Liebert ITA2 8kVA Rack/Tower UPS

LiebertSKU: 5467840

Price:
Sale price$7,414.25

Description

Liebert ITA2 8kVA Rack/Tower UPS

The Vertiv Liebert ITA2 8kVA Rack/Tower UPS is a compact, high-performance online power protection solution designed to keep critical IT equipment safe and available. With true online, double-conversion technology, it continuously conditions and stabilizes output voltage, delivering pristine power to servers, storage, networking gear, and microcomputer systems even under fluctuating mains conditions. The ITA2 is purpose-built for flexibility, enabling you to deploy it in a traditional rack or convert it to a tower configuration as your space, load, or data-center strategy evolves. This versatility makes it ideal for data centers, edge deployments, telecom rooms, and office environments where uptime and data integrity matter most. By providing clean, regulated power, the Liebert ITA2 minimizes the risk of unexpected shutdowns, reduces heat generation, and extends the lifespan of sensitive equipment through reliable protection against voltage sags, surges, outages, and electrical noise.

  • True online double-conversion power conditioning: The ITA2 delivers a continuously regulated output voltage, isolated from input disturbances, and fast response to transients. This guarantees clean, stable power to sensitive devices, preventing data corruption, hardware wear, and unexplained reboots that can occur during imperfect utility performance.
  • Flexible rack-tower configuration for dynamic deployments: Start in a standard rack footprint to maximize data-center density, then convert to a tower layout to fit evolving spaces, edge installations, or temporary setups without replacing the UPS. This adaptability simplifies migrations and future-proofing.
  • Reliable battery protection with scalable runtime: Equipped with hot-swappable batteries and the option to add external battery cabinets, the ITA2 supports extended runtimes for longer outages. You can tailor battery capacity to match service level requirements, ensuring graceful shutdowns and continued operation during planned or unplanned events.
  • Intelligent monitoring and management for uptime assurance: A front-panel LCD provides real-time status and diagnostics, while USB and RS-232 ports offer local communication. Optional network management cards enable remote monitoring, alerting, and integration with existing IT management workflows for centralized control and proactive maintenance.
  • Efficient, quiet operation in a compact footprint: Designed to minimize heat output and noise, the ITA2 is well suited for office environments, telecom cabinets, and mid-size data centers where space is at a premium and quiet operation is valued. Its energy-conscious design helps reduce cooling loads while maintaining high protection levels.

Technical Details of Liebert ITA2 8kVA Rack/Tower UPS

  • Topology: Online, double-conversion (true on-line power conditioning delivers a stable output regardless of input fluctuations, ensuring continuous protection for connected loads).
  • Capacity: 8 kVA rated, designed to support typical mid-range IT loads; actual usable output can vary with load type and system PF, so plan around your critical equipment profile and derating guidelines.
  • Form factor: Rack-mountable with tower conversion capability, allowing flexible placement in data centers, labs, or edge environments without compromising performance or accessibility.
  • Input/Output: Auto-sensing input with configurable output voltages to accommodate common IT environments. Edge-friendly design ensures compatibility with a range of power standards and discrete outlets for critical devices.
  • Battery: Lead-acid, hot-swappable battery modules; supports optional external battery cabinets to scale runtime for longer outage protection and higher service level commitments.
  • Monitoring & Communication: User-friendly front-panel LCD for live status, alarms, and self-test results; standard USB and RS-232 interfaces with optional network management card for remote monitoring, SNMP support, and integration with IT management ecosystems.
  • Efficiency & Reliability: Engineered for dependable operation with energy-efficient conversion and robust protection features, maintaining performance while minimizing energy waste and heat generation in diverse environments.
  • Environment & Compliance: Built to operate within typical data-center temperatures and humidity ranges, with compliance considerations for regional standards and safety requirements. The unit is designed to support continuous operation in busy IT rooms while preserving equipment integrity.

How to install Liebert ITA2 8kVA Rack/Tower UPS

  • Plan your installation space by assessing whether a rack or tower configuration best fits your environment. Ensure adequate ventilation, clearance for maintenance, and unobstructed access to cables and maintenance panels.
  • Mounting the unit in a rack: attach the supplied rails, slide the UPS into the rack bay, and secure it with appropriate hardware. Verify level installation and ensure the unit is stable and properly aligned with cable management paths.
  • Positioning in a tower setup: place the UPS on a flat, solid surface with sufficient clearance around the unit for cooling and service access. Use stabilizers or anti-tip measures if needed to prevent movement.
  • Connect the loads and the input power: plug your critical devices into the UPS output outlets, taking care not to exceed its rated capacity. Route cables neatly to avoid airflow obstruction. Connect the UPS input to a dedicated, properly protected circuit according to local electrical codes.
  • Battery installation and commissioning: verify that battery modules or external battery cabinets are correctly connected and secured. Power on the unit, run a built-in self-test from the LCD panel, and confirm that all indicators reflect healthy operation.
  • Configure monitoring and shutdown workflows: attach USB or RS-232 connectors for local monitoring, and install an optional network management card if remote visibility is required. Configure alert thresholds, automatic shutdown rules, and integration with your server virtualization or backup software to ensure graceful outages.

Frequently asked questions

  • Q: What types of loads is the Liebert ITA2 designed to protect? A: It is designed to protect a wide range of critical IT equipment, including microcomputers, servers, storage systems, and networking gear, ensuring continuous operation during power disturbances.
  • Q: Can I deploy this UPS in both rack and tower configurations? A: Yes. The Liebert ITA2 is specifically designed as a rack-tower convertible unit to adapt to changing space constraints and deployment needs.
  • Q: How can I extend runtime when outages are longer than expected? A: You can extend runtime by adding hot-swappable battery modules and/or external battery cabinets. Runtime scales with the number of battery banks and the load connected to the UPS.
  • Q: How do I monitor the UPS and receive alerts? A: The unit includes a front-panel LCD for local monitoring and standard USB/RS-232 interfaces for basic communication. An optional network management card enables remote monitoring, alerting, and integration with your monitoring software.
  • Q: Is the Liebert ITA2 energy-efficient? A: Online, double-conversion UPS systems are designed to deliver reliable power with high efficiency and reduced heat output, helping to lower cooling requirements in data centers and office environments.
  • Q: What environments is it best suited for? A: It is well-suited for data centers, edge computing deployments, telecom rooms, and professional office settings where compact size, flexible deployment, and robust power protection are priorities.

Customer reviews

(0)

0 Out of 5 Stars


5 Stars
0
4 Stars
0
3 Stars
0
2 Stars
0
1 Star
0


Showing - Of Reviews


You may also like