HPE Enlogic by nVent G3 Metered 1-phase 8.3kVA/CS8265C 40A/200-240V PDU

HPESKU: 9750928

Price:
Sale price$2,582.41

Description

HPE Enlogic by nVent G3 Metered 1-phase 8.3kVA/CS8265C 40A/200-240V PDU

The HPE Enlogic by nVent G3 Metered PDU is a purpose-built power distribution solution designed to meet the demanding needs of modern data centers, server rooms, and enterprise IT environments. Built with premium materials and engineered for reliability, this 1-phase PDU delivers robust power distribution with precise energy metering, helping you optimize capacity, reduce energy waste, and maintain peak performance for critical workloads. With a 5-year manufacturer warranty backing its rugged construction, the G3 Metered PDU is a trusted foundation for consistent power delivery to racks and chassis where every watt counts. Whether you’re expanding a rack, refreshing older infrastructure, or deploying high-density compute, this PDU provides stable voltage, dependable surge protection, and real-time visibility into energy usage to drive smarter capacity planning and greener IT operations.

  • Powerful, scalable distribution for enterprise environments: The HPE Enlogic G3 Metered PDU supports 1-phase input and a high 40A rating, delivering up to 8.3kVA of usable power to your rack. This combination provides ample headroom for dense server configurations, storage arrays, and network gear while preserving clean, stable power delivery. Real-time load information helps operators balance circuits, prevent overloads, and plan future expansions with confidence, keeping critical workloads online and performing at peak efficiency.
  • Exacting energy metering for smarter data center management: This metered PDU offers precise energy measurement at the outlet level, enabling granular visibility into how individual devices consume power. By monitoring real-time usage, IT teams can identify power-hungry equipment, schedule workloads in off-peak periods, and implement energy-saving strategies without compromising performance. The result is lower operating expenses, improved thermal management, and better alignment of power capacity with IT demand across the rack.
  • Rugged, enterprise-grade construction with a long warranty: Premium materials and a robust chassis design are engineered to endure the rigors of data center environments, frequent maintenance cycles, and continuous operation. The G3 Metered PDU is built to maintain performance under load, resist wear, and withstand the temperature, dust, and vibration typical of server rooms. As a testament to this durability, the unit is backed by a 5-year manufacturer warranty, providing peace of mind for mission-critical deployments and long-term IT investments.
  • Flexible installation and seamless integration: With a rack-mountable form factor and a 200-240V input range, this PDU easily integrates into existing racks and power distribution schemes. Its compact footprint and straightforward cabling allow rapid installation, minimizing downtime during upgrades or new deployments. The Enlogic G3 ecosystem is designed to integrate with enterprise-grade management tools, giving administrators a cohesive view of power consumption across multiple PDUs and racks for centralized control and reporting.
  • Comprehensive safety, reliability, and support: The PDU adheres to industry safety standards and incorporates protective features to prevent overload, short circuits, and electrical faults from impacting connected equipment. In addition to its built-in safeguards, customers benefit from dedicated technical support, readily available replacement parts, and the confidence of a well-established warranty program that covers the product for years of dependable service in demanding data center conditions.

Technical Details of HPE Enlogic by nVent G3 Metered 1-phase 8.3kVA/CS8265C 40A/200-240V PDU

  • Model: CS8265C — HPE Enlogic by nVent G3 Metered PDU
  • Phase: 1-phase input for simplified distribution in standard data center racks
  • Voltage: 200-240V AC to support common IT equipment and data center circuits
  • Current rating: 40A, designed to handle high-density loads without overloading circuits
  • Power rating: Up to 8.3kVA for demanding server, storage, and networking gear
  • Metering: Real-time energy measurement at the outlet level to monitor consumption and enable efficiency improvements
  • Construction: Enterprise-grade, premium materials with a durable chassis intended for continuous operation
  • Warranty: 5-year manufacturer warranty for long-term reliability and coverage
  • Compatibility: Designed to integrate with HPE Enlogic G3 ecosystem and enterprise power management tools
  • Mounting: Rack-mountable design to fit standard IT racks and streamline deployment

How to install HPE Enlogic by nVent G3 Metered 1-phase 8.3kVA/CS8265C 40A/200-240V PDU

Installing the HPE Enlogic G3 Metered PDU is a straightforward process designed to minimize downtime and maximize reliability. Before you begin, verify that the rack, circuit, and environment meet the PDU’s electrical and safety requirements. Ensure that the power source matches the 200-240V input specification and that the circuit you connect to is rated for 40A. Turn off power to the rack or cabinet area as you perform any connections, and follow standard electrical safety practices to prevent accidental shock or short circuits.

Step 1: Prepare the rack and space. Confirm that the rack offers adequate mounting positions for the PDU and that there is enough clearance for cable management and ventilation. Position the PDU in a location that minimizes cable tension and maximizes accessibility for monitoring and maintenance. Keep vented areas clear to maintain optimal airflow around powered devices.

Step 2: Mount the PDU. Use the appropriate hardware provided to secure the PDU to the rack rails. Ensure that the unit is level and firmly attached to prevent vibration or movement during operation. If the installation requires multiple PDUs, plan channel routing and vertical cable management to reduce clutter and simplify future serviceability.

Step 3: Connect input power. Attach the PDU’s input power cord to a dedicated 200-240V, 40A circuit that matches the PDU rating. Use appropriate connectors and verify secure, strain-relieved connections. Once connected, perform a careful check to ensure there are no loose wires or signs of insulation damage before powering on.

Step 4: Connect IT devices. Route power cords from servers, storage devices, and networking gear to the PDU outlets. Use trunking or cable ties to organize cables and maintain clean airflow within the rack. If the PDU supports outlet-level metering, verify that each device is connected to the intended outlet and that the metering readouts reflect expected load values during initial power-on testing.

Step 5: Configure metering and monitoring. Access the PDU’s management interface or utilize your Enlogic-compatible monitoring tools to enable real-time energy tracking. Set up alerts for overcurrent or abnormal power draw and establish baseline usage patterns for capacity planning. Document settings for asset management and future audits, ensuring that IT staff can reproduce successful configurations across multiple racks.

Step 6: Verify operation and safety checks. Power up the rack and confirm that all connected devices boot normally. Check for any unusual heat signatures or abnormal sounds from power components and verify that cooling and airflow remain unobstructed. Confirm that metered data reports correlate with on-site observations, and adjust load distribution as needed to maintain performance while staying within electrical limits.

Frequently asked questions

Q: What is the power rating of this PDU?
A: The HPE Enlogic G3 Metered PDU is rated for 8.3kVA with a 40A current rating, operating on a 200-240V supply. This combination offers substantial headroom for high-density IT deployments while providing precise energy measurement to support efficiency initiatives.

Q: Is this PDU metered?
A: Yes. The CS8265C model includes outlet-level metering, giving you real-time visibility into power consumption for individual connected devices. This enables better capacity planning, energy optimization, and cost management across the rack.

Q: What warranty comes with the PDU?
A: The HPE Enlogic G3 Metered PDU is backed by a 5-year manufacturer warranty, reflecting its focus on reliability, long service life, and support for mission-critical IT environments.

Q: How does this PDU integrate with HPE Enlogic management?
A: The G3 series is designed to integrate with Enlogic management ecosystems, providing centralized visibility, reporting, and control across multiple PDUs in the data center. This supports consolidated power monitoring, alerting, and asset tracking in enterprise environments.

Q: What installation considerations should I keep in mind?
A: Plan for adequate clearance for airflow, cable management, and access to outlets. Ensure the input circuit is sized for 40A and compatible with 200-240V. Use proper rack mounting hardware and follow safety procedures when connecting power. After installation, validate metering accuracy against actual device consumption and set up alerts for unusual power usage.