HPE R/T3000 3000VA Tower/Rack Mountable UPS
Experience enterprise-grade reliability with the HPE R/T3000 3000VA Tower/Rack Mountable UPS, a line-interactive uninterruptible power supply engineered for mixed environments where uptime matters. Whether you deploy in a compact server room, a busy office, or a laboratory, this UPS is designed to protect critical devices from power outages, voltage sags, and data-loss incidents. Its flexible form factor lets you position it as a traditional tower or rack-mount unit, delivering robust protection for servers, network switches, storage arrays, and other essential equipment. With advanced battery management, intelligent diagnostics, and user-friendly monitoring, the HPE R/T3000 helps you extend runtime, optimize battery health, and maintain business continuity even under challenging electrical conditions.
Key to its appeal is a balance of power and practicality. The 3000VA rating translates into reliable support for mid-range server workloads, high-performance networking gear, and critical peripherals without breaking the bank or consuming excessive space. A smart design emphasizes energy efficiency and quiet operation, ensuring minimal disruption in environments where noise and heat can impact performance. The R/T3000’s rack-tower versatility makes it an ideal fit for evolving IT setups, allowing you to scale your protection as your infrastructure grows. Coupled with diagnostic awareness and clear status indicators, this UPS gives you peace of mind that critical systems stay online when the grid falters.
From a security and management perspective, the HPE R/T3000 is built to integrate smoothly with common data-center workflows. USB and serial management interfaces provide straightforward connections to monitor the unit, trigger safe shutdowns, and log events for post-incident analysis. The unit’s design emphasizes quick setup and simple maintenance, enabling IT staff to deploy, test, and verify protection with minimal downtime. In short, the HPE R/T3000 3000VA UPS is a versatile, future-ready power protection solution that aligns with modern hybrid data center models, edge deployments, and sophisticated business continuity strategies.
- Flexible deployment for diverse spaces: The HPE R/T3000 is designed to operate as both a tower and a rack-mountable unit, giving you the flexibility to adapt to existing furniture, cabinets, or 19" rack enclosures. This adaptability is ideal for organizations consolidating hardware or reconfiguring data rooms, allowing you to maximize protection without overhauling your environment. The ability to switch between configurations simplifies migrations, minimizes downtime during changes, and preserves your investment as needs evolve.
- Line-Interactive topology with AVR for voltage stability: This UPS employs a line-interactive architecture that continuously buffers and stabilizes incoming power. Automatic Voltage Regulation (AVR) corrects common voltage fluctuations without draining the battery, extending runtime for critical devices and reducing wear on the battery over time. For offices and data centers facing irregular mains quality, AVR helps prevent unnecessary battery discharge while maintaining a clean, protected output signal to connected equipment.
- Smart battery management and diagnostics: The R/T3000 emphasizes intelligent battery health and proactive maintenance. Built-in battery monitoring and self-test capabilities help you detect aging cells before they fail, schedule routine maintenance, and avoid unexpected outages. Diagnostic data can be leveraged to optimize replacement schedules, ensuring you’re not over-provisioning or under-protecting essential assets. This focus on battery health translates into longer overall uptime and lower lifecycle costs.
- Critical-load protection with clear visibility: Protects servers, networking gear, storage devices, and other mission-critical payloads from sudden outages and disruptive power events. The UPS provides reliable clean power with surge protection and robust overload handling, while intuitive status indicators and a user-friendly interface keep IT staff informed about runtime, battery condition, and input/output behavior. By delivering stable power, the R/T3000 helps maintain data integrity, application availability, and user productivity during disturbances.
- Comprehensive management and connectivity: USB and serial communication options enable seamless integration with common management software and monitoring tools. In addition to on-device indicators, you can monitor runtime, battery health, and event history through software, enabling automated shutdowns and alerts when conditions warrant action. This connectivity supports proactive IT operations, facilitating consistent maintenance, audit trails, and reliable remote management in distributed environments.
Technical Details of HPE R/T3000 3000VA Tower/Rack Mountable UPS
- Power rating: 3000 VA
- Topology: Line-Interactive
- Form factor: Tower and rack-mountable design
- Management interfaces: USB and Serial ports for monitoring and control
- Runtime characteristics: Runtime varies with load; supports battery health monitoring and self-tests
how to install HPE R/T3000 3000VA Tower/Rack Mountable UPS
- Plan placement: Choose a well-ventilated area with adequate clearance for cooling and easy access to outlets and management ports. If mounting in a rack, ensure alignment with rails and secure mounting hardware is available.
- Mount configuration: Use the supplied hardware to install the unit as a tower or into a standard 19" rack. Ensure the UPS is level and securely fastened to prevent movement during maintenance or in the event of a floor disturbance.
- Power and load connections: Connect the UPS input to a dedicated circuit with appropriate protective devices. Plug protected critical devices (servers, switches, storage) into the UPS output outlets. Avoid overloading outlets beyond the unit’s rated capacity.
- Management setup: Connect a USB or Serial cable to a management computer or server. Install the recommended management software, then configure alarms, automatic shutdown policies, and event logging to align with your IT procedures.
- Initial check and calibration: Power on the UPS, run an initial self-test, and verify that connected devices respond to a simulated power event. Adjust AVR settings and notification preferences as needed to match your voltage environment and organizational policies.
Frequently asked questions
- What does the HPE R/T3000 protect? It protects critical equipment such as servers, network switches, storage gear, and other devices that require stable, reliable power to maintain uptime and prevent data loss during outages or irregular mains conditions.
- Can the UPS be used in both tower and rack configurations? Yes. The R/T3000 is explicitly designed to be tower- or rack-mountable, enabling flexible deployment in varied environments without additional adapters or hardware beyond the included mounting kit.
- Does it support intelligent battery management? Yes. The unit includes battery health monitoring, self-tests, and diagnostic features to help you plan maintenance and extend battery life, reducing the risk of unexpected battery failure during outages.
- What management options are available? The UPS offers USB and Serial interfaces for direct monitoring and control. Depending on the model, you may also access management software for remote monitoring, event logging, and automated shutdown procedures to protect data integrity.
- How can runtime be extended? Runtime can be extended by reducing load, using equipment with lower power demands, or adding external battery packs if supported by your configuration. The AVR feature also helps optimize battery use by maintaining stable output without unnecessary discharge during minor voltage fluctuations.
- Is installation complicated? Not particularly. The unit ships with mounting hardware for tower or rack use, and the setup involves securing the chassis, connecting the load to the UPS output, wiring to the mains, and configuring management software or alerts. Most IT staff can complete setup with reference to the user guide.
- What should I expect in terms of maintenance? Regular battery health checks, firmware or software updates if available, and routine self-tests are recommended. The built-in diagnostics help schedule servicing before battery degradation affects performance.
Customer reviews