Liebert Standard Power Cord

LiebertSKU: 5467844

Price:
Sale price$1,986.04

Description

The Liebert Standard Power Cord is a purpose-built cable kit designed to simplify installations and servicing for Liebert ITA2 systems. By converting traditional hard-wired connections to cord-n-plug connections, this kit reduces setup time, minimizes field labor, and enhances serviceability in critical power environments. The ITA2-10KMBCSL3 model brings together reliability, safety, and flexibility with components specified for high-current connections, making it an essential accessory for data centers, server rooms, and other applications where uninterrupted power is a priority.

  • Cord-n-plug conversion for easy installation and servicing: Replace hard-wired terminations with plug-style connections to streamline installations and field maintenance, decreasing downtime and labor costs.
  • High-current IEC60309-60A input cords: Two input cords, each 10 ft (3 m) long, equipped with IEC60309-60A connectors to handle demanding power loads safely.
  • Compact main output cord for neat, organized setups: A 1 ft (305 mm) main output cord helps keep cables tidy around equipment, reducing clutter and improving airflow.
  • Designed for Liebert ITA2 configurations: Specifically configured to integrate with Liebert ITA2 systems, ensuring compatibility and optimized performance in critical environments.
  • Durable, field-ready construction: Built to withstand routine servicing and relocation needs, providing dependable operation across a variety of deployment scenarios.

Technical Details of Liebert Standard Power Cord

  • P/N ITA2-10KMBCSL3
  • Includes two input cords, each 10 ft (3 m) long, with IEC60309-60A connectors
  • Includes one main output cord, 1 ft (305 mm) long
  • Cable kit converts standard hard-wired connections to cord-n-plug connections for easier installation and servicing
  • Compatible with Liebert ITA2 systems and related power distribution configurations

How to install Liebert Standard Power Cord

To ensure a safe and effective installation, follow these general steps. Always observe your facility’s safety protocols and any manufacturer guidelines specific to your Liebert ITA2 setup.

  • Power down the equipment and disconnect from all power sources before beginning installation to prevent electric shock or equipment damage.
  • Inspect the IEC60309-60A input connectors on the two 10 ft input cords for any signs of damage or contamination; replace if necessary.
  • Disconnect the existing hard-wired terminations and prepare the connection points on the Liebert ITA2 unit to accept cord-n-plug inputs.
  • Attach each 10 ft input cord to the corresponding input terminals or bus connections on the Liebert ITA2 chassis, ensuring firm, secure contacts and correct polarity as specified by the equipment manual.
  • Connect the main output cord (1 ft) from the designated load or distribution path, routing cables neatly to minimize airflow obstruction and reduce stress on connectors.
  • Tighten any strain-relief fittings and secure all cords to prevent movement or accidental disconnection during operation or servicing.
  • Power up the system and verify that all indicators show normal operation. Conduct a brief functional test to confirm proper cord-n-plug connectivity and load distribution.
  • Document the installation for future maintenance records, including cord lengths, connector types, and P/N (ITA2-10KMBCSL3) to facilitate rapid servicing if needed.

Frequently asked questions

  • Q: What is the Liebert Standard Power Cord used for? A: It converts standard hard-wired connections to cord-n-plug connections for easier installation and servicing on Liebert ITA2 systems.
  • Q: What is included in the ITA2-10KMBCSL3 kit? A: The kit includes two input cords, each 10 ft (3 m) long with IEC60309-60A connectors, and one main output cord, 1 ft (305 mm) long.
  • Q: What connectors are used? A: IEC60309-60A connectors are used on the input cords for high-current, secure connections.
  • Q: Is this kit compatible with Liebert ITA2 systems? A: Yes, it is specifically designed for use with Liebert ITA2 configurations to facilitate cord-based installations and servicing.
  • Q: How does this kit impact maintenance downtime? A: By enabling fast plug-and-play cord connections, technicians can quickly connect or replace cords without re-wiring, reducing downtime and simplifying servicing.