Description
Liebert ITA2 30kVA Rack/Tower UPS
Engineered for reliability and efficiency, the Liebert ITA2 30kVA Rack/Tower UPS delivers seamless power protection for modern IT environments. Featuring true online double-conversion technology, a unity power factor, and an exceptionally compact rack-tower footprint, this UPS is purpose-built to safeguard critical equipment in computer rooms, data centers, storage facilities, and network closets. It provides a pristine, continuous power supply to protect servers, storage arrays, switches, and other network gear from outages, brownouts, and electrical disturbances, helping preserve data integrity, uptime, and service availability. With a design that supports flexible deployment—from dense rack rows to standalone installations—it scales with your growing IT loads while simplifying maintenance and serviceability. Whether you’re refreshing a single rack or expanding to larger, more complex IT environments, the ITA2 offers robust protection, efficient operation, and a space-saving solution that aligns with modern data center strategies focused on reliability, efficiency, and total cost of ownership.
- True online double-conversion protection for pristine power The ITA2 continuously converts incoming AC power to DC and back to AC, isolating loads from input fluctuations and delivering a stable, regulated output. This seamless power path minimizes voltage sags, transient disturbances, and harmonic distortions that can jeopardize servers, storage systems, virtualization hosts, and network devices, helping ensure stable performance and data integrity even during grid disturbances.
- Unity power factor maximizes usable capacity With PF = 1.0, the full rated VA is available for connected loads. This means you can power more devices without derating or oversizing the UPS, a crucial advantage in space-constrained data centers where every rack unit counts and dense IT deployments demand reliable, scalable protection.
- Rack-tower versatility in a single, compact design The ITA2 is engineered as a versatile rack-tower UPS, enabling easy integration in standard 19-inch racks while also serving as a free-standing unit for smaller rooms or edge deployments. This flexibility supports evolving data-center layouts and growing IT workloads without requiring separate power solutions for each configuration, simplifying installation and future upgrades.
- Efficient operation reduces cooling and energy costs The online topology, efficient components, and optimized power path deliver high efficiency across a broad load range. This translates to lower heat generation, reduced cooling requirements, and lower operating costs—benefits that compound in busy data centers, server rooms, and edge locations that run around the clock.
- Reliable protection for critical IT workloads and data From databases and virtualized environments to storage arrays and core network infrastructure, the ITA2 shields sensitive equipment from outages, sags, and disturbances. This protection helps maintain application performance, shortens recovery times after power events, and supports business continuity across essential IT services.
Technical Details of Liebert ITA2 30kVA Rack/Tower UPS
- Power rating: 30 kVA (unity power factor means about 30 kW of usable output capacity)
- Topology: True online double-conversion UPS for continuous, clean power
- Form factor: Rack/tower convertible, designed to fit in 19-inch racks or stand-alone installations
- Output waveform: Regulated clean sinewave to protect sensitive IT loads
- Physical footprint: Optimized compact design to maximize rack space in dense environments
How to install Liebert ITA2 30kVA Rack/Tower UPS
- Plan placement in a well-ventilated area with adequate clearance for maintenance and cooling, taking into account accessibility for battery service and hot-swappable components.
- Mount in a standard 19-inch equipment rack or place on a sturdy floor stand designed for rack-tower UPS units, following manufacturer rails and weight guidelines.
- Connect input power to an appropriate distribution path with proper grounding and circuit protection according to local electrical codes and the facility’s protection strategy.
- Route loads to the UPS output, ensuring total connected load does not exceed the 30 kVA rating and that critical devices are connected to the UPS outputs as recommended by Liebert guidelines.
- Ensure batteries are connected and charging; verify software management tools are installed and connected for monitoring, alarms, and health checks.
- Power up the unit and perform a basic commissioning test: verify input/output voltages, transfer times, battery discharge (if required by your policy), and communications with any remote management system.
- Set up monitoring, alarms, and maintenance schedules using Liebert management software or compatible systems to maximize uptime and simplify ongoing administration.
Frequently asked questions
- What environments is the Liebert ITA2 30kVA suitable for? It is designed for computer rooms, data centers, storage facilities, and network closets that require reliable, scalable power protection for critical IT equipment.
- What does unity power factor mean for my loads? A unity PF of 1.0 means the UPS can deliver its full rated output to connected equipment, maximizing usable capacity and reducing the need for derating or oversized UPS units.
- Can the ITA2 be used in rack and tower mode? Yes. The design supports both rack mounting and free-standing deployment, offering flexible installation to fit existing infrastructure and future growth.
- What maintenance is recommended? Routine battery health checks, periodic preventive maintenance, and firmware/software updates help sustain peak performance and reliability.
- Does the ITA2 support energy efficiency? Yes. The online double-conversion topology and optimized components provide high efficiency in real-world operating conditions, helping lower energy costs and thermal load in active data centers.