Description
Liebert MicroPOD MBS MP2-115HW 2U Tower/Rack Mountable 12A 15 A
The Liebert MicroPOD MBS MP2-115HW is a compact, mission-critical maintenance bypass switch designed for data centers, server rooms, and IT environments where uptime is non-negotiable. This 2U rack-mountable device blends flexible deployment with robust power management, enabling seamless manual transfer of power to connected equipment during UPS maintenance or service events. With rack-and-tower versatility, high-current capability, and a purpose-built bypass mechanism, the MP2-115HW helps IT professionals minimize downtime, protect critical workloads, and simplify power-distribution management in demanding environments. Its thoughtful design supports clean cable management, quick access for technicians, and reliable operation under load, making it an ideal addition to Liebert’s broader family of power protection products. If your goal is to maintain uninterrupted service while performing UPS replacements, battery checks, or circuit maintenance, the MP2-115HW delivers predictable performance, straightforward operation, and compatibility with Liebert UPS ecosystems.
- Maintenance bypass switch for safe, manual transfer of power to connected equipment during UPS maintenance or servicing, allowing technicians to work without fully powering down essential loads.
- Flexible mounting options in a 2U rack-mountable form factor that fits standard 19-inch racks and also adapts to tower configurations for space-constrained deployments or edge installations.
- High current handling with 12 A continuous capability and a 15 A rating to accommodate typical IT loads and transient surges during maintenance events while preserving power integrity.
- Solid construction designed for data-center environments, featuring rugged chassis, front-accessible controls, and clear labeling to streamline setup, operation, and load management.
- Designed for compatibility within Liebert power protection ecosystems, enabling smooth integration with Liebert UPS systems and related hardware to deliver comprehensive, cohesive power protection.
Technical Details of Liebert MicroPOD MBS MP2-115HW
- Enclosure and mounting: 2U rack-mountable or tower configuration, compatible with standard 19-inch racks.
- Current rating: 12 A continuous with a 15 A maximum rating to support typical server room loads and maintenance scenarios.
- Input voltage: 120 VAC nominal (50/60 Hz) to align with common IT infrastructure power systems.
- Power transfer: Built-in maintenance bypass switch enabling manual transfer of power to connected equipment during UPS service.
- Form factor and connectivity: Compact 2U footprint with front-access controls and clearly labeled outlets for organized deployment.
- Compatibility: Designed to integrate with Liebert UPS systems and related power protection products for unified management and protection.
How to install Liebert MicroPOD MBS MP2-115HW
Installing the Liebert MicroPOD MBS MP2-115HW is a straightforward process that should be performed by qualified personnel following standard data-center safety practices. Begin by planning a location that provides adequate airflow, accessibility, and secure mounting within a standard 19-inch rack. Ensure the installation area is free from excessive dust and moisture, and that power sources and cables are organized to minimize trip hazards and interference with cooling airflow. Gather the appropriate mounting hardware and tools commonly used for 2U rack installations, and verify that the rack rails accommodate the MP2-115HW’s dimensions before starting.
- Mounting preparation: Confirm that the rack space is clear and that the MP2-115HW will fit in a 2U slot with easy access to front-panel controls and cable connections. If you plan to use a tower configuration, ensure stabilizing supports or feet are in place to prevent tipping.
- Rack installation: Attach the MP2-115HW to the rack using the recommended 19-inch mounting brackets and hardware. Tighten fasteners evenly to avoid misalignment, and check that the unit sits securely with no wobble. Maintain adequate clearance around the front and rear panels for ventilation and cable routing.
- Power connections: Connect the MP2-115HW’s input power to the UPS output or appropriate power source per the manufacturer’s guidance. Use properly rated cables and verify that connectors are fully seated. Route cables to minimize bending and ensure they do not obstruct airflow or rack equipment.
- Load connections: Connect the IT equipment to the MP2-115HW’s output outlets according to labeling and load requirements. Group related devices together to simplify maintenance and circuit tracking, and avoid exceeding the 12 A continuous rating for any single outlet or bank of outlets.
- Bypass operation readiness: Familiarize yourself with the maintenance bypass switch controls and indicators. Before connecting critical loads, perform a zero-load or low-load check to verify that the bypass path engages correctly and that the load transfers as intended when isolating the UPS for service.
- Documentation and labeling: Label power paths, UPS connections, and circuit mappings so future technicians can quickly identify the bypass path and load distribution. Keep an updated diagram in the data-center asset catalog for ongoing maintenance planning.
- Final checks and testing: Power up the system, monitor indicators, and confirm normal operation under load. Perform a controlled bypass transfer test following the UPS manufacturer’s guidelines to ensure the MP2-115HW reliably transfers power without interrupting critical equipment.
Frequently asked questions
- What is the Liebert MicroPOD MBS MP2-115HW? It is a maintenance bypass switch designed to enable safe, manual transfer of power from a Liebert UPS to connected equipment during maintenance or servicing, minimizing downtime and preserving data integrity.
- What are the power specifications? The MP2-115HW supports up to 12 A continuous operation with a 15 A rating, suitable for typical server and network gear loads in many data-center environments. It operates with a nominal 120 VAC input (50/60 Hz).
- Is it rack-mountable? Yes. The MP2-115HW is designed as a 2U rack-mountable unit that also can be configured for tower deployment, providing flexible installation options in data centers, edge facilities, and IT closets.
- What makes it compatible with Liebert UPS systems? The MicroPOD MP2-115HW is engineered to integrate with Liebert power protection products, enabling cohesive power management and protection across the UPS, bypass, and connected equipment ecosystem.
- How do I install and test the bypass? Install the unit in a suitable rack location, connect power and loads per labeling, secure all cables, and perform a controlled bypass transfer test following the UPS manufacturer’s guidelines to confirm proper operation without affecting critical workloads.
- Who should install this device? Qualified data-center technicians or IT engineers with experience in rack-mount power distribution and UPS maintenance should handle installation and testing to ensure safety and compliance with local electrical codes.
Customer reviews
Showing - Of Reviews