Eaton Tripp Lite Series 7.7kW Single-Phase 200-240V Basic PDU, 4 C19 Outlets, IEC 309 32A Blue Input, 3.6 m Cord, 1U Rack-Mount

Tripp Lite by EatonSKU: 4222545

Price:
Sale price$390.18

Description

Eaton Tripp Lite Series 7.7kW Single-Phase 200-240V Basic PDU

The Eaton Tripp Lite Series 7.7kW Single-Phase 200-240V Basic PDU is a compact, dependable power distribution solution designed to meet the essential needs of data centers, server rooms, and technical workspaces. Built to deliver stable, clean power to critical equipment, this 1U rack-mount PDU combines high capacity with practical, straightforward design. With four C19 outlets, a blue IEC 309 32A input, and a long 3.6-meter cord, it offers flexible placement in standard 19-inch racks while keeping cabling organized and accessible. This is a practical choice for organizations seeking reliable distribution for servers, storage devices, switches, and other essential IT gear without unnecessary complexity. The Basic PDU focuses on delivering robust performance where it matters most, helping minimize downtime and maximize uptime for busy data centers and IT closets.

  • High-capacity power distribution: 7.7 kW of single-phase power supports multi-device deployments in a single chassis, enabling you to power dense rack workloads without overloading circuits. This level of capacity is ideal for mid-range server racks, storage arrays, and networking gear that require steady, uninterrupted supply on a compact footprint.
  • Reliable 200-240V input with IEC 309 connection: A blue IEC 309 32A input provides a secure, industry-standard connection for data center power distribution. The 200-240V range aligns with common facility electrical configurations, ensuring compatibility with existing infrastructure and minimizing the need for adapters or voltage converters.
  • Four C19 outlets for flexible IT connections: Four C19 receptacles give you ample, common mounting points for servers, switches, storage controllers, and other critical components. The arrangement supports clean cabling and scalable configurations, making it easy to group equipment by function or by rack bay.
  • Long 3.6-meter power cord for versatile placement: The extended cord length affords flexible routing within your rack ecosystem, allowing you to position the PDU for optimal airflow, cable management, and accessibility to power sources while keeping outlets reachable for routine maintenance.
  • Space-efficient 1U rack-mount form factor: The 1U height minimizes rack footprint while delivering dependable power distribution. This slim profile helps maximize usable rack space for servers and other devices, simplifying installation in crowded data centers and network rooms.

Technical Details of Eaton Tripp Lite Series 7.7kW Single-Phase 200-240V Basic PDU

  • Power rating: 7.7 kW total capacity for single-phase operation.
  • Phase: Single-Phase power distribution.
  • Input voltage: 200–240V compatibility to suit standard data center electrical infrastructure.
  • Input connector: IEC 309 32A blue input plug for secure, compliant connections.
  • Outlets: 4 C19 outlets to support common enterprise equipment.
  • Cord length: 3.6 meters for flexible installation options.
  • Rack fitting: 1U rack-mount form factor compatible with standard 19-inch racks.
  • Configuration: Basic PDU design focused on reliable, essential power distribution without advanced management features.

How to install Eaton Tripp Lite Series 7.7kW Single-Phase 200-240V Basic PDU

  • Prepare the rack: Verify you have a standard 19-inch rack with available 1U space where the PDU will be mounted. Ensure there is adequate clearance for airflow and easy access to outlets and the input connection.
  • Mount the PDU: Slide the Basic PDU into the rack rails and secure it using the appropriate screws or mounting hardware. Confirm that the PDU is level and firmly attached to prevent movement during maintenance or cable connection.
  • Route power and cabling: Plan cable paths to minimize clutter and maximize airflow. Route the 3.6-meter cord so it doesn’t obstruct front-to-rear airflow and leaves room for future expansion or reconfiguration.
  • Connect the input power: Power off the facility circuit and connect the IEC 309 32A blue input plug to a suitable 200–240V power source. Verify secure engagement and proper insulation before powering on.
  • Connect devices to outlets and test: Attach servers, storage devices, and networking equipment to the four C19 outlets. Restore power and verify that connected devices boot properly and report stable voltages. Monitor for any unusual warmth or tripping on the circuit.

Frequently asked questions

  • What is the power capacity of this PDU? The Eaton Tripp Lite Series 7.7kW Basic PDU is rated for 7.7 kW of single-phase power, providing ample headroom for mid-density rack configurations and multiple devices sharing a common power source.
  • How many outlets does it have? It features four C19 outlets, suitable for common data center servers, storage devices, and networking equipment.
  • What type of input plug does it use? The PDU uses an IEC 309 blue input plug rated at 32A, designed for secure, industry-standard connections at 200–240V.
  • What rack size will it occupy? This is a 1U rack-mount PDU, designed to fit into standard 19-inch racks while leaving space for other equipment and proper airflow.
  • Is this a feature-rich PDU with remote management? This model is described as a Basic PDU, focusing on reliable distribution without advanced management features. If you need monitoring, remote control, or circuit-level analytics, consider a higher-tier PDU with these capabilities.