Description
Unlock efficient, scalable rack space with the Eaton Tripp Lite SRCOLOKIT45UDP Colocation Kit. Specifically designed to convert a 45U deep SmartRack enclosure from a single, large compartment into a secure, dual‑compartment solution, this kit enables two tenants, teams, or workloads to share a single cabinet without compromising accessibility or organization. Perfect for data centers, colocation facilities, and enterprise IT rooms, the kit supports clean separation of services, improved security, and streamlined cable management while preserving airflow and serviceability. Built to integrate with the trusted SmartRack ecosystem, it delivers a robust, cost‑effective path to higher density, greater flexibility, and easier tenancy management in a growing IT environment.
- Dual‑compartment design—Transforms a 45U standard‑depth rack into two independent compartments, enabling two tenants or workflows to coexist in one cabinet while maintaining separation of equipment, cabling, and service access.
- Easy integration with SmartRack enclosures—Specifically engineered for 45U Deep SmartRack cabinets, the SRCOLOKIT45UDP uses standard mounting rails and hardware to deliver a clean, professional installation with minimal disruption to existing IT gear.
- Durable construction and secure partitions—Built from sturdy steel with a durable powder‑coat finish, the kit provides rigid, stable partitions that preserve security and isolation between compartments while supporting reliable long‑term operation.
- Efficient cable management and airflow—Includes dedicated channels and access points for each compartment, reducing cable clutter, improving airflow, and simplifying maintenance, serviceability, and future scalability.
- Versatile, space‑savvy solution—Ideal for data centers, colocation facilities, and enterprise IT rooms seeking to maximize rack density, simplify tenancy, and enhance security without deploying additional cabinets.
Technical Details of Eaton Tripp Lite Series SmartRack Colocation Kit for 45U Deep Rack Enclosures
- Model / SKU: SRCOLOKIT45UDP
- Intended enclosure depth: 45U deep SmartRack enclosures (standard depth)
- Configuration: Converts a single 45U rack into a dual‑compartment colocation rack
- Construction: Steel with durable powder‑coat finish for long‑lasting durability
- Partition layout: Two independent compartments designed to maintain tenancy isolation while sharing one cabinet frame
- Included hardware: Rails, brackets, mounting screws, and fasteners needed to install the dual compartments
- Design intent: Optimizes space, supports multi‑tenant deployments, and aligns with SmartRack system standards
- Security and access: Provides clear separation of components and cabling while preserving convenient access to each compartment
How to install Eaton Tripp Lite Series SmartRack Colocation Kit for 45U Deep Rack Enclosures
- Review compatibility: Confirm your enclosure is a standard‑depth 45U SmartRack cabinet and that space is available for two separate compartments without impeding doors, doors clearance, or venting.
- Unpack and inventory: Lay out all components from the SRCOLOKIT45UDP kit. Verify the presence of partitions, rails, mounting hardware, and any installation guides provided by the manufacturer.
- Plan the partition layout: Determine the exact separation line within the 45U space to designate left and right (or front and rear) compartments. Aligning this plan with cabling routes helps maintain orderly builds.
- Install the partitions: Attach the dual compartments’ vertical or horizontal dividers according to the included hardware and guidelines. Ensure partitions are plumb, secure, and compatible with existing rails and mounting locations.
- Mount equipment and route cables: Install components into each compartment, keeping power, data, and cooling paths distinct. Use the kit’s cable management channels to organize cables, label per compartment, and maintain proper airflow.
- Verify operation and accessibility: Check that doors can open and close without interference, verify that each compartment has adequate clearance for maintenance, and confirm that cooling airflow remains unobstructed in both spaces.
- Finalize labeling and documentation: Document the tenancy or workload assignments for each compartment, and ensure that service personnel can quickly identify the two separate environments within the same cabinet.
Frequently asked questions
- Q: What is the primary purpose of the SRCOLOKIT45UDP? A: It converts a single 45U deep SmartRack enclosure into a dual‑compartment colocation rack, enabling two tenants or workloads to share one cabinet with clear separation and organized cabling.
- Q: Is this kit compatible with all 45U SmartRack enclosures? A: It is designed to work with standard‑depth 45U SmartRack cabinets and should integrate with compatible mounting rails and frames in that family. Always verify mounting points and clearance with your specific model.
- Q: Do I need special tools to install the kit? A: Basic hand tools are typically sufficient, and the kit includes the necessary mounting hardware. Always follow the provided installation guidelines for proper torque and alignment.
- Q: Will the dual compartments affect airflow or cooling? A: The design preserves airflow by providing dedicated pathways and partitions that minimize cross‑over of hot air between compartments. Proper cable management further supports consistent cooling.
- Q: What components are included with the kit? A: The SRCOLOKIT45UDP includes partitions/dividers, mounting rails or brackets, screws, and other hardware necessary to configure a 45U cabinet into two independent compartments, along with installation instructions.