HPE ProLiant DL3X5 Gen11 Max Performance 2U Heat Sink Kit

HPESKU: 6825640

Price:
Sale price$263.94

Description

HPE ProLiant DL3X5 Gen11 Max Performance 2U Heat Sink Kit

Introducing the HPE ProLiant DL3X5 Gen11 Max Performance 2U Heat Sink Kit — the essential cooling upgrade engineered for high-demand Gen11 DL3X5 systems. This heat sink kit is designed to maximize processor performance, sustain reliability under continuous workloads, and support climate-controlled operation in dense data centers. Built for 2U rack deployments, it delivers superior thermal management, reduces thermal throttling, and extends component life by maintaining consistent, optimal temperatures even under peak processing loads. If you’re optimizing for performance per watt in a Gen11 environment, this heat sink kit is a strategic investment that helps you extract the full potential of your HPE infrastructure while preserving uptime and stability across mission-critical workloads.

  • Optimized Thermal Design for Gen11 — The DL3X5 Gen11 Max Performance 2U heat sink kit features a high-efficiency heat sink geometry and metal alloy construction designed to maximize heat dissipation. Its carefully engineered fins and contact surface area promote rapid heat transfer from the processor to the cooling airflow, enabling sustained performance during intensive workloads such as large-scale virtualization, data analytics, and AI-based workloads. The result is reduced thermal throttling and a steadier clock rate, even during multi-core bursts.
  • 2U Form Factor with Superior Airflow Compatibility — Precisely engineered for 2U rack environments, this kit aligns with the DL3X5 Gen11 chassis and takes advantage of the existing airflow paths. The design minimizes rear-obstructing protrusions and helps maintain consistent intake-to-exhaust flow, working in harmony with compatible fans and ducting to prevent hotspot formation. This compatibility translates into easier integration for data centers deploying dense server racks while preserving cooling efficiency across the enclosure.
  • Durable Construction for Long-Term Reliability — Built from robust heat-conductive materials chosen for long-term reliability, the kit is designed to withstand the rigors of data center operation. The solid mounting interface provides repeatable, secure contact with the CPU, ensuring stable thermal performance over time. The kit’s construction supports maintenance cycles and field service scenarios, helping minimize downtime during replacements or upgrades.
  • Easy Integration with Gen11 ProLiant Ecosystem — This heat sink kit is engineered to integrate smoothly with HPE ProLiant DL3X5 Gen11 platforms, preserving compatibility with the broader Gen11 ecosystem. It supports consistent thermal behavior across the platform, enabling predictable performance and straightforward firmware and BIOS tuning. For administrators, this translates to simpler capacity planning and fewer surprises in dynamic workload environments.
  • Energy-Efficient Cooling for Cost Confidence — By optimizing heat transfer and reducing CPU temperature fluctuations, the kit helps lower overall cooling energy consumption per server. This not only contributes to better data center efficiency but also supports quieter operation by enabling the cooling system to run more efficiently at lower fan speeds under lighter loads. It’s a practical upgrade for organizations pursuing green IT and lower total cost of ownership on Gen11 workloads.

Technical Details of HPE ProLiant DL3X5 Gen11 Max Performance 2U Heat Sink Kit

  • Product Type: Heat sink kit for HPE ProLiant DL3X5 Gen11 Max Performance 2U servers
  • Form Factor: 2U rack-mount form factor compatible with DL3X5 Gen11 configurations
  • Material: High-grade heat-conductive alloy designed for durable performance and reliable thermal transfer
  • Compatibility: Specifically designed for HPE ProLiant DL3X5 Gen11 Max Performance 2U systems and related Gen11 server families
  • Warranty: Manufacturer warranty; terms vary by region and distributor—please refer to the retailer’s warranty policy

How to Install HPE ProLiant DL3X5 Gen11 Max Performance 2U Heat Sink Kit

Step 1 — Prepare the system: Power down the server completely, disconnect all cables, and place the unit on an antistatic mat. Open the chassis access panel following your data center’s standard maintenance procedures. Gather the necessary tools and verify you have the correct replacement heat sink kit for the DL3X5 Gen11 platform. Review any HPE installation notes or guides to ensure compatibility with your specific module revision and BIOS version.

Step 2 — Remove the existing cooling assembly: If a prior heat sink is installed, carefully detach it according to the service manual. Use anti-static precautions to avoid damaging components and take note of mounting orientations and thermal interface material placement. Clean the processor surface if required, ensuring no debris or old TIM remains that could impede thermal contact. Proper cleanup ensures maximum heat transfer with the new kit.

Step 3 — Prepare and mount the new heat sink: Align the DL3X5 Gen11 Max Performance 2U heat sink kit with the processor socket and mounting holes. Ensure that the thermal interface material (TIM) is correctly placed and evenly distributed as per the kit’s instructions or the HPE guidelines. Engage the mounting hardware in a crosswise pattern to apply even pressure across the processor surface, then tighten to the recommended torque specification if provided. Avoid overtightening to prevent warping or damage.

Step 4 — Reassemble and verify: Refit the chassis cover, reconnect all cables, and restore power. Boot the server and enter the BIOS/UEFI to verify thermal management settings and ensure the new heat sink is recognized. Monitor processor temperatures under idle and peak-load conditions using preferred monitoring tools. Confirm that fans respond appropriately and that there are no abnormal alarms related to overheating.

Step 5 — Confirm ongoing performance: Run representative workloads to validate cooling performance under real-world conditions. Check for thermal consistency across cores and ensure that no throttling occurs under sustained load. Document temperature trends and compare against baseline measurements to quantify the improvement introduced by the heat sink upgrade. Schedule periodic inspections to ensure mounting integrity and continued effective heat transfer over time.

Frequently asked questions

Q: What exactly is the HPE ProLiant DL3X5 Gen11 Max Performance 2U Heat Sink Kit?
A: It is a specialized cooling component designed to upgrade or replace the heat-dissipating assembly on HPE ProLiant DL3X5 Gen11 Max Performance 2U servers. The kit optimizes thermal transfer from the processor to the cooling system, enabling higher sustained performance and reducing the risk of thermal throttling during intensive workloads.

Q: Which systems is this heat sink kit compatible with?
A: The kit is engineered for HPE ProLiant DL3X5 Gen11 Max Performance 2U servers and related Gen11 DL3X5 configurations. For exact compatibility with your model and revision, refer to your server’s maintenance guide or contact your vendor to confirm the correct part number and fit before purchase.

Q: Do I need to apply additional thermal interface material (TIM) when installing the kit?
A: Many heat sink kits include or pre-apply TIM per manufacturer guidelines to ensure proper contact and heat transfer. Follow the specific instructions included with the kit or the HPE installation guide. If TIM is not pre-applied, apply a thin, even layer as directed to achieve optimal thermal performance without creating gaps or excessive thickness.

Q: What kind of performance improvement can I expect?
A: Expect lower CPU temperatures, reduced thermal throttling, and more stable performance under sustained workloads. The exact improvement depends on your workload, ambient data center conditions, and overall system configuration. In typical high-density environments, administrators report improved headroom for peak-processing tasks and more predictable thermal behavior across the DL3X5 Gen11 platform.

Q: How should I maintain the heat sink kit after installation?
A: Periodic inspection is recommended. Check mounting screws for tightness, verify there is no dust buildup obstructing airflow, and confirm that the airflow path remains clear. If you notice rising temperatures or unusual fan noise, recheck mounting integrity and cleanliness of the heatsink surfaces. Adhere to your data center’s maintenance schedule to sustain cooling efficiency.


Customer reviews

(0)

0 Out of 5 Stars


5 Stars
0
4 Stars
0
3 Stars
0
2 Stars
0
1 Star
0


Showing - Of Reviews


You may also like

Recently viewed