HPE Brocade 32Gb/20 4SFP+ Fibre Channel SAN Switch Module for HPE Synergy

Are you looking to optimize your SAN fabric with a high-performance, scalable interconnect? The HPE Brocade 32Gb/20 4SFP+ Fibre Channel SAN Switch Module for HPE Synergy is designed to deliver next-generation 32Gb Fibre Channel connectivity in a compact, composable form factor. This Gen6 interconnect module integrates seamlessly into the HPE Synergy platform, enabling a single fabric that grows with your workloads. Ideal for data-intensive applications such as databases, virtualization, analytics, and backup, it helps organizations reduce latency, increase throughput, and simplify fabric management. Built to complement HPE Synergy’s software-defined architecture, the switch module supports rapid provisioning, consistent performance, and a flexible path to scale as your storage requirements evolve. With a focus on reliability and efficiency, it embodies the core principles of modern data center design: modularity, automation-ready operations, and an adaptable compute-to-storage fabric that accelerates time to insight.

  • The Gen6 Brocade Fibre Channel technology at the heart of this module delivers up to 32Gbps per port, ensuring peak bandwidth for demanding workloads and large-scale storage fabrics. With four high-density SFP+ ports, IT teams can attach multiple storage arrays, backup targets, and storage area networks with lower latency and improved IOPS into every fabric path. This level of performance is ideal for mission-critical databases, virtualized environments, and analytics workloads where every millisecond of latency matters. The design is optimized to minimize bottlenecks, so sequential and random I/O operations move faster from host to storage, enabling faster backups, faster restores, and more responsive VDI experiences. The 32Gbps per-port capability is complemented by advanced in-switch flow control and congestion management to preserve throughput even in busy fabric scenarios, making it a reliable backbone for modern data centers.
  • With 4 SFP+ ports, the module provides flexible, high-density connectivity that can scale with your storage footprint. Organizations can consolidate multiple FC fabrics into a single, coherent SAN, simplify zoning, and streamline fabric management through familiar Brocade features and management workflows. The compact interconnect footprint is designed for HPE Synergy chassis, allowing easy hot-plug insertion into the appropriate interconnect bays. This flexibility makes it simple to evolve from smaller deployments to large-scale fabrics as data growth requires more bandwidth and more storage targets without a complete rip-and-replace of the infrastructure.
  • Designed specifically for HPE Synergy, this switch module is a key element of a composable infrastructure that aligns compute, storage, and network resources under unified orchestration. By integrating directly with HPE Synergy Composer and the Synergy Image Stream, administrators gain consistent policy-based provisioning, simplified firmware management, and repeatable fabric configurations. The Gen6 interconnect brings enhanced telemetry, improved operational efficiency, and the ability to automate chassis interconnects as part of a software-defined data center strategy. This coherence across the stack reduces manual intervention, accelerates deployment, and helps maintain predictable performance for multi-tenant or mixed-workload environments.
  • Reliability and resiliency are built into the architecture through robust fabric services that protect data integrity and ensure stable operation in production. Key capabilities include fast failover between links, deterministic path selection, and solid error handling that minimizes impact on active workloads. In addition, the module supports standardized management interfaces and sensors that feed into HPE’s orchestration tools, enabling proactive monitoring, firmware enforcement, and rapid remediation. The result is a fabric that not only performs at high levels but also remains stable under variable traffic patterns, during patch cycles, and as storage partners upgrade their arrays.
  • Future-proofing and total cost of ownership are central to this module’s value proposition. By leveraging Gen6 technology, customers receive lower latencies, higher efficiency, and better energy-per-bit metrics compared with earlier generations. The modularity of HPE Synergy means this switch can be upgraded or reconfigured as business needs evolve, avoiding major forklift upgrades. Its integration within the Synergy ecosystem also reduces cables, simplifies inventory, and enables repeatable deployment patterns—important for organizations pursuing digital transformation with predictable budgets and timelines.

Technical Details of HPE Brocade 32Gb/20 4SFP+ Fibre Channel SAN Switch Module for HPE Synergy

  • Port count: 4 SFP+ Fibre Channel ports
  • Link speed: Up to 32 Gbps per port (GEN6 technology)
  • Interconnect type: Fibre Channel SAN switch module designed for HPE Synergy interconnect bays
  • Module family: Brocade 32Gb Fibre Channel SAN interconnect for HPE Synergy
  • Fabric integration: Built to operate within the HPE Synergy composable infrastructure and managed through Synergy Composer
  • Reliability features: Designed for stable operation within production SAN fabrics and compatibility with standard FC fabrics and zoning practices

How to install HPE Brocade 32Gb/20 4SFP+ Fibre Channel SAN Switch Module for HPE Synergy

  • Step 1: Power down or verify hot-plug capability of the HPE Synergy chassis interconnect bays according to your operational policies. If hot-plug is supported in your environment, ensure you follow proper safety procedures and have a current firmware baseline for the Synergy Fabric. Prepare the module by verifying its model and bay compatibility with your Synergy frame.
  • Step 2: Remove any maintenance panels or blanking plates from the designated interconnect bay. Inspect the bay for dust and debris, and confirm that the rack and cabling are organized to prevent strain on the SFP+ connectors.
  • Step 3: Align the switch module with the interconnect bay and slide it into place until the latch engages securely. Confirm a firm seating of the module and verify that the LED indicators indicate proper power and link status as applicable to your chassis design.
  • Step 4: Connect your Fibre Channel cables to the four SFP+ ports, ensuring LC fiber connectors are correctly oriented and that the fiber type matches your storage array requirements. Use appropriate cable lengths to maintain signal integrity and avoid excessive bend radii. Route cables to minimize interference and to preserve airflow within the cabinet.
  • Step 5: Power up the chassis or allow the module to come online if hot-plug is supported. Access the HPE Synergy Composer to discover the new interconnect module and apply any required firmware updates or baseline configurations. Confirm that the module is visible in the fabric inventory and that the ports are reporting link activity at expected speeds.
  • Step 6: Create or adjust FC zoning and masking policies as needed for your storage targets. Verify end-to-end connectivity by running storage I/O tests, validating saturation levels, and confirming that hosts can access their designated storage targets with expected performance.
  • Step 7: Document the configuration and establish a firmware maintenance plan. Schedule periodic checks for firmware updates, security patches, and compatibility with storage arrays and host adapters. Maintain a changelog for future reference and auditability.

Frequently asked questions

  • Q: What is the main purpose of the HPE Brocade 32Gb/20 4SFP+ Fibre Channel SAN Switch Module for HPE Synergy?

    A: It serves as a high-performance, low-latency Fibre Channel interconnect module designed to integrate with HPE Synergy. It provides four 32Gbps SFP+ ports to connect servers and storage arrays within a scalable, composable SAN fabric, enabling fast data transfer and streamlined management for modern data centers.

  • Q: How does Gen6 technology benefit my storage environment?

    A: Gen6 technology delivers higher bandwidth, improved efficiency, and lower latency per port, which translates to faster I/O, better throughput for large-scale workloads, and a more responsive storage network. It also supports advanced fabric features and telemetry that enhance visibility and control across the SAN fabric.

  • Q:Is this module hot-pluggable within an HPE Synergy frame?

    A: Yes. The HPE Synergy interconnect modules are designed for hot-plug operation within the supported chassis, allowing you to add or upgrade interconnects with minimal downtime. Always follow the vendor’s hardware maintenance procedures and verify firmware compatibility during replacement.

  • Q: What planning considerations should I account for when deploying this module?

    A: Consider your storage targets, expected workload mix, and host connectivity requirements. Plan for appropriate zoning and fabric paths, ensure firmware compatibility across all fabric components, and align with your backup, disaster recovery, and business continuity objectives. Also factor in redundancy and future growth when sizing the number of interconnects and paths.

  • Q: How do I optimize performance after installation?

    A: Start with applying the latest Gen6 firmware, verify link speeds on all ports, and configure appropriate zoning rules to minimize unnecessary traffic. Use the HPE Synergy Composer for centralized monitoring and automation, and run periodic performance tests to identify bottlenecks. Regularly review fabric topology and adjust workloads to maintain consistent latency and throughput as your environment evolves.