Liebert DCE Rack System

LiebertSKU: 12515710

Price:
Sale price$7,555.24

Description

Liebert DCE Rack System

The Liebert DCE Rack System is a purpose-built data center enclosure designed to meet today’s fast-changing IT environments. Built for flexibility, quick deployment, and reliable performance, this rack system supports scalable growth from edge deployments to enterprise-scale facilities. With a focus on modularity, efficient cooling, and streamlined installation, the DCE Rack System helps data centers reduce time-to-value while delivering consistent uptime and predictable total cost of ownership. It integrates seamlessly with Liebert cooling, power, and monitoring solutions, enabling operators to consolidate space, improve cable management, and optimize airflow without compromising on security or serviceability. Whether you’re expanding capacity, upgrading infrastructure, or standardizing deployments across multiple sites, the Liebert DCE Rack System provides a robust foundation for efficient, resilient, and future-ready data center operations.

  • The Liebert DCE Rack System is designed for maximum flexibility and modularity, allowing rapid reconfiguration to accommodate changing rack densities, equipment mixes, and cooling/power requirements. The architecture supports scalable growth, so you can start with a core configuration and evolve as your data center expands, without costly retrofits or downtime. This flexibility is essential for businesses facing dynamic workloads, higher VM densities, and evolving security and compliance demands. With a smart blend of adaptable rails, accessory slots, and configurable front/back access, the DCE Rack System stays ahead of your IT roadmap and simplifies capacity planning.
  • Pre-configured rack selections and customizable configurations deliver precise outcomes for installation speed and delivery timelines. Operators can choose from curated packages that prioritize common data center use cases, or opt for fully tailored racks that align with site constraints, power distribution strategies, and cooling strategies. The result is faster procurement, reduced engineering effort on-site, and a predictable path from delivery to productive use. The system’s design emphasizes standardization while preserving the ability to tailor internal layouts, cable pathways, and component placement to project-specific needs.
  • Integrated airflow optimization, cable management, and compatibility with Liebert cooling and power solutions drive energy efficiency and uptime. The DCE Rack System supports front-to-back airflow, strategically positioned cable raceways, and blanking panels to minimize hot spots. This thoughtful airflow management reduces cooling loads, lowers energy consumption, and helps maintain equipment within its guaranteed temperature range. With rugged, durable enclosures and secure access, technicians can manage cables, perform upgrades, and route power and data cables neatly without interrupting critical workloads.
  • Ease of installation and ongoing serviceability define the user experience. The DCE Rack System features tool-less assembly options, standardized mounting rails, and clearly labeled components to simplify initial setup and field maintenance. Leveling feet, ergonomic door access, and accessible rear zones make service tasks efficient, while robust hardware ensures long-term reliability in demanding data center environments. The system is designed to minimize downtime during upgrades, migrations, or routine maintenance, helping data centers stay online and productive.
  • Built for security, durability, and operational certainty, the Liebert DCE Rack System emphasizes robust enclosure integrity, locking doors, and tamper-resistant panels where required. The enclosure materials are selected for strength, EMI shielding, and resistance to vibration and wear in busy data center floors. This durability, combined with monitoring-readiness and compatibility with remote management tools, enables IT teams to oversee environmental conditions, access control, and component health from centralized dashboards, ensuring proactive maintenance and rapid response to issues.

Technical Details of Liebert DCE Rack System

  • Technical details are pulled from the specifications section of the product on ec.synnex.com using the product UPC or SKU as reference. For complete, exact figures such as external dimensions, internal usable space, maximum rack load, weight, airflow ratings, and compatible accessories, consult the official listing with your UPC/SKU reference.

How to Install Liebert DCE Rack System

  • Preparation: Before unboxing, verify that the installation space meets the required floor load capacity and clearance around the rack for maintenance, cable routing, and cooling airflow. Confirm ambient conditions (temperature, humidity, and particulate control) align with data center standards to protect sensitive equipment and prolong enclosure life. Inspect all components against the packing list to ensure nothing is missing or damaged in transit.
  • Unpack and inspect: Carefully unpack the Liebert DCE Rack System and lay out components in a clean, organized workspace. Check for any dents or bent parts and set aside damaged items for return or replacement. Lay out rack rails, mounting hardware, and accessories in a logical order to expedite assembly and prevent misplacement later in the process.
  • Assemble base and rails: Install leveling feet or casters as appropriate for the site, then attach front and rear mounting rails per the manufacturer’s guidelines. Ensure rails are plumb and aligned to maintain proper door operation and door clearances. Use a level to confirm the enclosure sits evenly on the floor to prevent skewed mounting that could affect equipment alignment or airflow.
  • Mount the enclosure: Position the rack system into place and secure it to the floor or existing rack infrastructure following local codes and safety procedures. Confirm door swings and clearance with existing equipment and ensure unobstructed access to front and rear zones for technicians and airflow. Attach any pre-configured front and rear panels, ensuring proper fit and locking mechanisms are functional.
  • Install power and cooling interfaces: Route power distribution and cooling connections according to your data center’s design. Install any integrated PDU options, ensure appropriate circuit protection, and verify that hot-swappable components align with the rack’s serviceability plan. Maintain clean cable pathways, use cable management arms or channels, and place blanking panels to preserve airflow integrity.
  • Cable management and equipment mounting: Begin populating the rack with servers, storage, and networking gear, using the predefined rack scheme if available. Use cage nuts and rails to secure equipment, staggering heavy devices to optimize weight distribution. Systematically route power and data cables, leaving slack for maintenance while avoiding tangling and interference with cooling airflow.
  • System checks and commissioning: After physical installation, perform a thorough inspection of all connections, rails, doors, and seals. Power up the system gradually, verify that sensors report correctly, and confirm that cooling fans respond as expected. Validate airflow with intake and exhaust temperatures, verify PDU communication, and run a basic functional test of connected equipment to ensure proper mounting and integration with existing data center management tools.
  • Documentation and handoff: Compile the final installation documentation, including serial numbers, component placements, and test results. Provide operators with access credentials or monitoring configuration if applicable. Train facility staff on routine maintenance, airflow best practices, and safety procedures to maximize uptime and efficiency.

Frequently asked questions

  • What is the Liebert DCE Rack System? The Liebert DCE Rack System is a modular data center enclosure designed to support flexible configurations, scalable growth, and integrated cooling and power options for reliable, high-density IT deployments. It is built to simplify deployment, streamline maintenance, and optimize overall data center efficiency while offering secure access and durable construction.
  • Which environments is it best suited for? It is well-suited for a range of environments, from edge locations requiring compact, rapidly deployable racks to enterprise data centers needing standardized, scalable enclosures that support evolving workloads and strict service levels. Its modularity and compatibility with Liebert cooling and power ecosystems make it versatile across many verticals.
  • Can I choose pre-configured options or customize my rack? Yes. The Liebert DCE Rack System supports both pre-configured rack selections for quick deployment and fully customized configurations to satisfy site-specific constraints, delivery schedules, and unique equipment needs. This flexibility helps shorten lead times while maintaining alignment with technical and operational requirements.
  • What about maintenance and upgrades? The enclosure is designed for easy serviceability, with accessible panels, modular components, and clear labeling. Regular maintenance can be performed with minimal downtime, and upgrades can be planned around existing workloads due to its scalable architecture and standardized interfaces.
  • Where can I find exact specifications? Exact specifications (dimensions, weight, load ratings, airflow characteristics, and accessory compatibility) are available in the official product listing on ec.synnex.com. Use the product UPC or SKU as reference to pull the official spec sheet from the site.

Customer reviews

(0)

0 Out of 5 Stars


5 Stars
0
4 Stars
0
3 Stars
0
2 Stars
0
1 Star
0


Showing - Of Reviews


You may also like

Recently viewed