Description
Lantronix SLC 8000 16-Port RS-232 RJ45 I/O Module
The Lantronix SLC 8000 16-Port RS-232 RJ45 I/O Module is a purpose-built expansion accessory that unlocks new levels of flexibility and control for data centers, enterprise networks, and remote sites. Built to integrate seamlessly with the Lantronix SLC 8000 console server family, this 16-port I/O module makes it dramatically easier to adapt your serial infrastructure as your organization evolves. By enabling quick reconfiguration of input/output assignments without disconnecting attached equipment or replacing the entire console server, it dramatically reduces maintenance windows, minimizes risk, and sustains critical workflows. Whether you’re provisioning new network gear, migrating devices to new racks, or scaling your serial management capability to accommodate growing infrastructure, this module is designed to simplify administration, improve uptime, and streamline operations across diverse environments—from dense data centers to remote industrial sites. With rugged reliability, hot-swappable capability, and a compact form factor, the SLC 8000 16-Port RS-232 RJ45 I/O Module delivers a modular, future-ready solution for centralized serial management and remote access that IT teams can count on day after day.
- Flexible expansion for your SLC 8000 — Add 16 RS-232 serial ports to your console server setup, enabling scalable management of large fleets of serial devices. The module supports rapid reconfiguration of port mappings, empowering administrators to adapt to changing device deployments without downtime or disruptive rewiring.
- 16-port RS-232 with convenient RJ-45 interfaces — Each port is accessible through practical RJ-45 connectors, offering a straightforward cabling solution that matches standard data center practices. This design simplifies patching, inventory, and maintenance while preserving reliable, low-latency serial communication.
- Minimize downtime with hot-swappable design — Reconfigure or replace I/O capabilities on the fly without powering down the entire system. The hot-swappable construction of the SLC 8000 I/O module reduces service interruptions and preserves critical workflows during upgrades or port migrations.
- Optimized for centralized remote management — The module enables centralized control of serial devices from the SLC 8000 console, enabling consistent access policies, streamlined device onboarding, and simplified monitoring across distributed sites. This results in faster incident resolution and improved operational efficiency.
- Rugged, enterprise-grade reliability — Built to operate in demanding IT environments, the 16-port RS-232 I/O module supports durable performance in data centers, server rooms, telecom closets, and field sites. Its modular design aligns with best practices for scalable, maintainable infrastructure and long-term TCO reduction.
Technical Details of Lantronix SLC 8000 16-Port RS-232 RJ45 I/O Module
- Ports: 16 RS-232 serial ports
- Connectors: RJ-45 style serial interfaces for each port
- Compatibility: Designed for use with the Lantronix SLC 8000 Console Server family
- Form factor: I/O module that slots into the SLC 8000 chassis to extend serial capacity
- Power: Powered through the SLC 8000 backplane; does not require a separate external power source
- Management: Integrates with the SLC 8000 management interface for port assignment, access control, and monitoring
- Environment: Suited for data centers, enterprise networks, and remote sites requiring reliable serial management
How to install Lantronix SLC 8000 16-Port RS-232 RJ45 I/O Module
- Power down or place the SLC 8000 into maintenance mode to prevent disruption during installation. Ensure you follow your organization’s change management procedures.
- Unpack the 16-Port RS-232 RJ45 I/O Module and verify that you have all required components for installation, including any documented hardware guides from Lantronix.
- Remove the corresponding I/O slot cover or insert the new module into the appropriate expansion slot in the SLC 8000 chassis. Align connectors carefully and slide the module into place until it seats firmly in the backplane.
- Secure the module and reattach any protective covers. Reconnect any internal cables or interconnects if your deployment requires them, following the product’s wiring guidelines.
- Power up the SLC 8000 system or resume normal operation. Access the management interface to verify that the new module is recognized and that all ports are visible in the port map.
- Configure port mappings, access policies, and device profiles as needed. Assign each of the 16 RJ-45 ports to the appropriate serial devices, define baud rates, parity, flow control, and any ACLs or role-based access controls required for your environment.
- Test each port by connecting a representative device (such as a console, terminal, or serial-attached equipment) and confirm reliable bidirectional communication. Validate remote access, command execution, and monitoring alerts to ensure end-to-end operability.
- Document the new I/O configuration and update your network topology diagrams and asset inventory. Schedule periodic reviews to ensure the port assignments stay aligned with deployments and maintenance plans.
Frequently asked questions
- What is the main benefit of the Lantronix SLC 8000 16-Port RS-232 RJ45 I/O Module? It expands the SLC 8000 console server’s serial I/O capacity by adding 16 RS-232 ports via RJ-45 connectors, enabling scalable, remote management of a larger fleet of serial devices without replacing the entire console server.
- Can I hot-swap this module without shutting down the system? Yes. The design supports hot-swapping, which minimizes downtime and allows you to reconfigure or replace I/O capabilities while maintaining ongoing operations on other ports and devices.
- Is this module compatible with all SLC 8000 configurations? It is intended for use with the Lantronix SLC 8000 Console Server family. Always verify compatibility with your specific SLC 8000 model and firmware version before installation to ensure proper operation.
- How do I configure the 16 ports after installation? Use the SLC 8000 management interface to map each RJ-45 port to its target serial device, set port parameters (baud, data bits, parity, stop bits, flow control), and define access policies or automation rules as needed.
- What environments is the 16-Port RS-232 I/O Module best suited for? It is ideal for data centers, enterprise networks, remote sites, telecom closets, and industrial facilities where centralized serial management and remote access are critical for maintaining hardware, network gear, and embedded devices.
Customer reviews