Liebert ITA2 10KVA Tower/Rack Mountable UPS

The Liebert ITA2 10KVA Tower/Rack Mountable UPS is a compact, versatile uninterruptible power supply designed to safeguard your most critical IT assets. Built around true online, double-conversion technology, this UPS continuously conditions and regulates output voltage to deliver a clean, stable power signal to microcomputers, servers, networking gear, and storage devices—even amid fluctuating input power, voltage sags, or brief outages. With a footprint that fits neatly into small data closets, edge deployments, or network rooms, the ITA2 blends performance with flexibility, so you can deploy now and scale later without replacing the unit.

At its core, the ITA2 delivers a highly regulated sine-wave output that remains resilient under diverse load conditions. This means fewer unexpected reboots, reduced risk of data loss, and improved reliability for virtualization hosts, database servers, and mission-critical applications. The online double-conversion topology isolates sensitive equipment from upstream disturbances, providing instantaneous transfer to battery power and a clean handoff back to utility power when the input recovers. This capability is essential for environments that cannot tolerate voltage sags or interruptions, including small to mid-size data centers, corporate IT rooms, remote campuses, and telecom closets.

Beyond power conditioning, the ITA2 is designed for practical deployment in real-world environments. It is tower- or rack-mountable, letting you tailor the physical deployment to your space: start with a compact tower in a small equipment room or data closet, and transition to a standard 19-inch rack with a rail kit as rack density grows. The UPS supports scalable runtime with external battery cabinets, enabling you to meet specific backup time requirements without sacrificing space or adding redundant equipment. Internally, intelligent battery management monitors temperature, discharge rates, and capacity to optimize battery life and ensure a reliable switchover when the grid drops out or dips below acceptable voltage levels.

The ITA2 goes beyond power delivery with robust monitoring and management capabilities. It provides built-in interfaces such as USB and RS-232 for local monitoring, along with options for remote management interfaces that integrate with DCIM tools and network management systems. This enables proactive alerts, automated shutdowns for connected servers during extended outages, and centralized control for facilities teams. For edge deployments or network closets, this level of visibility translates into faster mean time to repair, clearer capacity planning, and improved service continuity for critical business applications.

Engineers and IT professionals will appreciate features like automatic voltage regulation (AVR), which compensates minor fluctuations without drawing from the battery, thereby extending runtime for more meaningful outages. The ITA2 is engineered for reliability and ease of maintenance, with components arranged for straightforward replacement, a maintenance bypass option to service the UPS without powering down connected equipment, and a design that minimizes heat output and noise for office-friendly operation. With a strong emphasis on energy efficiency, this model is well-suited to modern facilities that value lower operating costs and reduced environmental impact while maintaining peak performance for essential infrastructure.

In practice, the Liebert ITA2 10KVA UPS delivers peace of mind for a wide range of workloads. It protects virtualization hosts, file servers, and database servers from power disturbances, while also safeguarding networking devices like switches, routers, and firewalls that form the backbone of your IT ecosystem. For small enterprises embarking on digital transformation or expanding their on-premises footprint, the ITA2 provides a reliable, scalable foundation for uptime and data integrity. It’s equally at home in a regulated healthcare environment or a retail IT room, where downtime can translate into lost revenue or compromised patient or customer data. By combining a compact form factor with the flexibility to scale, the ITA2 makes it possible to design a resilient power infrastructure that grows with your business needs.

Whether you’re migrating toward hybrid cloud, supporting a virtualization stack, or protecting edge computing workloads, the Liebert ITA2 10KVA Tower/Rack Mountable UPS is engineered to deliver consistent performance, predictable runtimes, and intuitive management. Its blend of advanced power conditioning, adaptable mounting options, and scalable runtime makes it a compelling choice for organizations that demand reliability without overbuilding their data footprint. With Vertiv’s focus on reliability and serviceability, the ITA2 stands as a practical, long-term investment for protecting critical IT gear and ensuring continuity in the face of power disturbances.

  • The ITA2 employs true online, double-conversion technology to continuously condition and regulate output voltage, delivering pristine, regulation-ready power to sensitive IT equipment even when input power fluctuates or drops out.
  • Flexible mounting options let you choose between a space-saving tower or a standard 19" rack installation, with easy conversion as your infrastructure evolves and density increases.
  • Scalable runtime supports adding external battery cabinets to meet your exact backup-time requirements, while intelligent battery management ensures long, healthful battery life and predictable UPS performance.
  • Comprehensive monitoring and management capabilities include USB and RS-232 interfaces, with optional network management capabilities for SNMP/web access, enabling proactive alerts and centralized control across multiple devices.
  • Designed for reliability and efficiency, the ITA2 features AVR, hot-swappable maintenance options, and robust protection against surges, sags, and outages, making it suitable for servers, networking gear, storage, and other mission-critical IT components.

Technical Details of Liebert ITA2 10KVA Tower/Rack Mountable UPS

  • Model: Liebert ITA2 10KVA Tower/Rack Mountable UPS
  • Rating: 10 kVA / 9 kW (0.9 power factor typical)
  • Topology: Online double-conversion (VFI) UPS for continuous power conditioning
  • Form factor: Tower and rack-mount convertible; supports standard 19" racks with mounting kit
  • Input: Auto-sensing input suitable for 50/60 Hz environments; compatible with common utility voltages
  • Output: Regulated sine-wave output with selectable voltages (typical options include 120/208/230 VAC) and 50/60 Hz
  • Efficiency: High-efficiency operation typical of online UPS designs, with reduced heat and energy waste
  • Battery: Internal battery pack options with support for external battery cabinets; hot-swappable batteries for maintenance without downtime
  • Monitoring/communication: USB and RS-232 interfaces; optional network management interface for SNMP/web access and centralized monitoring
  • Protection and features: Automatic Voltage Regulation (AVR), surge and short-circuit protection, battery health monitoring, proficient overload protection, maintenance bypass capability

How to install Liebert ITA2 10KVA Tower/Rack Mountable UPS

  • Plan your deployment by choosing the mounting orientation first: a stable tower on the floor or a secure 19" rack installation using the provided rails and mounting kit.
  • Unbox and inspect the unit for any transit damage. Verify all accessories, mounting hardware, and cables are present before installation.
  • Place the UPS in a well-ventilated area with ample clearance for cooling and service access. Ensure the environment is clean, dry, and within the manufacturer’s operating specifications.
  • Connect the input power cable to a dedicated circuit that matches the UPS’s input requirements. Do not load the UPS with other devices on the same circuit during startup to prevent nuisance trips.
  • Mount the UPS in the selected configuration and secure it. Attach the load cables to the UPS’s output terminals, connecting critical devices such as servers and network gear that require uptime protection.
  • Power on the device and navigate the built-in display to perform a basic self-test. Review the status indicators for battery health, load level, and input/output status.
  • Configure operational settings: voltage select, automatic start when utility power returns, and critical-load shutdown triggers for connected equipment. Set up notification channels via USB/RS-232 or the optional network management interface.
  • Install and connect external battery cabinets if a longer runtime is required. Route any expansion cabling to the appropriate connector points and verify that the batteries are properly recognized by the UPS software.
  • Run a scheduled self-test and a practical outage simulation (only in a controlled environment) to validate the switchover behavior and ensure all connected devices respond correctly to a loss of utility power.
  • Document the installation: record the model, serial numbers, firmware versions, and configuration settings. Maintain updated diagrams for facilities and IT teams to coordinate future maintenance and potential escalations.

Frequently asked questions

  • Q: What workloads is the Liebert ITA2 10KVA best suited for?
    A: It protects critical IT equipment such as servers, virtualization hosts, storage arrays, and network infrastructure in small to mid-sized data centers, edge deployments, and network rooms where uptime is essential.
  • Q: Can I convert from a tower to a rack configuration without replacing the UPS?
    A: Yes. The ITA2 is designed to be tower- and rack-mountable with a mounting kit, allowing seamless conversion as your space and density requirements evolve.
  • Q: How can I extend runtime beyond the internal battery capacity?
    A: You can add external battery cabinets designed for Liebert ITA2 runtimes. Runtime scales with the number of battery packs in use and the load served by the UPS.
  • Q: What management options are available for monitoring the UPS?
    A: The ITA2 includes USB and RS-232 interfaces by default, with options for an additional network management interface to enable SNMP or web-based monitoring and alerts across multiple devices.
  • Q: What maintenance considerations should I plan for?
    A: Regularly monitor battery health, perform battery calibrations as recommended, and schedule maintenance bypass procedures during battery servicing. Hot-swappable batteries allow maintenance without powering down the protected equipment.