Description
HPE SN8700C 8-slot 16/32/64Gb Fibre Channel Director Switch
Experience enterprise-grade SAN consolidation with the HPE SN8700C Director Switch. This eight-slot director brings scalable Fibre Channel performance to data centers, enabling you to consolidate data assets into fewer SANs, reduce hardware footprint, and lower CAPEX and OPEX while delivering resilient, high-availability storage networks. Engineered for demanding workloads and mission-critical applications, the SN8700C provides a robust foundation for modern storage fabrics, supporting comprehensive zoning, policy-based management, and streamlined administration that translates into faster deployment, easier operations, and improved data protection across your enterprise.
- The SN8700C enables profound SAN consolidation, letting you merge multiple storage fabrics into a single, highly manageable SAN. By centralizing chassis, controllers, and paths, you reduce the number of devices you must purchase, license, and maintain, which lowers capital expenditures and ongoing operating costs. A unified fabric simplifies capacity planning, provisioning, and DR readiness, while enabling IT teams to apply consistent storage policies across all hosts and workloads. The result is a leaner, more predictable storage environment with fewer points of failure and a clearer path to scale as your data grows. This consolidation also minimizes cabling complexity and power usage, contributing to a smaller physical footprint in the data center.
- Performance and scalability are at the core of the SN8700C. Supporting Fibre Channel speeds of 16, 32, and 64 Gb/s, this director switch delivers high-bandwidth data movement with low latency, ensuring fast access to mission-critical databases, VDI deployments, and large-scale backups. The eight-slot architecture provides ample headroom for growth—hardened for mission-critical workloads, with the ability to add more directors or scale within the fabric without disruptive downtime. With a total fabric capacity up to 24 Tbps, you can accommodate expanding storage systems, new tiered storage configurations, and evolving virtualization strategies while preserving consistent performance and predictable latency. This makes it ideal for hyper-converged, traditional SAN, and future-ready data-center architectures that demand scalable throughput and resilient data transport.
- Reliability and availability are foundational in the SN8700C design. Enterprise-grade redundancy is built in, with options for hot-swappable power supplies and cooling components to minimize downtime during maintenance or component failures. The director switch supports non-disruptive upgrades and firmware updates, helping you keep the fabric secure and up-to-date without impacting running workloads. Advanced fabric services provide fault isolation and rapid failover, ensuring steady data access even during partial fabric disruptions. For organizations with stringent service-level agreements, the SN8700C delivers consistent reliability, extended MTBF characteristics, and robust disaster recovery readiness through deterministic, policy-driven operations across the SAN.
- Management and security capabilities are engineered to simplify administration and tighten control over storage access. The SN8700C offers a centralized management plane for provisioning, zoning, and path management across the SAN, reducing manual tasks and configuration drift. Policy-based automation enables repeatable, auditable storage setups, while zoning and aliasing features help you enforce access controls and optimize data pathways. The director integrates smoothly with existing enterprise tooling and monitoring ecosystems, enabling consistent alerting, performance tracking, and capacity planning. With these capabilities, IT teams can accelerate deployment times, reduce human error, and maintain strong data governance across all hosts and storage arrays connected to the fabric.
- Future-proof integration and ecosystem fit are core strengths of the SN8700C. Designed to work alongside HPE storage, servers, and networking components, this director switch fits neatly into established data-center architectures and supports ongoing modernization efforts. Its compatibility with standard SAN practices ensures that organizations can leverage their existing investments while adopting newer, faster storage technologies. The SN8700C also complements virtualization, backup, and DR strategies by providing a scalable, high-availability backbone for growing data workloads. By choosing a true enterprise-grade Fibre Channel director, you gain a flexible platform that can adapt to evolving storage requirements without requiring a forklift upgrade.
Technical Details of HPE SN8700C
- Form Factor: 8-slot Fibre Channel Director switch designed for data-center deployment and high-density cabling environments.
- Fibre Channel Speeds: Supports 16, 32, and 64 Gb/s Fibre Channel to match a broad range of storage arrays and host adapters.
- Maximum Fabric Capacity: Up to 24 Tbps switching capacity, enabling large-scale SAN fabrics with reduced bottlenecks.
- Redundancy: Options for redundant power supplies and cooling to maximize uptime and support non-disruptive maintenance.
- Management Features: Centralized SAN management with zoning, aliasing, and policy-based automation to simplify provisioning and ongoing administration.
how to install HPE SN8700C
Installing the SN8700C is a strategic step toward a more resilient storage network. Before you begin, plan your fabric topology, zoning strategy, and management approach to minimize rework once the director is online. Ensure your data center has adequate rack space, appropriate rack rails, and sufficient power and cooling capacity to accommodate the eight-slot chassis and any redundant components you plan to deploy. Review your existing SAN assets to determine port assignments and compatibility with current storage arrays and HBAs, and prepare any required documentation for future upgrades or audits. Although specific steps may vary by environment, the following deployment outline reflects typical best practices for this director switch in enterprise data centers.
- Step 1: Prepare the data center and verify environmental readiness. Confirm rack space, ground isolation, power delivery, and cooling capacity. Check compatibility with existing SAN equipment, cabling standards, and rack-mount rails before starting the installation.
- Step 2: Install the SN8700C in the rack and secure it with the appropriate rails. Connect any redundant power supplies and verify that all fans and cooling paths are unobstructed. Ensure proper grounding and cable management to maintain airflow and simplify maintenance.
- Step 3: Establish physical connectivity by attaching Fibre Channel cables from host HBAs and storage arrays to the SN8700C ports according to your zoning plan. Label ports clearly and maintain a consistent cabling scheme to reduce troubleshooting time in the future.
- Step 4: Power on the switch and access the management interface. Configure initial network parameters, administrative credentials, and basic fabric settings such as domain identity, zoning policy, and alias conventions. Validate that the device reaches a healthy state and appears in your management console.
- Step 5: Implement fabric-wide policies, create zones, and define paths. Validate connectivity across representative host/storage pairs, test failover scenarios, and monitor performance and health metrics. Schedule non-disruptive maintenance windows for any firmware updates or policy changes and perform a final validation with production workloads before full-scale migration.
Frequently asked questions
- Q: What is the SN8700C best suited for? A: The SN8700C is designed for enterprise data centers seeking scalable, reliable Fibre Channel switching to consolidate SANs, centralize management, and support demanding storage workloads with high availability.
- Q: How does SN8700C help reduce TCO? A: By consolidating multiple SANs into a single fabric, standardizing management, and reducing hardware sprawl, the SN8700C lowers both capital expenditures and ongoing operational costs while delivering efficient resource utilization.
- Q: What FC speeds does SN8700C support? A: It supports 16, 32, and 64 Gb/s Fibre Channel speeds to align with a broad range of storage arrays and host adapters, enabling flexible and future-ready deployments.
- Q: Does SN8700C support non-disruptive upgrades? A: Yes. The director offers high-availability fabric services and non-disruptive upgrade capabilities to minimize downtime during maintenance and firmware updates.
- Q: Is SN8700C compatible with existing HPE SAN environments? A: The SN8700C is designed to integrate with HPE storage, servers, and SAN ecosystems, supporting standard SAN management practices and ensuring smooth interoperability with current infrastructure.
Customer reviews
Showing - Of Reviews