Eaton Tripp Lite Series 8.6kW 3-Phase Local Metered PDU, 208/120V Outlets (36 C13, 6 C19, 6 5-15/20R), 208V L21-30P, 6 ft. (1.83 m) Cord, 0U Vertical, TAA

Tripp Lite by EatonSKU: 3328651

Price:
Sale price$902.26

Description

Eaton Tripp Lite Series 8.6kW 3-Phase Local Metered PDU

The Eaton Tripp Lite Series 8.6kW 3-Phase Local Metered PDU is engineered to deliver reliable, scalable power distribution for modern data centers and server rooms. With an 8.6 kW rating and 208/120V output, this local metered PDU provides real-time visibility into energy usage, helping IT teams optimize power consumption, prevent overloads, and maintain uptime for critical equipment. Its dense, 0U vertical design fits quickly into tight rack spaces, maximizing space in crowded data centers while maintaining easy access to power for all devices. The outlet mix—36 C13, 6 C19, and 6 5-15/20R—supports a wide range of devices from high-density servers and storage arrays to networking gear and peripherals. An input compatible with 208V systems and a 6 ft (1.83 m) power cord offer flexible installation options, whether you’re upgrading an existing rack or deploying a new one. Built to withstand demanding environments, this PDU combines durable construction with straightforward maintenance, enabling data center teams to monitor and manage power with confidence. In short, it delivers dependable power to critical infrastructure while offering clear visibility into energy usage for smarter capacity planning and cost control.

  • High-density 8.6 kW, 3-phase power distribution: Designed for data centers and server rooms, this PDU handles demanding IT loads with a reliable 8.6 kW capacity and 208/120V output to support a wide range of equipment in multi-rack environments.
  • Versatile outlet configuration for mixed IT gear: 36 x C13 outlets accommodate servers and storage devices, 6 x C19 outlets handle higher-current equipment, and 6 x 5-15/20R outlets cover common office and networking peripherals, providing flexible expansion options.
  • Flexible power input and long cord for easy installation: The 208V L21-30P input connector pairs with a 6 ft (1.83 m) cord to simplify routing in standard data center racks and ensure compatibility with existing power distribution layouts.
  • Space-efficient, 0U vertical rack mounting: The compact, 0U form factor fits into tight rack profiles while still delivering full outlet capacity, enabling high-density deployments without sacrificing airflow or access.
  • Local metering for real-time visibility and compliance-ready design (TAA): Real-time power monitoring helps with capacity planning and energy budgeting, and the TAA-compliant design makes it suitable for government and enterprise environments seeking transparent, auditable power distribution.

Technical Details of Eaton Tripp Lite Series 8.6kW 3-Phase Local Metered PDU

  • Power capacity: 8.6 kW
  • Voltage/outlets: 208/120V output with 36 x C13, 6 x C19, and 6 x 5-15/20R outlets
  • Input plug: 208V L21-30P
  • Cord length: 6 ft (1.83 m)
  • Mounting style: 0U vertical 19" rack-mount
  • Outlet configuration: Mixed outlets to support servers, storage, and networking gear
  • Metering: Local metering for real-time power monitoring
  • Compliance: TAA-compliant for use in government and enterprise environments

How to install Eaton Tripp Lite Series 8.6kW 3-Phase Local Metered PDU

  • Step 1: Plan and verify power availability: Confirm a 208V three-phase supply capable of supporting up to 8.6 kW. Ensure the L21-30P receptacle or appropriate panel configuration is available to feed the PDU.
  • Step 2: Prepare the rack space: Verify there is sufficient 19" rack space for a 0U vertical installation. Clear the area of obstructions and ensure proper airflow around the rack.
  • Step 3: Mount the PDU in the rack: Use the provided mounting hardware to secure the PDU into the correct 19" rack position, verifying a solid, vibration-free installation.
  • Step 4: Connect the power input: Route and connect the 6 ft cord to the 208V power source (L21-30P). Ensure a clean, unobstructed path for cables to prevent airflow blockage and to minimize tripping hazards.
  • Step 5: connect equipment to outlets: Distribute servers, storage devices, networking gear, and peripherals among the 36 C13, 6 C19, and 6 5-15/20R outlets. Balance the load to avoid overloading any single circuit and adhere to the PDU’s total capacity.
  • Step 6: power on and verify readings: Switch on the PDU and confirm that power is delivered to connected devices. Check the local meter or any connected management software for accuracy of voltage and current readings.
  • Step 7: configure monitoring and documentation: If the PDU provides a local display or integrates with management software, configure thresholds, alerts, and reporting. Document the wiring scheme and outlet assignments for future maintenance and audits.

Frequently asked questions

  • Q: What is the power rating of this PDU? A: The PDU is rated at 8.6 kW, designed for 3-phase data center power distribution with 208/120V outputs.
  • Q: What outlets are included? A: The unit offers 36 x C13 outlets, 6 x C19 outlets, and 6 x 5-15/20R outlets to accommodate a wide range of IT equipment, from servers to networking gear.
  • Q: What is the input plug? A: The PDU uses a 208V L21-30P input connection, compatible with standard 208V three-phase power feeds in data centers.
  • Q: Is the PDU rack-mountable? A: Yes. It features a 0U vertical form factor designed for 19" racks, enabling dense, space-efficient deployments in data centers and server rooms.
  • Q: Is the PDU compliant with industry standards? A: The product is TAA-compliant, making it suitable for use in government and enterprise environments requiring transparent procurement standards.

Customer reviews

(0)

0 Out of 5 Stars


5 Stars
0
4 Stars
0
3 Stars
0
2 Stars
0
1 Star
0


Showing - Of Reviews


You may also like

Recently viewed