Description
HPE Enlogic by nVent G3 Metered 1-Phase PDU — 7.3kVA, IEC60309 332P6, 32A, 200-240V
Take control of power distribution in your IT environment with the HPE Enlogic by nVent G3 Metered PDU. This 1-phase, metered power distribution unit delivers reliable, scalable power for data centers, edge deployments, and enterprise server rooms. With a capacity of 7.3 kVA and a 32A rating at 200-240V, it provides ample headroom for high-density gear while enabling granular energy monitoring at the outlet level. Built for durability, the G3 PDU uses premium materials and robust construction to maintain performance in demanding installations, ensuring power continuity even in hot, crowded, or constrained spaces. Backed by a 5-year manufacturer warranty, this PDU combines advanced power management with long-term peace of mind, making it a trusted choice for IT teams seeking reliability and efficiency.
Design and engineering from HPE Enlogic and nVent converge in this G3 model to deliver precise load management, improved fault protection, and easy integration into standard rack ecosystems. The IEC60309 332P6 configuration aligns with industry safety standards, providing a secure, standardized connection point for enterprise electrical infrastructure. Whether you manage a data center consisting of multiple racks or a smaller, distributed IT footprint, the Enlogic G3 Metered PDU adds visibility, control, and resilience to your power distribution strategy.
- 1-phase metered design delivers real-time readings for voltage, current, and power at the outlet level, enabling accurate monitoring, chargeback, and proactive capacity planning across all connected devices.
- 7.3 kVA capacity supports dense server, storage, and networking equipment while leaving room for growth; paired with a 32A, 200-240V input, it ensures reliable operation under typical data center loads.
- IEC60309 332P6 configuration provides a rugged, industry-standard connector setup for safe and compatible integration into enterprise electrical systems and rack environments.
- Premium build and durability using high-quality materials and robust enclosure design to resist wear, heat, and dust, helping to maintain uptime in challenging deployment scenarios.
- Long-term warranty and support a 5-year manufacturer warranty plus access to enterprise-level service resources, ensuring ongoing reliability and service options as your IT needs evolve.
Technical Details of HPE Enlogic by nVent G3 Metered 1-Phase PDU
- Power phase: 1-phase
- Metered: Yes
- Power rating: 7.3 kVA
- Plug/connector: IEC60309 332P6
- Current rating: 32A
- Input voltage: 200-240V
How to install HPE Enlogic by nVent G3 Metered PDU
- Plan and power down: Before installation, perform standard lockout/tagout procedures and verify that the rack power is de-energized to ensure safe mounting.
- Mount the PDU: Securely mount the G3 Metered PDU in a compatible rack or enclosure according to your facility’s rack specifications and clearance requirements for heat dissipation.
- Connect to mains: Attach the IEC60309 332P6 input connector to a suitable 200-240V, 32A power source, ensuring proper grounding and compliance with local electrical codes.
- Outlet distribution: Connect IT devices to the PDU outlets, distributing loads evenly across outlets and zones to optimize heat and capacity. Use cable management practices to minimize airflow obstructions.
- Power-on and verify: Restore power and monitor the PDU’s on-board metering to confirm voltage, current, and power readings. Check for any alarms or fault indications and configure alerts as needed to maintain ongoing visibility.
Frequently asked questions
- What does “Metered” mean on this PDU? It means the unit provides real-time energy data (voltage, current, and power) for each outlet, enabling precise monitoring, chargeback, and capacity planning.
- Is this PDU compatible with HPE equipment? Yes. It is designed to integrate with HPE ecosystems and standard rack environments, making it suitable for data centers and enterprise IT rooms that house HPE gear.
- What is the warranty on the Enlogic G3 Metered PDU? The PDU is backed by a 5-year manufacturer warranty, offering protection and support for long-term reliability.
- What installation considerations should I know? Plan for adequate rack space, proper cable management, and compliance with local electrical codes. Ensure a suitable 200-240V, 32A power source and appropriate grounding for the IEC60309 connection.
- What are the key benefits of upgrading to a G3 Metered PDU? Enhanced power visibility, improved load balancing, safer operation through industry-standard connectors, and durable construction designed for busy data centers and edge environments.