Description
HPE SN8600B 8-slot Power Pack+ Director Switch
The HPE SN8600B 8-slot Power Pack+ Director Switch represents a pinnacle in scalable storage networking, built to meet the demands of today’s data centers. Engineered for high-performance Fibre Channel fabrics, this director-class switch delivers massive bandwidth, deterministic latency, and enterprise-grade reliability that private clouds and virtualized environments rely on. With up to 64Gbps FC performance per port and as much as 31Tbps of chassis bandwidth, the SN8600B is designed to handle I/O-intensive workloads, large-scale virtualization, and accelerating mission-critical databases while ensuring consistent, predictable access to consolidated storage resources. Designed for ease of integration into existing SAN fabrics, this switch provides the robust fabric governance, non-disruptive upgrades, and scalable growth required by modern IT infrastructures. Whether you’re expanding a SAN with new servers, consolidating multiple storage arrays, or building a private cloud storage backbone, the SN8600B is engineered to deliver the performance, reliability, and manageability you need in a highly virtualized data center.
- Unmatched bandwidth for demanding workloads: Experience up to 64Gbps Fibre Channel performance per port, enabling rapid data movement for high-velocity databases, in-memory workloads, virtual machines, and bandwidth-hungry storage arrays. This level of throughput reduces bottlenecks, accelerates backups and restores, and supports large-scale data migration projects without compromising performance.
- Massive chassis capacity for growing fabrics: The SN8600B delivers up to 31Tbps of aggregate chassis bandwidth, providing headroom for expanding server counts, more storage shelves, and increasingly complex fabric topologies. Plan for future growth with confidence, knowing your SAN can scale without sacrificing reliability or predictability.
- 8-slot Power Pack+ Director configuration: Designed for scalable SAN architectures, the 8-slot form factor enables flexible port provisioning and non-disruptive growth. As your private cloud expands or your virtualization environment scales, you can add capacity and functionality while maintaining service levels and fabric stability.
- Optimized for private cloud, virtualization, and flash workloads: Ideal for highly virtualized environments and flash-based storage, the SN8600B delivers consistent, low-latency performance. It supports fast I/O patterns, improves storage array efficiency, and helps maximize the value of flash technologies in enterprise deployments.
- Reliability, availability, and simplified management: Built for mission-critical operations, the director switch emphasizes high availability features, workload isolation, and streamlined management across large SAN fabrics. With centralized configuration, zoning, and fabric health monitoring, administrators can maintain robust storage networks with reduced complexity.
Technical Details of HPE SN8600B 8-slot Power Pack+ Director Switch
- Product family: Director switch chassis designed for Fibre Channel SAN fabrics
- Port speed: Up to 64Gbps Fibre Channel per port
- Chassis bandwidth: Up to 31Tbps aggregate bandwidth
- Slot configuration: 8-slot Power Pack+ director capable chassis
- Workload focus: Optimized for private cloud storage, virtualization-heavy environments, and flash-based storage workloads
- Reliability and availability: Enterprise-class design with built-in redundancy and fabric management to minimize downtime
- Management and compatibility: Integrates with HPE SAN Director tooling and ecosystem for centralized fabric control and monitoring
How to install HPE SN8600B 8-slot Power Pack+ Director Switch
Installing the SN8600B is a multi-step process designed to be performed by qualified storage/network professionals. Proper installation ensures optimal performance, reliability, and serviceability across your SAN fabric. Below is a generalized guide to get you started, with best practices to help you achieve a smooth deployment while preserving fabric integrity and data accessibility.
- Plan and document your fabric topology: Before physical deployment, map your fabric design, including switch interconnections, zoning strategy, and storage arrays. Identify any redundant paths and determine how the 8-slot director will fit into your existing or planned topology to minimize downtime during integration.
- Prepare the environment: Ensure the installation site has adequate cooling, stable power with redundancy (dual power supplies where appropriate), and proper cable management. Verify rack space, airflow clearance, and grounding to prevent EMI or thermal issues that could impact performance.
- Rack mounting and power: Secure the SN8600B in a compatible rack, connect redundant power sources, and verify that all fans and indicators are functioning. Confirm that the power environment meets the switch’s requirements and that the environment remains within recommended operating temperatures during operation.
- Physically connect Fibre Channel fabrics: Attach Fibre Channel cables to designated ports according to your topology plan. Use high-quality copper or optical links rated for 64Gbps, ensuring correct LC/connector types and verified cable integrity to prevent link errors and retransmits.
- Initial fabric configuration: Access the switch management interface to configure essential fabric parameters, including fabric login, switch priority (if applicable), and basic zoning. Establish loopback tests or fabric tests to validate port states and inter-switch connectivity.
- Firmware and feature enablement: Install the latest stable firmware from HPE or the approved source, and enable necessary features such as advanced zoning, quality-of-service where applicable, and redundancy settings for non-disruptive upgrades.
- Fabric health validation: Run diagnostic checks to verify port status, latency, and bandwidth. Confirm that all paths are operational, end-to-end connectivity is stable, and storage arrays and hosts can access LUNs as intended.
- Security and governance: Apply access controls, role-based permissions, and logging configurations to monitor fabric activity. Enforce best practices for zoned access and ensure auditability for storage operations.
- Documentation and backups: Save configurations, zoning maps, and firmware versions to a secure repository. Maintain an up-to-date recovery plan and ensure that you can reproduce the fabric state if needed after upgrades or maintenance.
Frequently asked questions
- What is the HPE SN8600B 8-slot Power Pack+ Director Switch designed for? It is a director-class Fibre Channel SAN switch intended to build large, scalable SAN fabrics for data centers, enabling fast, reliable access to consolidated storage resources across multiple servers and storage arrays.
- What performance can I expect? The SN8600B delivers up to 64Gbps FC performance per port and up to 31Tbps of chassis bandwidth, providing ample headroom for busy I/O profiles, large-scale virtualization, and private cloud storage workloads.
- Is this switch suitable for private cloud environments? Yes. It is optimized to support private cloud storage workloads and highly virtualized environments, delivering low latency and consistent throughput across diverse workloads.
- How many slots does the director switch have? It is configured as an 8-slot Power Pack+ Director, offering scalable capacity and flexible port provisioning to meet evolving demands.
- Does it support flash-based storage workloads? Yes, the SN8600B is designed to handle flash-based storage workloads efficiently, helping to maximize the performance benefits of modern flash arrays while maintaining reliability and endurance.
- What management capabilities are available? The switch integrates with HPE SAN Director management tooling, enabling centralized fabric configuration, monitoring, zoning, and maintenance activities across large SAN fabrics.
Customer reviews
Showing - Of Reviews