Description
Lenovo DPI Enterprise PDU
The Lenovo DPI Enterprise PDU is engineered for modern data centers and demanding enterprise server rooms where uptime, efficiency, and scalable power management are non-negotiable. This enterprise-grade power distribution unit combines rugged hardware with advanced monitoring and control capabilities to deliver precise energy distribution, real-time visibility, and secure remote management. With Lenovo’s reputation for reliability and precision, the DPI Enterprise PDU helps IT and facilities teams reduce risk, optimize cooling strategies, and streamline rack-level power orchestration across dense deployments. Whether you’re outfitting a hyperscale rack, supporting a batch of blade enclosures, or provisioning a network hub, this PDU is designed to adapt to evolving workloads while preserving energy efficiency and operational continuity.
- Intelligent power distribution with real-time monitoring and remote control. The DPI Enterprise PDU provides per-outlet or bank-level metering, live power usage data, and remote on/off capabilities. With a secure web UI, SNMP compatibility, and alarm notifications, operators gain instant insight into load distribution and potential bottlenecks. This enables proactive capacity planning, rapid fault isolation, and smarter maintenance windows, which translate into higher uptime and more predictable service levels for critical applications.
- Scalable, modular design for high-density racks. Built to support expanding data centers, the DPI Enterprise PDU offers flexible configurations that accommodate varying outlet counts, input options, and mounting styles. Its modular approach makes it easy to upgrade rear-accessories, outlet modules, or sensor suites without replacing the entire unit. This scalability is essential for growing environments where space, airflow, and cable management are tightly controlled, helping you maximize rack density without sacrificing reliability.
- Energy efficiency and cost savings through metering, forecasting, and scheduling. With comprehensive energy metering and utilization dashboards, you can track exact power draw by device or group, identify idle assets, and implement outlet-level scheduling to minimize wasted energy. The DPI Enterprise PDU supports peak-shift and setpoint alerts, enabling operations teams to tune cooling and workload placement. Over time, these insights drive meaningful reductions in electricity consumption, reduce PUE, and lower operating expenses across the data center.
- Security, reliability, and compliant remote management. Enterprise-grade security features protect access to critical power infrastructure. Role-based permissions, secure authentication, encrypted communication, and tamper-evident logging help safeguard the PDU against unauthorized changes. Reliable operation is further supported by robust fault tolerance, redundant data paths where offered, and automatic firmware orchestration to keep devices up to date with the latest protections and performance enhancements.
- Seamless integration with Lenovo ecosystem and data-center management tools. The DPI Enterprise PDU is designed to play well with Lenovo ThinkSystem servers, XClarity, and data-center management ecosystems. It provides standard management interfaces (including SNMP and HTTP/S) for easy integration with existing monitoring platforms. This interoperability ensures centralized visibility, consolidated alerting, and coordinated power and asset management across your entire Lenovo infrastructure, simplifying daily administration and long-term capacity planning.
Technical Details of Lenovo DPI Enterprise PDU
- Power configuration: Available in multiple configurations to support different rack and load requirements; models vary in outlet density, input options, and mounting styles.
- Power rating: Offered in a range of amperage capacities suitable for standard and high-density deployments; exact ratings depend on the model and regional electrical standards.
- Monitoring and metering: Built-in power meters with voltage, current, and power factor data; optional environmental sensors for temperature and humidity in the rack environment.
- Networking and management: Ethernet/LAN connectivity with secure web interface; SNMP support for integration with existing monitoring systems; remote power control and alerting capabilities.
- Safety and compliance: Designed to meet common safety standards and energy-efficiency programs; compatible with data-center best practices for reliability and regulatory compliance.
How to install Lenovo DPI Enterprise PDU
- Plan and verify model selection: Confirm the DPI Enterprise PDU model that matches your rack footprint, outlet needs, and input voltage requirements before attempting installation.
- Mount in the rack: Use the provided mounting brackets to secure the PDU in a standard 19-inch rack, ensuring adequate clearance for cable routing and airflow around the unit.
- Connect power and networking: Attach the PDU to the appropriate branch circuit using compliant power cords and circuit protection. Connect the management interface (Ethernet) to your data-center network, and configure any serial or console access if available.
- Initial configuration: Access the PDU's secure web UI to set administrator credentials, define user roles, configure outlet groups, and enable energy metering features. Preserve default security settings and apply recommended firmware updates if required.
- Create monitoring and safety rules: Establish alert thresholds for temperature, humidity, and current, set up notification channels, and configure outlet control policies. Validate remote power on/off functionality for select outlets under controlled conditions.
- Test and validate operation: Power up devices incrementally, monitor live metrics, verify accurate metering, and confirm that automated alarms trigger as expected. Ensure proper airflow and cable management to prevent hot spots.
Frequently asked questions
- What is the Lenovo DPI Enterprise PDU? It is an enterprise-grade power distribution unit that provides controlled power delivery, per-outlet monitoring, and remote management to support data centers, server rooms, and other infrastructure-rich environments.
- What benefits does it offer for data centers? The DPI Enterprise PDU delivers increased uptime through real-time power visibility, improved cooling efficiency via smarter load distribution, and cost savings from energy metering and intelligent scheduling. Its secure management features simplify operations and reduce manual intervention.
- Can it be managed remotely? Yes. It supports standard management protocols such as HTTP/S and SNMP, allowing integration with existing monitoring platforms and enabling remote control of outlets, alarms, and meters from a centralized dashboard.
- Is it compatible with Lenovo ThinkSystem and other Lenovo management tools? The DPI Enterprise PDU is designed to integrate with Lenovo ecosystems and commonly used data-center management software, helping to unify server, storage, and power infrastructure under a single management pane.
- What kind of sensors are included? Depending on the model, it can include voltage, current meters, and environmental sensors like temperature and humidity to provide a complete picture of rack health and load distribution.
- How do I size and configure outlets? Outlets are configurable by bank or group, enabling you to tailor power distribution to the devices in your rack, simplify power sequencing, and optimize energy use. Always follow local electrical codes and Lenovo guidelines when selecting outlet configurations.