Liebert GXT4 3000VA Rack/Tower UPS

LiebertSKU: 5513188

Price:
Sale price$3,268.01

Description

Liebert GXT4 3000VA Rack/Tower UPS

The Liebert GXT4 3000VA Rack/Tower UPS is a true online uninterruptible power supply designed to protect critical IT infrastructure with continuous, high-quality power. Engineered for reliability in data centers, server rooms, and remote offices, this unit delivers seamless, no-break transfer to battery and defends connected equipment against the full spectrum of power disturbances. It is explicitly designed to meet the needs of modern IT environments, offering flexible deployment in rack or tower configurations, and is TAA-compliant for government procurement and other enterprise projects that demand durable, dependable power protection. With a scalable form factor and a focus on stability, the Liebert GXT4 helps maintain uptime for servers, storage devices, networking gear, virtualization hosts, and critical telecommunications equipment, even when the grid is unreliable or fluctuating. In short, it is built to keep mission-critical workloads online, protect data integrity, and simplify the path to rapid recovery after outages while fitting neatly into a wide range of IT footprints.

  • Uninterrupted online power for critical IT workloads: The Liebert GXT4 employs true online protection to deliver a continuous, clean sine wave to every connected device. This means there is no transfer-time delay when switching from utility power to battery, ensuring servers, storage arrays, and networking gear stay online during outages or voltage disturbances. The result is minimized risk of data loss, fewer abrupt shutdowns, and smoother maintenance windows, even during dynamic load changes or poor-quality mains.
  • Flexible rack- and tower-ready installation: Designed for versatility, the GXT4 can be mounted in a standard 2U rack profile or used as a freestanding tower. Its form-factor flexibility supports evolving data-center layouts and space-constrained environments. With straightforward, tool-free conversion between rack and tower configurations, administrators can adapt to shifting footprints without sacrificing uptime or requiring a full equipment swap, delivering long-term value as infrastructure scales.
  • Comprehensive protection against power disturbances: This UPS guards against a broad range of electrical issues that threaten uptime and data integrity—blackouts, brownouts, voltage sags, surges, and noisy electrical environments. By delivering stable, well-regulated power to sensitive IT equipment, the Liebert GXT4 reduces the risk of unexpected outages, prevents equipment stress, and preserves performance during fluctuations in the electrical supply.
  • TAA-compliant and enterprise-grade reliability: Built to meet government and enterprise procurement standards, the Liebert GXT4 is TAA-compliant, ensuring suitability for federal projects and other organizations requiring compliant, durable power protection. Its robust chassis and proven topology are designed for continuous operation in demanding environments, delivering consistent performance across uptime-critical applications while supporting long service life and predictable total cost of ownership.
  • Easy management and scalable runtime options: Management is straightforward via built-in interfaces and standard IT monitoring tools. The GXT4 supports status monitoring, alarm configuration, and graceful shutdowns, ensuring alerting and automated responses align with organizational policies. Runtime can be extended by adding battery modules as workloads grow or as critical infrastructure expands, providing a path to maintain protection without replacing the entire unit.

Technical Details of Liebert GXT4 3000VA Rack/Tower UPS

  • - Get this information from the "specifications" section of the product from https://ec.synnex.com/ using product "UPC" or "SKU" as reference

How to install Liebert GXT4 3000VA Rack/Tower UPS

  • Unpack the unit and verify all components are present, including mounting rails, batteries, cables, and accessories. Inspect for any damage during shipping before proceeding.
  • Choose an installation location with adequate ventilation and clearance for access, cooling, and maintenance. Ensure the area is dry, free of contaminants, and free from excessive heat sources or water exposure.
  • For rack installation, attach the supplied mounting rails to the rack and secure the GXT4 firmly. If you’re placing it in a tower position, place the unit on a stable, level surface with sufficient airflow around all vents.
  • Connect the UPS to a properly grounded wall outlet using the included power cord. Do not use extension cables or power strips that could compromise performance or overload the circuit.
  • Connect critical devices (servers, storage, and networking gear) to the UPS outlets that provide battery-backed protection. Non-critical equipment may be connected to surge-only outlets if available, depending on your model configuration.
  • Attach any management interfaces (USB, serial, or network management card) to your computer or network and install the recommended Liebert monitoring software to enable status monitoring, event logging, and automated shutdowns when necessary.
  • Power on the UPS and perform the built-in self-test to verify battery health and overall operation. Use the LCD display (if equipped) to confirm input/output voltages, load levels, and battery status, and configure sensitivity thresholds and alarms to match your environment.
  • Establish a routine maintenance plan that includes periodic battery health checks and capacity testing. Schedule tests during low-load periods to validate readiness for outages and to verify that automated shutdown procedures initiate correctly when required.

Frequently asked questions

  • Q: What does 3000VA mean for the Liebert GXT4?

    A: The 3000VA rating indicates the apparent power capacity of the UPS. Real-world runtime depends on the actual load attached to the unit. The GXT4 is designed to deliver reliable, continuous online power to protect sensitive equipment during interruptions and fluctuations in the electrical supply.

  • Q: Is the Liebert GXT4 a true online UPS?

    A: Yes. It uses a true online, double-conversion topology to continuously convert incoming AC power to DC and back to AC, providing a clean, regulated output to connected devices regardless of input variations.

  • Q: Can I mount the GXT4 in a rack and also use it as a tower?

    A: Absolutely. The GXT4 supports both rack-mount and tower deployments, enabling flexible placement in data centers, server rooms, and office environments while preserving uptime.

  • Q: What kinds of disturbances does it protect against?

    A: It guards against power outages, brownouts, voltage sags, surges, and electrical noise, helping to preserve data integrity and avoid unexpected device resets during mains issues.

  • Q: How do I monitor the UPS and perform graceful shutdowns?

    A: Use the built-in display and compatible Liebert monitoring software to track status, alarms, and runtime. Configure automated shutdowns for connected servers and network devices when battery levels reach predefined thresholds.

  • Q: Can I extend runtime if needed?

    A: Yes. Runtime can be extended by adding compatible battery modules or external expansion options, allowing you to scale protection to match growing workloads without replacing the entire unit.


Customer reviews

(0)

0 Out of 5 Stars


5 Stars
0
4 Stars
0
3 Stars
0
2 Stars
0
1 Star
0


Showing - Of Reviews


You may also like

Recently viewed