and temperature data. Set alert thresholds appropriate for your equipment and data center environment.
- Test and validate: Power up the rack, verify each outlet is energized, and confirm that the ATS switching, if engaged, operates as expected during simulated power disturbances. Confirm that monitoring readings reflect actual voltage, current, and load on each branch outlet.
Frequently asked questions
- Q: What outlets are included on this PDU? A: The PDU provides 16 C13 outlets, 2 C19 outlets, and 1 L6-30R receptacle to accommodate a wide range of IT devices in a single unit.
- Q: What are the input options? A: It features dual L6-30P inputs for redundant or separate power feeds, improving uptime in mission-critical environments.
- Q: What voltage and phase does it support? A: It operates at 208/240V single-phase, suitable for many data center and IT equipment racks.
- Q: How tall is the PDU in a rack? A: The unit is 2U high, designed to fit standard 19-inch racks without occupying excessive space.
- Q: Is this PDU compliant with government procurement standards? A: Yes, it is TAA compliant, making it eligible for contracts and procurement under government programs.