HPE 48-Outlet PDU
The HPE 48-Outlet PDU is a high-density, 0U power distribution unit designed to maximize rack space, improve data-center uptime, and support scalable growth in demanding environments. Engineered for professional IT deployments, this IEC 60A (3PH) PDU delivers reliable power distribution across 48 outlets, with 36 IEC 60320 C13 receptacles and 12 IEC 60320 C19 receptacles. Operating at 230 V AC and up to 17.30 kW, it is built to handle the needs of modern servers, storage arrays, and networking gear while preserving efficiency and simplifying cable management in dense racks.
- Dense 48-outlet configuration (36 IEC 60320 C13 + 12 IEC 60320 C19) for flexible, scalable power delivery to servers, storage, and network devices.
- 0U, rack-mountable design to maximize rack space and enable streamlined cold-aisle and cable Management in data centers.
- IEC 60A (3PH) plug/connector with 230 V AC input supports high-density IT loads and efficient distribution for multi-node deployments.
- Maximum power rating of 17.30 kW, providing ample headroom for current and future equipment without needing additional PDUs.
- Rugged build and IEC outlet compatibility crafted to enhance uptime, simplify maintenance, and improve overall data-center efficiency.
Technical Details of HPE 48-Outlet PDU
- Outlet configuration: 36 x IEC 60320 C13, 12 x IEC 60320 C19
- Input/Plug: IEC 60A (3PH) plug/connector
- Voltage: 230 V AC
- Maximum power: 17.30 kW
- Unit size: 0U, rack-mountable
- Design purpose: High-density power distribution for data centers and enterprise IT environments
How to install HPE 48-Outlet PDU
- 1. Verify rack compatibility: Ensure your 19-inch rack supports a 0U PDU footprint and has adequate clearance for cable management.
- 2. Prepare mounting: Acquire or use standard mounting rails and hardware suitable for a 0U PDU in your rack model; attach rails securely if required.
- 3. Mount the PDU: Slide the PDU into the rack, align mounting points, and fasten securely to maintain stability under load.
- 4. Connect power: Plug the PDU’s IEC 60A 3PH connector into a suitable 230 V, three-phase power source, following your facility’s electrical guidelines and local codes.
- 5. Organize and power on: Route power cords to devices, label outlets for easy identification, apply load gradually, and verify that all connected equipment powers on correctly.
Frequently asked questions
-
What outlets are included on the HPE 48-Outlet PDU?
It provides 36 IEC 60320 C13 outlets and 12 IEC 60320 C19 outlets for versatile connections to a wide range of IT equipment.
-
What is the input voltage and phase?
The PDU is designed for 230 V AC input with a three-phase 60A connector, suitable for high-density data-center deployments.
-
What is the unit size?
It is a 0U rack-mountable PDU, optimized to maximize rack density without consuming additional vertical space.
-
Is this PDU rack-mountable?
Yes. The 0U form factor is specifically engineered for seamless integration into standard 19-inch racks.
-
What is the maximum power rating?
The PDU supports up to 17.30 kW, providing ample headroom for high-density server and networking loads.