Liebert Basic PDU - Horizontal, 120/208V, (8) NEMA 5-20R, (2) NEMA L6-30R

LiebertSKU: 6818982

Price:
Sale price$1,176.72

Description

Liebert Basic PDU - Horizontal, 120/208V, (8) NEMA 5-20R, (2) NEMA L6-30R

The Liebert Basic PDU is a purpose-built power distribution solution designed to streamline rack-level power management in data centers, server rooms, and edge deployments. Engineered for reliability and ease of use, this horizontal PDU provides structured, efficient distribution of facility UPS or generator power to a variety of IT assets. Built to integrate smoothly with Vertiv’s GXT5 Lithium-Ion UPS systems, it simplifies the transition from a single UPS source to a scalable, organized power network across multiple devices. Whether you’re outfitting a brand-new rack or upgrading an existing installation, the Liebert Basic PDU helps you maximize uptime, reduce cable clutter, and maintain a clean, maintainable power layout for critical workloads.

Simple, dependable power distribution for critical equipment. The Liebert Basic PDU is designed around reliability and straightforward operation. With a horizontal rack-mount footprint, it fits neatly into standard 19-inch racks, making it a natural choice for space-conscious data centers and IT closets. The configuration is purpose-built to handle mixed loads—from servers and storage to networking gear and power-hungry peripherals—without introducing unnecessary complexity. This PDU focuses on delivering consistent power to IT equipment while keeping installation simple for technicians and facilities staff alike.

  • Seamless UPS integration: Specifically designed to work with the GXT5 Lithium-Ion UPS family, the Liebert Basic PDU ensures efficient distribution of UPS or generator power directly to rack equipment. This synergy simplifies setup, reduces wiring errors, and creates a unified power architecture that supports fast deployment and predictable performance in day-to-day operations. Whether you’re deploying a new rack or expanding an existing one, the Basic PDU provides a reliable bridge between your primary power source and your IT load.
  • Versatile outlet configuration for 120/208V environments: The PDU features a practical mix of outlets to support a wide range of devices. It provides eight NEMA 5-20R receptacles for general 20A circuits and two NEMA L6-30R connectors for dedicated, high-demand feeds. This arrangement allows you to tailor power delivery to equipment with different plug types and amperage requirements, while maintaining a clean, organized outlet layout that minimizes tangles and maximizes airflow around devices.
  • Horizontal, 19-inch rack-mount design: Engineered for standard IT environments, the Liebert Basic PDU’s horizontal form factor fits cleanly inside a 19-inch rack, enabling efficient use of vertical space and simplifying cable routing. The compact, sturdy enclosure is designed for long-term durability in busy data centers, server rooms, and edge facilities, where space optimization and cable management are critical for quick maintenance and inspections.
  • Durable construction and compliance: Built to withstand the rigors of daily rack use, the Basic PDU employs a robust metal enclosure and quality components to ensure dependable power distribution. It carries typical safety and compliance marks suitable for enterprise deployments, such as UL listings and RoHS compliance, reinforcing a commitment to safety, reliability, and environmental responsibility in professional IT environments.
  • Starter-friendly, with a straightforward feature set: The Basic PDU focuses on delivering reliable, uncomplicated power distribution without the overhead of built-in remote monitoring or network management. This makes installation quick and predictable, reduces configuration complexity, and provides a clear upgrade path for teams that later want to add monitoring capabilities through extenders or compatible Liebert management options when needed.

Technical Details of Liebert Basic PDU

  • Model: Liebert Basic PDU – Horizontal
  • Input/Voltage: 120/208V
  • Frequency: 60 Hz
  • Outlets: 8 x NEMA 5-20R, 2 x NEMA L6-30R
  • Mounting: Horizontal 19-inch rack-mount design
  • Construction: Durable metal enclosure; suitable for data center environments
  • Safety and Compliance: UL-listed and RoHS compliant
  • Monitoring/Management: Basic distribution without built-in network management; suitable for extensible configurations with Liebert extenders if monitoring is later required

how to install Liebert Basic PDU

Installing the Liebert Basic PDU is a straightforward process designed for data-center-grade reliability and quick deployment. Begin by planning the rack layout to ensure balanced load distribution and optimal cable management. Identify the most accessible location within the rack for servicing and connect the PDU to the appropriate power source following local electrical codes and facility policies.

1) Mount the PDU horizontally into the rack rails. Align the chassis with the 19-inch mounting plane, then secure it using the provided hardware. Ensure there is adequate clearance for ventilation and for connecting both input and output cables. A clean, unobstructed pathway reduces heat buildup and makes future maintenance simpler.

2) Connect the input power according to the installation guidelines for your facility. Use the correct power connector and cord set for 120/208V operation and ensure the input connection is rated for the expected load. It’s essential to verify that the upstream circuit breakers and feeders are sized properly for the anticipated total amperage across all connected devices.

3) Route and label the outgoing power cords to the IT equipment in a logical, organized manner. Group devices by function or by load type, and use cable management accessories to reduce clutter, improve airflow, and simplify identification during maintenance. Ensure that high-load devices do not exceed the PDU’s total rated capacity and that critical workloads have dedicated outlets where possible for stable performance.

4) Power on the system and perform a quick verification. Confirm that each NEMA 5-20R outlet is functioning and provides stable voltage under load. If you are planning to run high-demand devices on the NEMA L6-30R connectors, verify the integrity of those feeds and confirm that any required redundancies or safety measures are in place. Conduct a basic load check to ensure the total connected load remains within the PDU’s design limits, preventing nuisance tripping or overheating.

5) Label and document the configuration for future maintenance. Record outlet assignments, circuit protections, and corresponding devices. Documentation helps technicians quickly locate the correct outlets during upgrades, replacements, or service windows and supports safe, efficient operations in busy data centers.

By following these steps, you’ll achieve a clean, scalable power distribution setup that complements your Liebert GXT5 UPS integration and supports reliable RACK-level power delivery. The Basic PDU’s straightforward design minimizes setup friction while delivering robust capability for essential IT workloads, giving facilities teams a dependable foundation for day-to-day operations and future growth.

Frequently asked questions

  • Q: What is the Liebert Basic PDU used for?
    A: It’s a horizontal rack-mount power distribution unit designed to deliver reliable, straightforward power from a facility UPS or generator to multiple rack-mounted devices. It’s ideal for data centers, server rooms, and edge deployments where a simple, durable power distribution solution is preferred.
  • Q: How many outlets does it provide and what types are there?
    A: The unit features eight NEMA 5-20R outlets for standard 20A devices and two NEMA L6-30R connectors for higher-amperage, dedicated feeds. This mix supports a variety of IT equipment while allowing for flexible circuit design and load balancing.
  • Q: Does the Liebert Basic PDU include network monitoring?
    A: By design, the Basic PDU focuses on core power distribution without built-in network management. If monitoring is required, you can add Liebert extenders or compatible management options to enable remote monitoring, reporting, and alerts as your infrastructure evolves.
  • Q: Is this PDU compatible with the Liebert GXT5 UPS?
    A: Yes. The Liebert Basic PDU is intended to integrate with Liebert GXT5 Lithium-Ion UPS systems, enabling efficient transfer of power from the UPS to rack devices and providing a cohesive power distribution architecture within the rack.
  • Q: What environments is the Liebert Basic PDU suitable for?
    A: It’s designed for data centers, server rooms, and edge deployments where reliable 120/208V power distribution is needed, in a horizontal, space-saving rack-mount form factor. Its robust construction and compliance features make it appropriate for enterprise-grade applications demanding dependable power delivery.