Furman BATT1500-EXT UPS External Battery Pack

FurmanSKU: 4453837

Price:
Sale price$703.23

Description

Furman BATT1500-EXT UPS External Battery Pack

The Furman BATT1500-EXT UPS External Battery Pack is a purpose-built, high-capacity expansion battery designed to seamlessly extend the runtime of your Furman F1500-UPS. Engineered for professional environments—from live sound stages and broadcast studios to corporate AV setups—this 2U external battery pack provides dependable, scalable power when you need it most. Its rugged all-metal enclosure protects eight 12V 9Ah batteries, configured for reliable redundancy and long-lasting performance, while its compact footprint and rack- or tower-mount versatility ensure your power solution fits neatly into existing setups. If you rely on critical equipment that cannot afford downtime, the BATT1500-EXT is engineered to help you stay energized through outages, power fluctuations, and demanding workloads.

  • Compatibility and form factor: Designed to aesthetically and functionally pair with the Furman F1500-UPS, the BATT1500-EXT is a true 2U external battery pack that can be mounted in a standard rack or positioned as a tall, space-saving tower. This compatibility ensures a cohesive, professional look while preserving the reliability and performance you expect from Furman. The combination creates a unified power solution ideal for touring rigs, broadcast environments, and fixed installations where space and organization matter.
  • High-capacity battery configuration: Inside the all-metal enclosure are eight 12V 9Ah batteries arranged as two strings of four in series. This configuration provides robust backup capacity, delivering extended runtime for connected equipment while maintaining stability and performance under load. By using two parallel strings, the system is designed for improved longevity and reliability, helping to minimize the risk of sudden power loss during critical moments.
  • Rugged build and simple integration: The BATT1500-EXT is constructed to withstand the demands of mobile and fixed installations. Its heavy-gauge construction and secure enclosure protect sensitive cells from impact and environmental factors, while the included plug-n-play DC connectors simplify installation. You can expect straightforward integration with your F1500-UPS without complicated wiring or custom adapters, enabling faster setup and easier maintenance in the field or on-site venues.
  • Versatile installation options: This external battery pack is designed to fit a variety of deployment scenarios. In rack installations, it aligns with standard 19-inch equipment racks, preserving a clean, professional rack layout. In tower configurations, it can stand independently to save floor space or be positioned as part of a vertical power infrastructure. The dual-mount capability ensures you can tailor the setup to your space, airflow requirements, and accessibility preferences.
  • Practical benefits for professionals: By expanding the runtime of the F1500-UPS, the BATT1500-EXT helps protect critical audio, video, lighting, and communications equipment during outages or momentary brownouts. This translates to fewer interruptions during productions, more stable performance during live events, and better uptime management for facilities relying on UPS-backed power. For rental houses, broadcast studios, and venue technicians, the external battery pack offers a scalable path to longer outages without sacrificing reliability or ease of use.

Technical Details of Furman BATT1500-EXT UPS External Battery Pack

  • Batteries: Eight 12V 9Ah batteries housed in a single external pack
  • Configuration: Two strings of four in series, designed to deliver a robust and dependable backup capability with parallel redundancy
  • Enclosure: All-metal, rugged construction built to endure travel, mounting, and frequent handling in demanding environments
  • Form factor: 2U external battery pack that matches the F1500-UPS form factor for a cohesive setup
  • Mounting options: Rack-mount or tower-mountable to suit your installation needs and space constraints
  • Connectors: Heavy-gauge power cord with plug-n-play DC connectors for straightforward installation
  • Compatibility: Specifically designed to extend the runtime of Furman F1500-UPS, providing a seamless, integrated power solution

How to Install Furman BATT1500-EXT UPS External Battery Pack

  • Prepare the system: Power down and unplug the Furman F1500-UPS and ensure the workspace is free of obstructions. Verify that the external battery port on the F1500-UPS is accessible and ready for connection.
  • Choose your mounting location: Decide whether you will mount the BATT1500-EXT in a standard 19-inch rack or position it as a tower. Ensure adequate ventilation and clearance for cable connections and heat dissipation.
  • Connect the DC interface: Use the included plug-n-play DC connectors to link the BATT1500-EXT to the dedicated external battery port on the F1500-UPS. Ensure connectors are firmly seated and oriented correctly to avoid improper contact.
  • Secure the unit: If rack-mounting, align the unit with the rack rails and secure it using appropriate rack screws. If tower-mounted, stabilize the unit to prevent tipping and ensure good airflow around the enclosure.
  • Power up and test: Reconnect mains power to the F1500-UPS and power it on. Allow the UPS and external battery pack to initialize. Run a controlled test to confirm the extended runtime and monitor status indicators to verify healthy operation.

Frequently Asked Questions

  • Q: Is the BATT1500-EXT compatible with the F1500-UPS? A: Yes. The BATT1500-EXT is explicitly designed to extend the runtime of Furman F1500-UPS, delivering a seamless, integrated power expansion for professional setups.
  • Q: How many batteries are inside the BATT1500-EXT? A: The pack houses eight 12V 9Ah batteries, arranged as two strings of four in series for reliable backup performance and scalable runtime.
  • Q: What mounting options does the BATT1500-EXT offer? A: It is designed for rack-mount or tower-mount deployment, allowing you to optimize space, airflow, and accessibility in your venue or studio environment.
  • Q: How do I install the BATT1500-EXT? A: Install by powering down the UPS, choosing a mounting method, connecting via plug-n-play DC connectors to the external battery port, securing the unit, and testing the system to verify operation.
  • Q: Can the runtime be quantified? A: Runtime depends on total load and discharge depth. The BATT1500-EXT is designed to extend the F1500-UPS runtime, but exact duration will vary with the equipment connected and operating conditions. For precise estimates, consult your load profile and the UPS efficiency specs.