Liebert PD2-204 integrated output distribution with 4 IEC320-C13; 2 IEC309-32A outputs

LiebertSKU: 5467509

Price:
Sale price$540.94

Description

The Liebert PD2-204 integrated output distribution (POD) is a purpose-built power distribution solution designed to optimize reliability and uptime for Vertiv Liebert UPS systems. Specifically engineered for use with GXT4 8-10kVA and GXT5 16-20kVA UPS models, this POD unit provides a streamlined path to maintain electrical availability while performing UPS maintenance or component replacements. With its built-in maintenance bypass, the PD2-204 enables service personnel to perform essential work without interrupting critical loads, delivering continuity for data centers, network closets, and edge environments.

  • Maintenance without downtime: The built-in maintenance bypass feature lets you service or replace UPS components without powering down connected equipment, reducing risk and downtime.
  • Flexible outlet configuration: Four IEC320-C13 outlets provide standard appliance and IT load connections, while two IEC309-32A outputs handle heavier, high-current circuits with confidence.
  • Compact, robust POD design: Engineered to pair seamlessly with Liebert GXT4 and GXT5 UPS systems, the PD2-204 delivers dependable load distribution in compact rack or cabinet footprints.
  • Safety and reliability by design: The POD’s integrated protection, status indicators, and protected wiring path contribute to safer operation and easier maintenance workflows.
  • Ideal for mission-critical environments: Whether supporting data centers, telecom rooms, or enterprise IT closets, the PD2-204 helps keep essential equipment running during UPS service events.

Technical Details of Liebert PD2-204

  • Outlets: 4 IEC320-C13 (standard IT load connections)
  • Outlets: 2 IEC309-32A (heavy-duty high-current outputs)
  • Built-in maintenance bypass to facilitate UPS maintenance without interrupting power to critical loads
  • Designed for compatibility with GXT4 8-10kVA and GXT5 16-20kVA UPS models
  • Integrated power distribution for safe, organized routing of downstream equipment
  • Compact, rack-mountable form factor suitable for data centers, network rooms, and edge deployments
  • Enhanced protection and monitoring features to support reliable operation and quick fault diagnosis

How to Install Liebert PD2-204

Installing the Liebert PD2-204 is a straightforward process designed to minimize downtime and simplify integration with existing Liebert UPS configurations. Follow these general steps to deploy the POD effectively in your environment:

  • Prepare the installation area: Ensure adequate space for access, ventilation, and cable management near the UPS and the equipment the POD will serve.
  • Power down the UPS and connected load as directed by your facility’s safety protocols before starting installation.
  • Mount the PD2-204 in the designated rack or cabinet location according to your data center standards and the POD’s mounting guidelines.
  • Connect the PD2-204 input feed to the appropriate UPS output or the designated power source per the wiring diagram supplied by Vertiv for the GXT4/GXT5 integration.
  • Route and connect the four IEC320-C13 outlets to standard IT equipment and the two IEC309-32A outlets to higher-current circuits as required by your load profile.
  • Verify the maintenance bypass operation by following the product documentation, ensuring that bypass components are accessible and testable without disrupting critical loads.
  • Power up the system and monitor status indicators to confirm proper operation and load distribution across all outlets.
  • Document the wiring configuration and test procedures for ongoing maintenance and future upgrades.

Frequently Asked Questions

  • What is the Liebert PD2-204? A POD (power output distribution) unit with built-in maintenance bypass, designed to work with Vertiv Liebert GXT4 and GXT5 UPS systems to allow maintenance or replacement without interrupting critical loads.
  • Which outlets are included? The PD2-204 provides 4 IEC320-C13 outlets for standard IT loads and 2 IEC309-32A outlets for higher-current circuits.
  • How does the maintenance bypass improve uptime? The bypass lets technicians perform UPS maintenance or component replacement while the critical loads remain powered, reducing downtime and risk.
  • Is the PD2-204 compatible with GXT4 and GXT5 UPS models? Yes, it is specifically designed for compatibility with GXT4 8-10kVA and GXT5 16-20kVA UPS models.
  • What environments is it best suited for? Data centers, enterprise IT rooms, telecom closets, and edge computing installations that require reliable power distribution with maintenance capabilities.