Liebert PD2-201 integrated output distribution (2) IEC320-C19; (8) IEC320-C13 outputs

LiebertSKU: 5467506

Price:
Sale price$440.12

Description

The Liebert PD2-201 integrated output distribution (POD) from Vertiv is a purpose-built power distribution solution designed to work seamlessly with Liebert GXT4 8-10kVA and GXT5 16-20kVA UPS systems. This POD unit combines robust output distribution, a built-in maintenance bypass, and a compact, rugged design to enhance reliability, uptime, and serviceability in data centers, server rooms, and critical IT environments. By enabling maintenance or component replacement without interrupting loads, the PD2-201 minimizes downtime and maximizes availability for sensitive equipment, making it an essential addition to modern power protection architectures.

  • Uninterrupted UPS maintenance with built-in maintenance bypass - The maintenance bypass feature allows you to perform UPS servicing or component replacement without taking connected loads offline, preserving uptime and reducing risk during maintenance windows.
  • Flexible output configuration: (2) IEC320-C19 and (8) IEC320-C13 outlets - This mixed-output arrangement supports high-demand servers, networking gear, and peripheral devices, delivering scalable distribution while preserving outlet flexibility.
  • Optimized integration with Liebert GXT4/GXT5 UPS models - Engineered to complement the performance characteristics of these UPS families, the POD ensures proper load distribution, electrical compatibility, and simplified commissioning.
  • Comprehensive protection and status visibility - Integrated protection features plus easy-to-read indicators help you monitor voltage, load, and fault conditions, enabling proactive maintenance and rapid response to anomalies.
  • Rugged, space-efficient design for datacenter environments - Built to withstand demanding environments, the PD2-201 fits into standard rack footprints while delivering dependable power distribution in constrained spaces.

The PD2-201 acts as a critical interface between your UPS and the data center rack equipment. By consolidating distribution and bypass capabilities into a single, purpose-built unit, it reduces complexity and helps maintain continuous protection for essential IT infrastructure. The combination of IEC320-C19 and IEC320-C13 outlets supports a wide range of devices, from high-wattage servers and storage systems to networking gear and peripherals, allowing you to tailor the POD to your specific load profile. This product is especially valuable in environments requiring fast maintenance cycles, tight change control, and a strong emphasis on high availability.

Beyond basic distribution, the PD2-201 contributes to overall energy efficiency and thermal management within data center environments. With a streamlined path of power from the UPS to critical equipment, losses are minimized, and the risk of ripple or arcing is reduced through reliable contact points and quality connectors. The integrated design also simplifies cable management, enabling neater installations and easier future upgrades. Supported by Vertiv's reputation for reliability, the PD2-201 is a prudent investment for organizations seeking to balance performance, safety, and long-term total cost of ownership.

When planning deployment, consider how the PD2-201 will integrate with your rack layout, cooling strategy, and maintenance windows. The unit's outputs are configured to maximize the utility of available outlets while preserving the ability to isolate and service the UPS without affecting critical loads. This approach aligns with best practices for high-availability environments, helping you meet service-level agreements (SLAs) and minimize unplanned outages. The PD2-201 is more than a power strip; it is a carefully engineered component of a resilient power protection ecosystem.

For IT teams, the POD simplifies operational procedures. Clear labeling, straightforward wiring, and compatibility with common UPS models translate into faster installation, easier audits, and fewer wiring errors. The built-in maintenance bypass reduces the need for external bypass modules, saving space and reducing the number of single points of failure in the power distribution chain. With the PD2-201, you can organize your power distribution in a way that supports scalable growth, allowing you to add devices as your IT footprint expands while maintaining predictable and reliable power delivery.

In summary, the Liebert PD2-201 integrated output distribution unit combines essential features—built-in maintenance bypass, multiple outlet configurations, UPS compatibility, protective features, and a compact form factor—into a comprehensive solution for modern data centers and critical IT environments. It is an ideal choice for organizations that demand high availability, straightforward maintenance, and efficient, reliable power distribution that works in concert with their Liebert UPS investments.

Technical Details of Liebert PD2-201

  • Output configuration: (2) IEC320-C19 outlets and (8) IEC320-C13 outlets for flexible connection of high- and standard-power devices.
  • Maintenance bypass: built-in, enabling UPS servicing without interrupting connected loads.
  • Intended UPS compatibility: designed for use with GXT4 8-10kVA and GXT5 16-20kVA UPS models.
  • Protection and monitoring: integrated protections and status indicators to help monitor load, voltage, and fault conditions.
  • Form factor and design: rugged, space-efficient POD suitable for rack-mount deployments in data centers and critical IT spaces.
  • Reliability focus: engineered to deliver consistent power distribution with minimal downtime during maintenance cycles.

How to install Liebert PD2-201

  • Confirm compatibility: verify that your UPS model (GXT4 8-10kVA or GXT5 16-20kVA) is intended to work with the PD2-201 POD and that the rack space is suitable for installation.
  • Power down procedure: follow your facility’s safe shutdown protocols and disconnect power to the equipment that will be connected to the POD, if required by your maintenance plan.
  • Mounting and mounting orientation: install the PD2-201 in an appropriate rack position, ensuring ventilation and clearance for cables and heat dissipation; secure mounting hardware per your data center standards.
  • Wiring the outputs: connect the 2 IEC320-C19 outlets to devices with higher power draws and the 8 IEC320-C13 outlets to standard equipment, following labeling and color-coding conventions to avoid miswiring.
  • Connecting the POD to the UPS: route power and control connections according to the UPS and POD manuals, ensuring proper alignment of bypass and distribution pathways.
  • Maintenance bypass activation: configure and test the built-in maintenance bypass to confirm that it can sustain loads during UPS servicing without interrupting uptime.
  • Load balancing and verification: verify that the total connected load remains within the POD’s design tolerances and check that all devices power on correctly after installation.
  • Documentation and testing: update facility drawings and run a planned test of the bypass and redistribution to ensure operational readiness and to validate alarm and status signals.

Frequently asked questions

  • Q: What outlets are included on the Liebert PD2-201? A: The unit provides (2) IEC320-C19 outlets and (8) IEC320-C13 outlets for flexible device connectivity.
  • Q: Does the PD2-201 require a separate maintenance bypass module? A: No. The maintenance bypass is built into the PD2-201, enabling service work without interrupting protected loads.
  • Q: Which UPS models is the PD2-201 designed to work with? A: It is designed for use with Liebert GXT4 8-10kVA and GXT5 16-20kVA UPS systems, ensuring compatible power distribution and control.
  • Q: Can the PD2-201 be mounted in a data center rack? A: Yes. The POD is designed for rack-mount deployment in data centers and similar environments, with a compact, rugged enclosure suitable for heavy-use spaces.
  • Q: What maintenance benefits does the PD2-201 offer? A: It enables maintenance activities on the UPS without interrupting the connected loads, minimizing downtime, reducing risk during servicing, and simplifying change control for IT environments.