Liebert ITA2-08KMBC40 Bypass Cabinet

LiebertSKU: 5467836

Price:
Sale price$1,243.84

Description

Liebert ITA2-08KMBC40 Bypass Cabinet

The Liebert ITA2-08KMBC40 Bypass Cabinet is a purpose-built, rack-mount solution designed to maximize uptime for business-critical equipment. By providing a dedicated alternate power path, this bypass cabinet enables full isolation of the Liebert ITA2 8kVA UPS during maintenance without interrupting loads connected to the system. Built to endure demanding data center and server room environments, the ITA2 MBC facilitates seamless maintenance windows, reduces planned downtime, and preserves service levels across IT infrastructure. When deployed with the Liebert ITA2 8kVA UPS, it creates a robust, scalable power protection architecture that keeps critical applications online even as components are serviced, upgraded, or replaced. This bypass cabinet integrates smoothly into existing Liebert ITA2 deployments, delivering improved availability, ease of service, and clear operational visibility for facilities teams.

  • Maximized uptime during maintenance — The ITA2-08KMBC40 enables immediate transfer of connected equipment to an alternate power path, preserving power to critical devices while the UPS is isolated for testing, replacement, or upgrade tasks. This means maintenance can be performed without interrupting the loads, helping data centers meet aggressive availability targets and service-level commitments. With a dedicated bypass route, you can schedule maintenance windows with confidence, knowing that critical workloads stay powered and protected throughout the process.
  • Rack-mountable, space-efficient design — Engineered for a 19-inch rack environment, the bypass cabinet integrates cleanly into existing Liebert ITA2 configurations. Its compact footprint and front-access design simplify installation in constrained data centers, edge rooms, or network closets. The solid enclosure provides a secure, organized platform for routing power through the alternate path while maintaining clear separation from the UPS hot side for safety and ease of service.
  • Intuitive operation and clear status — With straightforward controls and status indicators on the front panel, technicians can quickly verify bypass mode, transfer status, and system health. Built to support rapid response during maintenance, the ITA2-08KMBC40 communicates crucial information at a glance, enabling facilities teams to coordinate with IT personnel and avoid unplanned downtime. This emphasis on usability translates into shorter maintenance windows and fewer disruptive troubleshooting steps.
  • Robust safety and compatibility — The cabinet is designed to work in harmony with Liebert ITA2 8kVA UPS systems, ensuring safe isolation and controlled transfer when switching between normal and maintenance paths. The enclosure and interlock features are engineered to meet industry standards for data-center-grade protection, minimizing risk to personnel and equipment during servicing. The result is a safer, more reliable maintenance process that aligns with enterprise power protection strategies.
  • Comprehensive lifecycle support — The ITA2-08KMBC40 bypass cabinet comes with engineering documentation, service compatibility, and access to Liebert support channels for installation planning and ongoing maintenance. By integrating this cabinet into your power protection stack, you gain a scalable path to upgrade or expand your bypass capabilities as your data center grows, while preserving a consistent, familiar maintenance workflow across your Liebert ITA2 ecosystem.

Technical Details of Liebert ITA2-08KMBC40 Bypass Cabinet

  • Application — Bypass cabinet designed for use with Liebert ITA2 8kVA UPS installations to provide a separate maintenance path and full UPS isolation when required.
  • Form factor — Rack-mountable enclosure suitable for standard 19-inch equipment racks, enabling clean integration into existing IT and data-center layouts.
  • Power path — Delivers an alternate power path for connected equipment, allowing uninterrupted operation of critical loads while the UPS is serviced or upgraded.
  • Safety features — Includes interlocks and safe-transfer mechanisms to ensure secure, controlled transitions between normal and bypass modes, reducing the risk of inadvertent power loss.
  • Construction — Rugged steel enclosure designed for data-center environments, with attention to thermal management, accessibility, and ease of service.
  • Compatibility — Specifically engineered for use with Liebert ITA2 8kVA UPS units; aligns with Liebert’s power protection philosophy and maintenance procedures.
  • Indicators — Front-panel indicators provide visibility into bypass status, alarm conditions, and system health for rapid diagnostics.
  • Warranty and support — Backed by Liebert and Schneider Electric’s service networks, with standard product warranties and access to service documentation.

How to Install Liebert ITA2-08KMBC40 Bypass Cabinet

Proper installation of the Liebert ITA2-08KMBC40 Bypass Cabinet is essential to maximize uptime and ensure safe operation. Follow these general steps to add the bypass cabinet to your Liebert ITA2-based power protection system:

  1. Plan and verify compatibility — Confirm that the bypass cabinet is intended for use with your existing Liebert ITA2 8kVA UPS. Review the rack space, mounting points, and electrical connections to ensure a seamless fit within your data-center layout and power distribution scheme.
  2. Prepare the rack and location — Choose a secure, well-ventilated location with adequate clearance for service access. Install the bypass cabinet into a suitable 19-inch rack, align mounting rails, and secure it with appropriate hardware. Ensure that the area is compliant with electrical codes and data-center best practices.
  3. Connect the power paths — Route input power to the bypass cabinet as specified in the installation documentation, ensuring that the alternate path is clearly separated from the UPS output. Connect the loads to the bypass cabinet’s output path as directed, preserving proper phase balance and grounding according to local electrical standards.
  4. Configure and test — After physical installation, configure any required settings on the unit and verify that the bypass transfer mechanism operates correctly. Perform a controlled transfer to the maintenance path and back to normal operation to confirm smooth, interruption-free switching under supervised conditions.
  5. Document and train — Update your facility’s power protection documentation to reflect the addition of the bypass cabinet, including wiring diagrams, transfer procedures, and maintenance schedules. Ensure that facilities and IT staff are trained on the maintenance workflow and safety protocols associated with the bypass path.

Frequently asked questions

  • Q: What is the Liebert ITA2-08KMBC40 Bypass Cabinet?
    A: It is a rack-mountable bypass cabinet designed to work with the Liebert ITA2 8kVA UPS, providing a separate maintenance path and enabling full UPS isolation while loads remain powered.
  • Q: Why would I need a bypass cabinet?
    A: A bypass cabinet allows maintenance on the UPS without interrupting power to the connected equipment. This is critical for data centers and other facilities that require high availability and predictable maintenance windows.
  • Q: Is the bypass cabinet compatible with other UPS models?
    A: The ITA2-08KMBC40 is specifically engineered for use with the Liebert ITA2 8kVA UPS family. Compatibility with other UPS models should be confirmed through official documentation or by consulting Liebert support.
  • Q: What maintenance procedures are supported through the bypass path?
    A: Maintenance tasks such as UPS testing, battery replacement, firmware updates, or component replacements can be performed while loads are on the alternate power path, minimizing downtime.
  • Q: How does the bypass cabinet impact system availability?
    A: By enabling uninterrupted load power during UPS maintenance, the bypass cabinet significantly improves overall availability and reduces scheduled downtime for critical IT equipment.
  • Q: What installation steps are essential for safe operation?
    A: Ensure proper rack mounting, correct wiring of input and bypass paths, verification of transfer operations, adherence to local electrical codes, and comprehensive documentation and staff training.
  • Q: What kind of support is available after installation?
    A: You can access Liebert/SCHNEIDER ELECTRIC support resources, including installation guides, service manuals, warranty information, and technical help to address any operational questions or maintenance needs.