HPE R5000 5kVA Rack-mountable UPS

HPESKU: 5524483

Price:
Sale price$6,179.83

Description

HPE R5000 5kVA Rack-mountable UPS

Protect your critical IT workload with the HPE R5000 5kVA Rack-mountable UPS, engineered to deliver enterprise-grade power protection when uptime is non-negotiable. This online double-conversion UPS provides seamless power delivery to servers, storage, and networking gear, eliminating transfer time to battery power and preserving data integrity during outages or disturbances. Built for data centers, edge deployments, and demanding IT closets, the HPE R5000 combines robust electrical protection with intelligent battery management to maximize runtime, extend battery life, and minimize operational risk. The rack-mountable design fits cleanly into standard 19-inch racks, simplifying installation and asset management while offering scalable protection that grows with your environment. From short-duration outages to sustained power events, this UPS is engineered to maintain clean, reliable power to keep services online, users productive, and applications responsive.

  • High availability power protection: Online double-conversion technology isolates connected equipment from irregular power conditions, providing a pure sine-wave output and uninterrupted operation even during utility outages or voltage sags. This eliminates transfer time to battery and safeguards critical workloads from sudden shutdowns.
  • Rack-mountable 5kVA design: Engineered for data centers, server rooms, and edge deployments, the R5000 fits into standard 19-inch racks for compact, organized power protection without sacrificing capacity or performance.
  • Enhanced Battery Management: Intelligent battery management optimizes charge cycles, extends battery life, and enhances runtime predictability, helping you plan maintenance windows and reduce total cost of ownership.
  • Remote monitoring and management: Built-in communication options and compatibility with HP software enable proactive monitoring, alerting, and remote configuration to simplify maintenance and improve service levels across IT operations.
  • Energy efficiency and power quality protection: Efficient operation reduces energy consumption while delivering precise voltage regulation, surge protection, and protection against transients that can harm sensitive electronics.

Technical Details of HPE R5000 5kVA Rack-mountable UPS

  • Power rating: 5 kVA / up to approximately 4 kW output capability depending on load and power factor
  • Form factor: Rack-mountable 19-inch chassis designed for standard data centers and IT closets
  • Topology: Online double-conversion (double-conversion, true online UPS) for continuous clean power
  • Input range: Auto-sensing AC input with wide voltage window to accommodate variable utility power
  • Output: Regulated, maintenance-free sine-wave output suitable for servers, storage, and networking gear
  • Battery system: Modular, maintainable battery components with status monitoring and health reporting
  • Management and communications: Local management and remote monitoring options via USB, serial, and optional network interface
  • Protection features: Automatic voltage regulation (AVR), overload and short-circuit protection, and environmental protection monitoring
  • Operating environment: Suited for data centers and enterprise IT spaces with reliable thermal and vibration tolerance

How to install HPE R5000 5kVA Rack-mountable UPS

Follow these general steps to install the HPE R5000 UPS in a standard IT rack and bring it online safely. Always consult the official installation manual for model-specific instructions, wiring diagrams, and safety precautions before beginning any work.

  • Plan placement: Verify rack space, ventilation, and clearance around the UPS and adjacent equipment. Ensure the rack is level and that mounting rails are properly rated for the UPS weight and dimensions.
  • Mount the UPS: Attach the provided rails to the rack and secure the HPE R5000 into place. Confirm that the unit is firmly mounted and level to prevent vibration and thermal issues during operation.
  • Connect input power: Route a dedicated AC input power cord from a suitable circuit to the UPS input. Use appropriately rated circuit breakers and follow local electrical codes. Ensure power is off during connection and verify grounding requirements are met.
  • Connect IT loads: Plug servers, storage devices, switches, and other critical equipment into the UPS output receptacles or distribution system as specified by the manufacturer. Do not exceed the rated output to avoid nuisance tripping or harmonic-related issues.
  • Configure and monitor: Attach a USB, serial, or network management interface as needed. Install the HP monitoring software or compatible companion tools, configure notification thresholds, and set shutdown policies to align with your SLA needs.
  • Perform a check and test: Power on the units, verify voltage and battery health indicators, and conduct a controlled transfer test to battery to confirm seamless protection during outages. Validate communication with management software and run any built-in diagnostics.

Frequently asked questions

  • What kind of workloads is the HPE R5000 designed to protect? It is engineered to safeguard critical IT workloads, including servers, virtualization platforms, storage arrays, and network devices, by providing uninterrupted power during outages and voltage disturbances for high-availability environments.
  • Can the R5000 support external battery modules? Yes, the system is designed with scalable, modular battery options to extend runtime as needed, enabling longer protection in environments with extended power outages or demanding recovery times.
  • How can I monitor the UPS status remotely? The R5000 offers multiple management interfaces (USB, serial, and optional network interface) and is compatible with HP monitoring software, allowing real-time status alerts, event logging, and remote administration from a central console.
  • What is the expected efficiency and waveform quality? As an online double-conversion UPS, it produces a clean sine-wave output with high-efficiency operation at typical load levels, helping reduce energy costs and improve reliability for sensitive equipment.
  • What maintenance is required? Periodic battery health checks, firmware and software updates for management interfaces, and routine visual inspections are recommended. When needed, replaceable battery modules can be serviced by qualified personnel to minimize downtime.