Liebert GXT5 3000VA Rack/Tower UPS

The Vertiv Liebert GXT5 3000VA Rack/Tower UPS is a premium online double-conversion uninterruptible power supply designed to deliver continuous, clean power for critical IT, networking, and data center equipment. This single-phase UPS combines rock-solid protection with flexible deployment, making it ideal for environments where uptime matters—from small data closets to edge locations and hybrid clouds. With a compact 2U footprint that can be rack-mounted or positioned as a tower, the GXT5 3000VA provides reliable power conditioning, sophisticated management features, and scalable runtime to support servers, storage devices, virtualization platforms, and network appliances alike. Its robust design guards against outages, sags, surges, and harmonic distortion, ensuring your loads operate in a stable electrical environment even when the grid falters.

  • Premium online double-conversion power protection: isolates sensitive equipment from input disturbances and delivers a continuous, perfectly conditioned sine-wave output, ensuring peak performance and data integrity during outages and transient events.
  • Flexible rack/tower deployment: a compact, adaptable design that fits into dense data centers or office server rooms, enabling quick installation without compromising space or accessibility.
  • Advanced remote management: built-in monitoring and control capabilities, with USB and RS-232 interfaces and optional Network Management Card support for SNMP, web-based dashboards, asset tracking, and automated safe shutdown across devices.
  • Scalable battery and maintenance features: hot-swappable, user-replaceable battery cartridges and a maintenance bypass option keep critical systems online during service, with the ability to expand runtime through additional battery modules as your load or uptime requirements grow.
  • High reliability with intelligent protection: automatic voltage regulation, surge suppression, overload protection, audible alarms, and an informative LCD display help technicians monitor status, perform self-tests, and plan maintenance with confidence.

Technical Details of Liebert GXT5 3000VA Rack/Tower UPS

  • Power capacity: 3000 VA / 2700 W for robust protection of mid-range server and network deployments.
  • Topology: Online, double-conversion UPS that continuously converts incoming AC to DC and back to AC, delivering a clean, regulated output regardless of input fluctuations.
  • Form factor: Rack/tower convertible with a compact footprint (2U standard footprint) for versatile installation in racks or on floors/benches.
  • Input characteristics: Single-phase input, compatible with standard utility power, with automatic 50/60 Hz sensing to adapt to regional grid frequencies.
  • Output characteristics: 230 VAC nominal (typical in many regions), with tight voltage regulation and a stable 50/60 Hz output to match connected equipment requirements.
  • Battery system: Hot-swappable, maintainable battery cartridges designed for easy replacement and extended service life without powering down protected loads.
  • Runtime options: Runtime is scalable through optional battery modules; total runtime varies with load and configured battery capacity, allowing you to tailor protection to your uptime goals.
  • Management interfaces: USB and RS-232 ports standard; optional Network Management Card enables remote monitoring, SNMP compatibility, and centralized management with compatible software.
  • Protection features: comprehensive protection including surge suppression, short-circuit protection, overload protection, and automatic voltage regulation to keep equipment within safe operating limits.
  • Display and alerts: an intuitive LCD panel provides real-time status, event logs, and actionable guidance; audible alarms alert technicians to faults or mode changes.
  • Installation and services: designed for straightforward deployment with clear front-panel access, standard rack rails, and support for remote maintenance via software tools; compatible with common backup and virtualization platforms for coordinated shutdowns and graceful migrations.

How to install Liebert GXT5 3000VA Rack/Tower UPS

To achieve optimal protection and ease of maintenance, plan the installation around your equipment layout and power architecture. Begin by selecting a location with adequate ventilation, clear airflow, and unobstructed access to ports and maintenance features. If mounting in a rack, install the railkit and secure the UPS with the appropriate screws, ensuring it sits level and stable. For tower configurations, place the unit on a flat, sturdy surface away from heat sources and potential obstructions.

Next, connect the input power from the utility outlet to the UPS input receptacle using an appropriately rated power cord. If you expect high loads or longer cable runs, verify that the selected input wiring matches your regional electrical code and the UPS’s input specifications. Connect your critical devices to the UPS’s output outlets, prioritizing essential systems and ensuring any power distribution equipment is compatible with the unit’s output characteristics.

With the hardware in place, attach the USB and RS-232 cables to your management workstation or server to enable basic monitoring and graceful shutdown capabilities. If you plan to deploy remote management, install the optional Network Management Card and configure SNMP, emails, or web alerts according to your IT policy. Power up the UPS and allow it to initialize; perform the self-test to verify battery health and overall operation.

Configure key settings—output voltage, sensitivity, shutdown thresholds, power-on reset behavior, and load protection policies—using the LCD interface or, where available, the native management software. Establish communication with your virtualization or data protection platform so it can coordinate shutdown sequences and alerts during outages. Finally, document the installation details, including location, load distribution, battery configuration, and maintenance schedule, to simplify future service and audits.

For ongoing reliability, schedule regular battery health checks and self-tests. Periodic testing helps ensure the hot-swappable batteries remain ready to deliver power during an outage and that the maintenance bypass path remains functional for planned service windows. Maintain a small inventory of spare battery cartridges to minimize downtime during battery replacements. Regular firmware updates from Vertiv can also improve performance, compatibility, and security of the management interfaces.

Frequently asked questions

  • What loads should I protect with the Liebert GXT5 3000VA? Protect critical IT infrastructure such as servers, virtualization hosts, storage systems, network switches, routers, and security appliances. The 3000 VA capacity provides headroom for multiple devices under typical enterprise workloads, facilitating graceful shutdowns in outages and protecting against data loss due to sudden power loss.
  • Can I install this UPS in a rack or as a standalone unit? Yes. The Liebert GXT5 is designed for flexible deployment, offering rack-mount compatibility in standard 19-inch racks or a stable tower configuration for spaces without rack access.
  • How can I extend runtime? Runtime is extended through optional battery modules. By adding battery capacity, you can increase uptime at supported loads, allowing longer operations during grid outages or maintenance windows.
  • What management options are available? The UPS includes USB and RS-232 interfaces and supports an optional Network Management Card for remote monitoring, alerting, and centralized control across multi-device environments.
  • Is this UPS suitable for a data center edge deployment? Absolutely. The GXT5’s compact form factor, reliable online power, and flexible management make it well-suited for edge servers, network cabinets, and small data center deployments where space is at a premium and uptime is critical.
  • What maintenance features help with reliability? Features such as hot-swappable batteries, a maintenance bypass path, automatic battery tests, and a clear LCD interface help technicians perform preventive maintenance without disrupting protected loads.