Description
Liebert PSI 2200VA Line-Interactive Rack/Tower UPS
The Liebert PSI 2200VA Line-Interactive Rack/Tower UPS from Vertiv is a compact, dependable power protection solution designed for IT environments that require reliable uptime without sacrificing space or flexibility. Built to shield servers, network switches, routers, storage appliances, and other critical equipment, this UPS delivers clean, regulated power even when the grid fluctuates. Its versatile rack and tower form-factor makes it a perfect fit for network closets, small data centers, edge deployments, and home lab setups, ensuring critical devices stay online during outages and power anomalies.
With a line-interactive topology and automatic voltage regulation, the Liebert PSI-2200VA stabilizes voltage levels without unnecessary battery use. That means you enjoy protected runtime when you need it and efficient power use when you don’t. The device is engineered for quiet operation and reliable performance in tight spaces, combining smart battery management with simple, user-friendly monitoring options. Whether you’re safeguarding a single server, a small stack of network gear, or a multi-device lab setup, the PSI 2200VA provides consistent, dependable backup power when it matters most.
Designed for efficiency and reliability, the Liebert PSI 2200VA helps IT teams meet uptime SLAs without sacrificing space or budgets. Its compact footprint and intelligent design minimize heat and noise, making it suitable for office environments, data closets, and edge locations where space is at a premium. The UPS is built to endure the rigors of daily operation, with robust chassis construction, intuitive diagnostics, and scalable protection that grows with your infrastructure. Whether you’re protecting a single rack-width server or a small network rack, the PSI 2200VA delivers dependable performance when it counts most.
- Reliable protection for essential IT gear: Safeguards servers, network workstations, switches, routers, storage devices, and other critical nodes from outages, surges, sags, and harmonics that can disrupt operations or damage hardware.
- Line-interactive technology with AVR: Automatic voltage regulation corrects minor power fluctuations on the incoming supply, reducing wear on batteries and extending runtime for connected devices.
- Flexible mounting for rack or tower deployments: Converts easily between a standard rack enclosure or a free-standing tower, so you can place it where your equipment lives without compromising space or accessibility.
- Accessible management and monitoring: USB and serial connectivity, plus audible alarms and status indicators provide quick visibility into battery health, load, and system status; compatible management software supports graceful shutdowns and remote monitoring in small networks.
- Efficient battery management and reliability: Thoughtful charging and self-test routines preserve battery life, maximize runtime when needed, and simplify maintenance in busy IT environments.
Technical Details of Liebert PSI 2200VA Line-Interactive Rack/Tower UPS
- Topology: Line-interactive UPS with automatic voltage regulation for stable output during brownouts and sags.
- Form factor: Rack/tower convertible to fit a variety of installations and spaces.
- Power rating: 2200 VA capacity to support multiple devices and moderate workloads.
- Output options: Provides regulated AC output to connected equipment with surge and short-circuit protection.
- Inputs/Controls: Standard input plug(s) suitable for common regional outlets; USB and Serial interfaces for local management; audible alarms and status indicators.
- Battery system: Maintenance-free sealed lead-acid backup battery with built-in charging and self-test features to ensure reliability.
How to install Liebert PSI 2200VA Line-Interactive Rack/Tower UPS
Follow these steps to install and configure your Liebert PSI 2200VA for optimal protection and easy management:
- Step 1: Choose the right orientation and mounting. If using in a rack, install in a standard 19-inch rack enclosure with proper clearance for ventilation. If used as a tower, position on a stable surface away from heat sources and direct sunlight.
- Step 2: Mount or place the unit. Use included rails or brackets to secure the unit in a rack, or simply place it on a shelf or cabinet for tower mode. Ensure adequate airflow around the UPS.
- Step 3: Connect the load. Plug your critical devices—servers, switches, routers, and storage arrays—into the UPS outlets. Do not exceed the unit’s rated output to prevent nuisance tripping.
- Step 4: Connect to power. Plug the UPS into a properly grounded wall outlet using the appropriate regional plug. Avoid extension cords for the primary connection to ensure proper protection and reliable operation.
- Step 5: Establish management and testing. Attach USB or serial cables to a computer for monitoring and safe shutdown, install the recommended management software if available, and run a self-test to verify that the battery and circuitry are functioning as expected.
- Step 6: Configure notifications and shutdown policies. Set up alert preferences and automatic shutdown timing for connected equipment to protect data integrity during outages or extended outages.
- Step 7: Perform regular maintenance. Periodically inspect battery condition, clean dust from vents, and run battery self-tests to confirm ongoing reliability.
Frequently asked questions
- Q: What equipment is best protected by the Liebert PSI 2200VA? A: It is well suited for small IT closets, edge deployments, home labs, and small data centers. It protects servers, network devices, storage, and other critical equipment from power disturbances.
- Q: Does the unit provide protection against surges and outages? A: Yes. The UPS includes surge protection and battery-backed runtime to keep devices online during outages and to guard against power anomalies that can damage equipment.
- Q: How do I monitor the UPS status? A: Connect via USB or Serial and use the bundled software (or your preferred management tool) to monitor battery health, load, runtime, temperature, and event history, and to initiate safe shutdowns when needed.
- Q: Can the UPS be rack-mounted? A: Absolutely. The Liebert PSI 2200VA is designed for rack-mount installation as well as tower deployment, offering flexible installation options for different spaces.
- Q: How do I replace the battery? A: Battery replacement typically involves power-down, disconnecting the UPS from mains, and following manufacturer guidance to remove and replace the sealed lead-acid battery pack. It is recommended that a qualified technician perform battery replacements.
- Q: What is the expected runtime? A: Runtime depends on the connected load. With lighter loads, you can expect longer runtimes, while heavier loads shorten runtime. It’s best to estimate based on your actual device load and refer to the supplier’s runtime charts for typical configurations.