Description
The Liebert PD2-204 integrated output distribution (POD) is a purpose-built power distribution solution designed to optimize reliability and uptime for Vertiv Liebert UPS systems. Specifically engineered for use with GXT4 8-10kVA and GXT5 16-20kVA UPS models, this POD unit provides a streamlined path to maintain electrical availability while performing UPS maintenance or component replacements. With its built-in maintenance bypass, the PD2-204 enables service personnel to perform essential work without interrupting critical loads, delivering continuity for data centers, network closets, and edge environments.
- Maintenance without downtime: The built-in maintenance bypass feature lets you service or replace UPS components without powering down connected equipment, reducing risk and downtime.
- Flexible outlet configuration: Four IEC320-C13 outlets provide standard appliance and IT load connections, while two IEC309-32A outputs handle heavier, high-current circuits with confidence.
- Compact, robust POD design: Engineered to pair seamlessly with Liebert GXT4 and GXT5 UPS systems, the PD2-204 delivers dependable load distribution in compact rack or cabinet footprints.
- Safety and reliability by design: The POD’s integrated protection, status indicators, and protected wiring path contribute to safer operation and easier maintenance workflows.
- Ideal for mission-critical environments: Whether supporting data centers, telecom rooms, or enterprise IT closets, the PD2-204 helps keep essential equipment running during UPS service events.
Technical Details of Liebert PD2-204
- Outlets: 4 IEC320-C13 (standard IT load connections)
- Outlets: 2 IEC309-32A (heavy-duty high-current outputs)
- Built-in maintenance bypass to facilitate UPS maintenance without interrupting power to critical loads
- Designed for compatibility with GXT4 8-10kVA and GXT5 16-20kVA UPS models
- Integrated power distribution for safe, organized routing of downstream equipment
- Compact, rack-mountable form factor suitable for data centers, network rooms, and edge deployments
- Enhanced protection and monitoring features to support reliable operation and quick fault diagnosis
How to Install Liebert PD2-204
Installing the Liebert PD2-204 is a straightforward process designed to minimize downtime and simplify integration with existing Liebert UPS configurations. Follow these general steps to deploy the POD effectively in your environment:
- Prepare the installation area: Ensure adequate space for access, ventilation, and cable management near the UPS and the equipment the POD will serve.
- Power down the UPS and connected load as directed by your facility’s safety protocols before starting installation.
- Mount the PD2-204 in the designated rack or cabinet location according to your data center standards and the POD’s mounting guidelines.
- Connect the PD2-204 input feed to the appropriate UPS output or the designated power source per the wiring diagram supplied by Vertiv for the GXT4/GXT5 integration.
- Route and connect the four IEC320-C13 outlets to standard IT equipment and the two IEC309-32A outlets to higher-current circuits as required by your load profile.
- Verify the maintenance bypass operation by following the product documentation, ensuring that bypass components are accessible and testable without disrupting critical loads.
- Power up the system and monitor status indicators to confirm proper operation and load distribution across all outlets.
- Document the wiring configuration and test procedures for ongoing maintenance and future upgrades.
Frequently Asked Questions
- What is the Liebert PD2-204? A POD (power output distribution) unit with built-in maintenance bypass, designed to work with Vertiv Liebert GXT4 and GXT5 UPS systems to allow maintenance or replacement without interrupting critical loads.
- Which outlets are included? The PD2-204 provides 4 IEC320-C13 outlets for standard IT loads and 2 IEC309-32A outlets for higher-current circuits.
- How does the maintenance bypass improve uptime? The bypass lets technicians perform UPS maintenance or component replacement while the critical loads remain powered, reducing downtime and risk.
- Is the PD2-204 compatible with GXT4 and GXT5 UPS models? Yes, it is specifically designed for compatibility with GXT4 8-10kVA and GXT5 16-20kVA UPS models.
- What environments is it best suited for? Data centers, enterprise IT rooms, telecom closets, and edge computing installations that require reliable power distribution with maintenance capabilities.